Dold 0054127 IK8839.11 175mA MAX.20A AC220-240V current monitor
|
189,83 EUR |
|||||||||||
|
( 225,90 EUR incl. VAT ) ≈ £158.89 | ≈ $208.62 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002251 | ||||||||||
| Mfg Part No: | 0054127 | ||||||||||
| UPC/EAN: | 4030641541279 | ||||||||||
| Weight: | 0.123 kg | ||||||||||
| Type: | IK8839.11 175mA MAX.20A AC220-240V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0054127:
Applications
The current monitor is primarily designed for monitoring loads with an operating current in the range of 0.175 to 1 A. Typical applications include heating systems in industrial processes, building heating, or in process automation, where continuous functional monitoring is required. The device is intended for use in single-phase systems and operates with an auxiliary voltage of AC 220 to 240 V. Monitoring is performed by measuring the flowing current at inputs i and k, with the switching point fixed at 175 mA.
Functions and Equipment in Detail
The device features a fixed switching point of 175 mA, which triggers when exceeded or undershot. The output contact configuration consists of a changeover contact (1 C/O contact), which can be used to control auxiliary relays or signal indicators. The maximum switching capacity is 20 A at AC 230 V, with overload capability up to 150 A for short durations (2 seconds). The response time is approximately 60 ms, enabling rapid reaction to disturbances. Two LED indicators signal the operating status: the upper LED lights up when auxiliary voltage is applied, and the lower LED when the output relay is activated.
Technology Explained Simply
The current monitor measures the flowing current via inputs i and k and compares it to the fixed switching point of 175 mA. Deviations within the switching tolerance of ±15 % trigger the output changeover contact. The auxiliary voltage is supplied via terminals A1/A2, supporting voltage ranges of AC 220–240 V. The nominal frequency is 50 Hz, with a frequency range of ±5 %. The electrical service life is approximately 100,000 switching cycles at 5 A and 50,000 at 8 A, ensuring high operational reliability. The mechanical service life is 20 million switching operations.
Compatibility and Accessories
The device is designed for mounting on a DIN rail according to IEC/EN 60715. The connection terminals are suitable for conductor cross-sections of 2 x 2.5 mm² (solid) or 2 x 1.5 mm² (stranded wire with ferrule DIN 46228-1/-2/-3/-4). The stripping length is 10 mm, and the tightening torque for the terminals is specified as 0.8 Nm. The switching function is standardized to AC 15, with the make contact rated up to 3 A and the break contact up to 1 A at AC 230 V. The maximum short-circuit withstand requires a fuse of 4 A gG/gL.
Mounting and Installation
Mounting is performed on a DIN rail within the installation distributor. The terminals are equipped with self-release flat terminals, enabling simple and secure connections. The terminal designations are clearly defined: A1/A2 for voltage supply, i/k for current measurement, and 11/12/14 for the changeover contact. The device dimensions and mounting specifications comply with standards IEC/EN 60999-1 and IEC/EN 60715.
Operational Advantages
The IK8839.11 current monitor provides reliable functional monitoring with high overload capacity and long service life. The LED indicators allow for quick visual inspection of the operating status. The compact design with a width of 17.5 mm and DIN rail mounting facilitate integration into existing control systems. Compliance with standard IEC/EN 60255-1 ensures conformity with industrial requirements. Operating temperature ranges from -20 to +60 °C, and storage temperature from -25 to +60 °C, making the device suitable for diverse operating conditions. The enclosure protection rating is IP 40, and the terminals are rated IP 40, protecting against mechanical impacts and contact, although the terminals are not protected against contact.
Standards and Approvals
The device complies with standard IEC/EN 60255-1 for electrical equipment for measurement and monitoring. EMC requirements are met according to IEC/EN 61000-4-2 to -6, including immunity to electrostatic discharge, RF radiation, fast transients, and surge voltages. Radio frequency interference suppression meets Class B limit according to EN 55011. Terminal designation follows EN 50005. The operating altitude is limited to below 2000 m.
Operating Environments
The device is designed for continuous operation and can be operated at ambient temperatures from -20 to +60 °C. Relative humidity must not exceed 93 % at 40 °C. Storage temperature ranges from -25 to +60 °C. Vibration resistance is specified for an amplitude of 0.35 mm and frequencies from 10 to 55 Hz according to IEC/EN 60068-2-6. Climatic resistance corresponds to test 20/060/04 according to IEC/EN 60068-1.
Materials and Construction
The enclosure is made of a thermoplastic with V0 behaviour according to UL Subject 94, indicating a high flame retardancy class. The terminals are designed for connection with solid and stranded conductors. The connection terminals feature a self-release stripping length of 10 mm to ensure secure and quick connections.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Distribution board |
| Measuring range | AC 0,175 - 1 A |
| Output contacts | 1 C/O contact |
| Width | 17,5 mm |
| Type | IK 8839 |
| Variant | |
| Auxiliary voltage | AC 220 - 240 V |
| Contact equipping | 1 changeover contact |
| Switching point | 175 mA max. 20 A |
Questions & answers
What is the delivery time of Dold 0054127 IK8839.11 175mA MAX.20A AC220-240V current monitor?
The article Dold 0054127 IK8839.11 175mA MAX.20A AC220-240V current monitor is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0054127 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0054127 IK8839.11 175mA MAX.20A AC220-240V current monitor always at the best possible price. We can give you a discount of 2% on Dold 0054127 IK8839.11 175mA MAX.20A AC220-240V current monitor if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0054127 IK8839.11 175mA MAX.20A AC220-240V current monitor we can offer you a price of 181,29 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.