Dold 0053476 BL5903.03/00000 AC110V emergency stop module
|
698,84 EUR |
|||||||||||
|
( 831,62 EUR incl. VAT ) ≈ £584.93 | ≈ $768.03 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001976 | ||||||||||
| Mfg Part No: | 0053476 | ||||||||||
| UPC/EAN: | 4030641534769 | ||||||||||
| Weight: | 0.32 kg | ||||||||||
| Type: | BL5903.03/00000 AC110V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053476:
Applications
The module is designed for industrial applications where the reliability and safety of control are critical. It is used to safely implement emergency stop functions in systems that are to be automatically restarted after a power outage, provided no emergency stop command was issued. The configuration for a 2-channel connection from one emergency stop button makes it suitable for redundant safety circuits, where signals from two independent channels are monitored.
Functions and Equipment in Detail
The device features cross-short detection, ensuring that a short circuit between inputs is detected to avoid false alarms or hazardous conditions. Additionally, wire break and open circuit detection is performed on all inputs to detect open or broken wires. These functions increase the reliability of the safety control. The LED indicators for channel 1 and channel 2, as well as for fault diagnostics, enable visual monitoring of the operating status and support troubleshooting.
Technology Explained Simply
The module operates with a rated voltage of AC 110 V and is designed for use in industrial networks. The output contacts consist of up to 3 normally closed contacts (NO contacts), which can be used to control loads or additional safety components. The connection technology uses removable screw terminals, enabling flexible and secure connections. The maximum thermal current rating (Ith) is 5 A, defining the contact load capacity. The width of 90 mm conforms to standard enclosure dimensions, allowing compact mounting.
Compatibility and Accessories
The module is designed for use in safety control systems complying with standards EN ISO 13849-1 (Category 4, Performance Level e) and IEC/EN 62061 (SIL CL 3, SIL 3). It is therefore suitable for applications requiring high safety integrity. The feedback loop enables external contact amplification, facilitating integration into existing systems. The connection terminals are designed for wires with cross-sections of 2 x 1.5 mm² (with ferrule and plastic sleeve DIN 46228-1/-2/-3/-4) or 2 x 2.5 mm² (with ferrule DIN 46228-1/-2/-3).
Mounting and Installation
Mounting is carried out in standard enclosures, with the width of 90 mm allowing placement in typical enclosures. The removable terminals simplify installation and maintenance. The connection terminals are designed to ensure a secure and durable connection, even under mechanical stress. The device indicators support commissioning and maintenance by visually signaling the operating status.
Advantages in Operation
The integrated power failure detection ensures that the module monitors the supply status and only permits restart upon power restoration if no emergency stop command has been stored. Fault signaling via blink codes supports the diagnosis of malfunctions. The TÜV and UKCA certifications confirm compliance with European safety standards. The combination of safety functions, diagnostic capabilities, and compact design makes the module a reliable solution for critical applications.
| Technical data | |
| 1- / 2-channel | 1, 2 |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 3 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 90 mm |
| Type | BL 5903 |
| Cross fault detection | |
| Variant | |
| Contact equipping | 3 NO contacts |
| Nominal voltage | AC 110 V |
| Approvals and Markings | TÜV, UKCA |
| Variant | Für 2-kanaligen Anschluß von einem Not-Aus-Taster |
Questions & answers
What is the delivery time of Dold 0053476 BL5903.03/00000 AC110V emergency stop module?
The article Dold 0053476 BL5903.03/00000 AC110V emergency stop module is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053476 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053476 BL5903.03/00000 AC110V emergency stop module always at the best possible price. We can give you a discount of 2% on Dold 0053476 BL5903.03/00000 AC110V emergency stop module if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0053476 BL5903.03/00000 AC110V emergency stop module we can offer you a price of 667,39 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.