Dold 0053403 BH9250.02/001 UH=DC24V 2xAC 25A semiconductor contactor AC24-480V
|
347,92 EUR |
|||||||||||
|
( 414,02 EUR incl. VAT ) ≈ £291.21 | ≈ $382.36 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001541 | ||||||||||
| Mfg Part No: | 0053403 | ||||||||||
| UPC/EAN: | 4030641534035 | ||||||||||
| Weight: | 1.122 kg | ||||||||||
| Type: | BH9250.02/001 UH=DC24V 2xAC 25A | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053403:
Applications
This semiconductor contactor is designed for use in industrial and technical installations where reliable, disturbance-free, and low-maintenance switching functions are required. It is particularly suitable for applications where mechanical relays are unsuitable due to noise or mechanical wear. The zero-voltage switching ensures gentle load activation, which can extend the service life of connected devices. The devices are designed for use in environments with increased electrical stress, with protection circuitry using varistors to safeguard against overvoltage.
Functions and Equipment in Detail
The device features a control input X1, which operates with low current consumption and is therefore suitable for control via programmable logic controllers (PLCs). Control is digital via DC voltage. An integrated alarm output enables monitoring of operating conditions, particularly the temperature of the power semiconductors. In case of overtemperature, the alarm output is activated, allowing for early response to critical operating conditions. The temperature monitoring is designed as a protective function for the semiconductor components and can be reset by briefly interrupting the supply voltage at A1/A2.
Technology Explained Simply
Switching is performed via semiconductors, meaning there are no mechanical contacts that could wear out. Switching operations occur in the zero-voltage range, i.e., when the alternating voltage reaches zero, minimizing the generation of sparks and electrical disturbances. The integrated temperature monitoring monitors the heat development of the semiconductors and protects the device against thermal overload. The protection circuitry with varistors safeguards against voltage spikes caused by network disturbances or load switching operations.
Compatibility and Accessories
The device is designed for mounting on a DIN rail, enabling easy integration into existing enclosures. It is available in various configurations, including 1-pole, 2-pole, and 3-pole variants, with widths of 45 mm, 67.5 mm, or 112.5 mm. The BH 9250 series also allows up to three separate semiconductor contactors to be integrated into a single device, facilitating modular enclosure equipment. The UL-listed C/US certification confirms suitability for use in the USA and Canada.
Mounting and Installation
Mounting is done by snapping onto a DIN rail, with connections for supply voltage (A1/A2), control input (X1), load outputs (T1/T2), and alarm output (18) clearly labeled. Terminal designations are detailed in the datasheet. Installation requires no special tools, as the terminals are designed for standard connection cross-sections. The connection terminals are designed for secure wire connections, with a maximum short-circuit current rating of 600 A for the 2-pole version.
Advantages in Operation
Operation of the semiconductor contactor is noiseless and allows for high switching frequency without mechanical wear. The integrated temperature monitoring and alarm output enhance operational safety by enabling early detection of critical conditions. The low current consumption at control input X1 reduces the load on control systems. Compliance with IEC/EN 60947-4-2 and -4-3, as well as UL certification, guarantees adherence to international safety and quality standards. The devices are designed for use in industrial environments where reliability and longevity are critical.
| Technical data | |
| Approvals | UL |
| Load current up to | 50 A |
| Load voltage up to | AC 480 V |
| Number of poles | 1-pole, 2-pole, 3-pole |
| On/Off Input Control | DC |
| Width | 45 mm, 67,5 mm, 112,5 mm |
| Type | BH 9250 |
| Signalling output | |
| Temperature monitoring | |
| Variant | |
| Auxiliary voltage | DC 24 V |
| Contact equipping | with signal contact |
| Load current | 2 x AC 25 A |
| Load voltage | AC 24 - 480 V |
| Semiconductor output | 2-pole |
| Approvals and Markings | UL-listed C/US |
| Variant | Switching at zero crossing. Control input X1 with low current consumption. Monitoring output for the temperature protection |
Questions & answers
What is the delivery time of Dold 0053403 BH9250.02/001 UH=DC24V 2xAC 25A semiconductor contactor AC24-480V?
The article Dold 0053403 BH9250.02/001 UH=DC24V 2xAC 25A semiconductor contactor AC24-480V is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053403 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053403 BH9250.02/001 UH=DC24V 2xAC 25A semiconductor contactor AC24-480V always at the best possible price. We can give you a discount of 2% on Dold 0053403 BH9250.02/001 UH=DC24V 2xAC 25A semiconductor contactor AC24-480V if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053403 BH9250.02/001 UH=DC24V 2xAC 25A semiconductor contactor AC24-480V we can offer you a price of 332,26 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.