Dold 0052862 IP9109.27/107 AC230V 50/60Hz 0.7UN undervoltage relay
|
470,41 EUR |
|||||||||||
|
( 559,79 EUR incl. VAT ) ≈ £393.73 | ≈ $516.98 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002328 | ||||||||||
| Mfg Part No: | 0052862 | ||||||||||
| UPC/EAN: | 4030641528621 | ||||||||||
| Weight: | 0.234 kg | ||||||||||
| Type: | IP9109.27/107 AC230V 50/60HZ 0,7UN | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0052862:
Applications
This relay is suitable for monitoring single-phase networks, particularly in installations requiring high availability. It complies with standards IEC/EN 60255-1 and DIN VDE 0100-710, allowing its use in medical rooms as well. Early detection of voltage dips enables preventive maintenance and prevents costly damage.
Functions and Equipment in Detail
The device features a test button that allows simulation of under-voltage to check its functionality. The output contacts consist of one normally closed (NC) and one normally open (NO) contact, with the NC contact equipped with a self-latching function. This function ensures that the contact remains in the fault position after relay activation, even after voltage is restored, until the voltage at terminal 21 is switched off. An LED indicator signals the operating status: the LED lights up when the network is fault-free.
Technology Explained Simply
The relay operates on the principle of residual current, where the output relay is not activated in the event of a fault, but only when under-voltage occurs. The pickup delay ensures that short-term voltage dips do not trigger the relay. The hysteresis is approximately 2%, ensuring stable switching behavior. The contact configuration allows control of auxiliary relays or contactors, with a thermal current rating of 4 A for the contacts. The switching capacity is 3 A / AC 230 V for the NO contact and 1 A / AC 230 V for the NC contact, according to AC 15.
Compatibility and Accessories
The relay is designed for use in single-phase networks and can be combined with other devices from the VARIMETER series. The connection terminals are rated for conductor cross-sections of 2 x 2.5 mm² solid or 2 x 1.5 mm² stranded wire with ferrules. The electrical life expectancy is 500,000 switching cycles at 1 A and AC 230 V, while the mechanical life expectancy is 30 million switching cycles. Short-circuit resistance is ensured by a maximum fuse rating of 4 A gG / gL.
Mounting and Installation
The device is intended for installation in installation distributors. Mounting is done on a standard 35 mm DIN rail. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +70 °C. The operating altitude is limited to a maximum of 2000 m above sea level. The enclosure protection rating is IP 40, and the terminal protection rating is IP 40.
Operational Advantages
The self-latching function keeps the contact in the fault position after activation, enabling clear fault diagnosis. The LED indicator provides visual feedback on the operating status. Compliance with standards IEC/EN 60255-1 and DIN VDE 0100-710 ensures suitability for critical applications. Simple installation without auxiliary voltage reduces wiring and maintenance effort.
| Technical data | |
| 1- / 3-phase | 1 |
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Nominal voltage max. | AC 230 V |
| Output contacts | 1 NC contact, 1 NO contact |
| Width | 70 mm |
| Type | IP 9109.27/107 |
| Operate delay | |
| Variant | |
| Contact equipping | 1 NC contact, 1 NO contact with self-holding function |
| Nominal voltage | AC 230 V |
| Response value | 0,7 Un |
| Variant | For 1-phase mains. Fixed response value. With test button for simulation of undervoltage |
Questions & answers
What is the delivery time of Dold 0052862 IP9109.27/107 AC230V 50/60Hz 0.7UN undervoltage relay?
The article Dold 0052862 IP9109.27/107 AC230V 50/60Hz 0.7UN undervoltage relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0052862 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0052862 IP9109.27/107 AC230V 50/60Hz 0.7UN undervoltage relay always at the best possible price. We can give you a discount of 2% on Dold 0052862 IP9109.27/107 AC230V 50/60Hz 0.7UN undervoltage relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0052862 IP9109.27/107 AC230V 50/60Hz 0.7UN undervoltage relay we can offer you a price of 449,24 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.