Dold 0031961 IK7816.81 AC220-240V 0.1-1S flashing relay
|
108,55 EUR |
|||||||||||
|
( 129,17 EUR incl. VAT ) ≈ £90.86 | ≈ $119.30 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1000841 | ||||||||||
| Mfg Part No: | 0031961 | ||||||||||
| UPC/EAN: | 4030641319618 | ||||||||||
| Weight: | 0.08 kg | ||||||||||
| Type: | IK7816.81 AC220-240V 0,1-1S | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0031961:
Applications
This blink relay is used in systems requiring periodic switching functions, such as in safety systems, warning systems, operational indicator lights, or for controlling pumps and fans. The Start with pulse function enables precise control: the relay only begins its timing function when a short input pulse occurs, which is useful when integrating into existing control logic. The pulse time is adjustable between 0.1 and 1 second, suitable for fast blinking frequencies. The maximum timing function extends up to 60 minutes, although this specified variant is limited to the 0.1–1 s range.
Functions and Equipment in Detail
The device features 1 changeover contact as the output contact, which switches with delay. The contact configuration allows control of loads with a rated operating voltage of AC 250 V. The contact materials consist of AgSnO₂, ensuring high switching durability and low wear. The electrical life is at least 500,000 switching operations at 3 A and AC 230 V, while the mechanical life exceeds 30 million switching operations. The repeatability is ≤ 1 %, ensuring high precision during repeated switching operations. An LED indicator signals the contact position — it lights up when the output relay contact (15–18) is closed.
Technology Explained Simply
The timing function is adjusted continuously via a relative scale. The adjustment takes effect immediately, even during the timing process. However, changing the time setting during operation may cause unintended activation of the output relay, which must be considered during commissioning. The rated voltage is AC 220–240 V, with a voltage range coverage of 0.8 to 1.1 times the rated voltage. The drop-out voltage is 15 % of the rated voltage. The rated frequency is 50/60 Hz, with a frequency range of ±5 %. The device is designed for continuous operation and can be used at operating temperatures from -20 °C to +60 °C.
Compatibility and Accessories
The blink relay is available in two housing variants: The IK 7816 variant has a depth of 58 mm and bottom-mounted terminals, suitable for installation and industrial distributors. The SK 7816 variant has a depth of 98 mm and top-mounted terminals, designed for enclosures with mounting plates and cable ducts. The switching function is rated for loads up to 10 A (make) and 5 A (break) at AC 230 V. The maximum incandescent lamp load is 1200 W. For short-circuit resistance, a maximum fuse rating of 10 A gG/gL is specified.
Mounting and Installation
Mounting is performed in standard distributors or enclosures according to the housing variant. The terminals are designed for connection with wires. The terminal designation is A1/A2 for the input supply and 15/16/18 for the changeover contact. The housing protection rating is IP 40, and the terminals are IP 40, providing protection against contact and solid foreign objects, but not against splashing water or dust. The operating altitude is limited to below 2000 m.
Advantages in Operation
The high repeatability and continuous adjustability of the pulse time allow precise and flexible adaptation to various applications. The LED indicator simplifies diagnosis and monitoring of the operating status. The robust construction with long service life and high switching durability ensures reliable operation in industrial environments. Compliance with the standard IEC/EN 61812-1 guarantees the reliability and safety of the device.
| Technical data | |
| Enclosure design | Distribution board |
| Output contacts | 1 C/O contact |
| Time function(s) | Flasher relay |
| Time range | 0,1 s - 60 min |
| Width | 17,5 mm |
| Type | IK 7816 |
| Variant | |
| Contact equipping | 1 changeover contact delayed |
| Nominal voltage | AC 220 - 240 V |
| Pulse time | 0,1 - 1 s |
| Variant | Start with impulse |
Questions & answers
What is the delivery time of Dold 0031961 IK7816.81 AC220-240V 0.1-1S flashing relay?
The article Dold 0031961 IK7816.81 AC220-240V 0.1-1S flashing relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0031961 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0031961 IK7816.81 AC220-240V 0.1-1S flashing relay always at the best possible price. We can give you a discount of 2% on Dold 0031961 IK7816.81 AC220-240V 0.1-1S flashing relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0031961 IK7816.81 AC220-240V 0.1-1S flashing relay we can offer you a price of 103,67 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.