Product information for Dold 0019841:
Applications
This relay is suitable for monitoring three-phase networks in industrial installations, particularly in environments with high harmonic content, such as those found in thyristor systems, automatic reactive power compensation systems, or emergency power supplies. It can also be used for monitoring networks with a neutral conductor, although the N connection is not required. In this case, the nominal voltage must be converted to the line-to-line voltage. One application is the automatic switching to battery-powered supply for emergency lighting when the network voltage drops by 30%, in accordance with VDE 0108.
Functions and Equipment in Detail
The device detects voltage asymmetry by measuring the difference between two voltages and does not respond to symmetrical voltage drops as long as they do not fall below the fixed threshold of 0.7 times the nominal voltage. The response delay is continuously adjustable in the range of 0.5 to 5 seconds. In the case of incorrect phase sequence, the relay trips immediately. Reverse voltage detection is also integrated; depending on network conditions, reverse voltage is recognized either as asymmetry (delayed) or as incorrect phase sequence (immediate). The contact configuration includes two changeover contacts, which can be used for controlling auxiliary functions or alarms.
Technology Explained Simply
The asymmetry relay measures voltage symmetry by arithmetically averaging the three phase voltages. If the deviation exceeds the set asymmetry threshold (5 to 20% of nominal voltage) or if undervoltage falls below 0.7 times the nominal voltage, the output relay is deactivated after the set delay time. The LED indicator lights up when the output relay is active and turns off in the event of a fault. The adjustable response delay allows adaptation to the specific requirements of the installation. Harmonic immunity is ensured by the measurement principle, preventing distortion of the response values in networks with high harmonic content.
Compatibility and Accessories
The device is designed for use in enclosures and complies with the standard IEC/EN 60255-1. It is designed for frequencies of 50/60 Hz, with a frequency range of ±5% or ±10% for up to 1.5 seconds. The width is 70 mm, enabling compact mounting in standard enclosures. It is designed for monitoring three-phase networks, with connections L1, L2, and L3 directly connected to the network to be monitored. The output contacts (15-16, 15-18, 25-26, 25-28) allow integration into existing control and protection systems.
Mounting and Installation
Mounting is carried out in an enclosure, taking into account the width of 70 mm. Connections L1, L2, and L3 are directly connected to the phase conductors of the network to be monitored. The output contacts are intended for connection to external control or alarm devices. The response delay is adjusted using a rotary control on the device. The LED indicator provides visual monitoring of the operating status.
Advantages in Operation
Early detection of voltage asymmetry, undervoltage, or incorrect phase sequence increases operational safety. Preventive maintenance is enabled, helping to avoid costly damage to connected equipment. The simple installation without auxiliary voltage and robustness against harmonics make the device particularly suitable for industrial applications. The clear status indication via the LED simplifies diagnosis during operation.
| Technical data | |
| 1- / 3-phase | 3 |
| Enclosure design | Switch cabinet |
| Measuring range max. | 3 AC 690 V |
| Output contacts | 2 C/O contacts |
| Standard measuring range | 3 AC 400 V |
| Width | 70 mm |
| Type | AK 9840 |
| Operate delay | |
| Variant | |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3AC 380 V 50/60 Hz |
Questions & answers
What is the delivery time of Dold 0019841 AK9840.82 3AC50/60Hz 380V asymmetry relay?
The article Dold 0019841 AK9840.82 3AC50/60Hz 380V asymmetry relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0019841 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0019841 AK9840.82 3AC50/60Hz 380V asymmetry relay always at the best possible price. We can give you a discount of 2% on Dold 0019841 AK9840.82 3AC50/60Hz 380V asymmetry relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0019841 AK9840.82 3AC50/60Hz 380V asymmetry relay we can offer you a price of 639,38 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.