DEHN 952405 DGMTNS275FM surge arrester Type 2 guard M 4-pole for TN-S
|
447,35 EUR 452,63 EUR |
|||||||||||
|
( 532,35 EUR incl. VAT ) ≈ £374.43 | ≈ $491.64 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline | |||||||||||
| In Stock: >100 pieces | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 566734 | ||||||||||
| Mfg Part No: | 952405 | ||||||||||
| UPC/EAN: | 4013364108462 | ||||||||||
| Weight: | 0.479 kg | ||||||||||
| Type: | DG M TNS 275 FM | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for DEHN 952405:
Applications
The surge arrester is intended for use in electrical installations in the low-voltage range, particularly in buildings with a TN-S network configuration. It protects sensitive consumer devices, such as electronic controls, heating systems, lighting systems, or IT infrastructure, from damage caused by overvoltages resulting from lightning strikes or network disturbances. The application typically takes place in a distribution box or near the main distribution, to secure the entire installation.
Functions and Equipment in Detail
The device operates on the principle of diverting overvoltages via a non-conductive state during normal operation and a conductive state during overvoltage. Surge arrester monitoring is performed using Thermo-Dynamic-Control technology, which continuously monitors the state of the arrester. In the event of damage or malfunction of the arrester, this is indicated by a visual or electrical signal, enabling timely maintenance or replacement. This monitoring increases device safety and prevents unintended failures or damage to downstream equipment.
Technology Explained Simply
The DEHNguard M TNS 275 FM is certified according to standard EN 61643-11, which applies to Type 2 surge arresters. Type 2 arresters are intended for use near the consumer installation and protect against overvoltages caused by indirect lightning effects or network disturbances. The designation TNS refers to the TN-S network configuration, in which the protective earth conductor (PE) and the neutral conductor (N) are separated in the distribution board. The device is designed for four poles, enabling complete protection for phase conductors and the neutral conductor in a TN-S installation. The modular design allows flexible adaptation to different installation configurations.
Compatibility and Accessories
For use with the DEHNguard M TNS 275 FM, accessory 943405 DG MD TNS 275 FM is available, a Type 2 surge arrester guard MD, also designed for TN-S networks. This accessory can be used to extend or supplement the protection function in more complex installations. The combination of both modules enables a detailed protection strategy, particularly in installations with multiple distribution boards or different loads.
Mounting and Installation
Installation takes place in a suitable distribution box or enclosure, with electrical connections to be made in accordance with VDE and EN standards. The modules are inserted into the base unit, ensuring correct pole assignment and maintaining minimum distances from other components. Installation should be carried out by a qualified electrician to ensure the safety and functionality of the system.
Advantages in Operation
The integrated surge arrester monitoring with Thermo-Dynamic-Control increases operational safety. The user receives clear feedback on the status of the arrester, helping to optimize maintenance intervals and avoid unexpected failures. The modular design enables flexible adaptation to different installation configurations, increasing the reusability and scalability of the system. Certification according to EN 61643-11 guarantees compliance with European safety and performance standards for Type 2 surge arresters.
| General | |
| Degree of protection | Type 2 |
| Norm | EN 61643-11 |
| Monitoring technology | Thermo-Dynamik-Control |
| Network configuration | TN-S |
| Number of poles | 4 |
| Use in lightning protection zone concept | interfaces 0B - 1 and higher |
| Arrester use at 16.7 Hz – traction power supply systems | |
| Test voltage AC (UC) | 275 V |
| Nominal AC voltage (UN) | 230 / 400 V |
| Nominal frequency AC (fN) | 16.7 Hz |
| Standards | |
| Certification | UL |
| UL Standard | UL 1449 5th edition |
| UL File Number | E319777 |
| Technical data | |
| Energy coordination with terminal equipment (≤ 10 m) | type 2 + type 3 |
| Nominal voltage (a.c.) (UN) | 230 / 400 V (50 / 60 Hz) |
| Max. continuous operating voltage (AC) (UC) | 275 V (50 / 60 Hz) |
| Nominal discharge current (8/20 µs) (In) | 20 kA |
| Max. discharge current (8/20 µs) (Imax) | 40 kA |
| Voltage protection level [L-PE]/[N-PE] (UP) | ≤ 1.5 / ≤ 1.5 kV |
| Voltage protection level [L-PE]/[N-PE] at 5 kA (UP) | ≤ 1 / ≤ 1 kV |
| Response time (tA) | ≤ 25 ns |
| Max. mains-side overcurrent protection | 125 A gG |
| Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR) | 50 kArms |
| Temporary overvoltage (UT) – characteristic | 335 V / 5 sec. – Festigkeit, 440 V / 120 min. – sicherer Ausfall |
| Operating temperature range (TU) | -40 °C ... +80 °C |
| Operating state / fault indication | green / red |
| Number of ports | 1 |
| Cross-sectional area (min.) | 1.5 mm2 solid / flexible |
| Cross-sectional area (max.) | 35 mm2 stranded / 25 mm2 flexible |
| For mounting on | 35 mm DIN rails acc. to EN 60715 |
| Enclosure material | thermoplastic, red, UL 94 V-0 |
| Place of installation | indoor installation |
| Degree of protection | IP 20 (integrated) |
| Capacity | 4 Standard DIN module, DIN 43880 |
| Approvals | DEKRA, VDE, UL |
| Type of remote signalling contact | changeover contact |
| Switching capacity (a.c.) | 250 V / 0.5 A |
| Switching capacity (d.c.) | 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
| Cross-sectional area for remote signalling terminals | max. 1.5 mm2 solid / flexible |
| Test values according to UL 1449 | |
| Rated Voltage (AC, 50/60 Hz) | 230 V |
| MCOV (AC, 50/60 Hz) [L-N]/[L-G]/[N-G] | 275 V |
| Voltage protection rating (VPR) | ≤ 700 V |
| Nominal discharge current (8/20µs) ( In) | 20 kA |
| Maximum ambient temperature | 85 °C |
| UL 1449 edition | 5th edition |
| Type (SPD classification) | Type 4 component assembly |
Questions & answers
What is the delivery time of DEHN 952405 DGMTNS275FM surge arrester Type 2 guard M 4-pole for TN-S?
The article DEHN 952405 DGMTNS275FM surge arrester Type 2 guard M 4-pole for TN-S is currently in stock
According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of DEHN 952405 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you DEHN 952405 DGMTNS275FM surge arrester Type 2 guard M 4-pole for TN-S always at the best possible price. We can give you a discount of 2% on DEHN 952405 DGMTNS275FM surge arrester Type 2 guard M 4-pole for TN-S if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of DEHN 952405 DGMTNS275FM surge arrester Type 2 guard M 4-pole for TN-S we can offer you a price of 383,60 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
DEHN 943405 DG MD TNS 275 FM surge protector Type 2 guard MD
Mehrpoliger Überspannungsableiter DEHNguard MD, Typ 2 nach EN 61643-11, bestehend aus Basisteil und gesteckten Schutzmodulen. Hohe Gerätesicherheit durch Ableiterüberwachung mit ... Lieske Part No.: 889526 Mfg Part No: 943405 Type: DG MD TNS 275 FM |
414,10 EUR 418,97 EUR
![]() ≈ £346.60 | ≈ $455.10
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
Fitting accessory for DEHN 952405 DGMTNS275FM surge arrester Type 2 guard M 4-pole for TN-S
|
DEHN 943405 DG MD TNS 275 FM surge protector Type 2 guard MD
Mehrpoliger Überspannungsableiter DEHNguard MD, Typ 2 nach EN 61643-11, bestehend aus Basisteil und gesteckten Schutzmodulen. Hohe Gerätesicherheit durch Ableiterüberwachung mit ... Lieske Part No.: 889526 Mfg Part No: 943405 Type: DG MD TNS 275 FM |
414,10 EUR 418,97 EUR
![]() ≈ £346.60 | ≈ $455.10
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|