ABB 3AXD50000039044 LV AC wall-mounted drive for water and wastewater, IEC: Pn 7.5 kW, 17.0 A, 400 V (ACQ580-01-018A-4+B056)
|
1.805,95 EUR 1.881,99 EUR |
|||||||||||
|
( 2.149,08 EUR incl. VAT ) ≈ £1,526.03 | ≈ $2,019.05 plus delivery charges: 83,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Lieske Part No.: | 129067 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | 3AXD50000039044 | ||||||||||
| UPC/EAN: | 6438177459842 | ||||||||||
| Weight: | 6.8 kg | ||||||||||
| Type: | ACQ580-01-018A-4+B | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for ABB 3AXD50000039044:
Die ACQ580 Frequenzumrichter für den Wasser-/Abwasserbereich ermöglichen energieeffiziente Prozesse und eine prob¬lemlose Motorregelung. Dieser robuste und kompakte Frequenzumrichter verfügt über integrierte Funktionen für Pumpen¬applikationen wie z. B. geberlose Durchflussberechnung, Mehrpumpenregelung, Füllstandsregelung, sanfte Rohrfüllung und Trockenlaufschutz sowie über schnelle Rampen und eine Funktion zur Pumpenradreinigung. Die Bedienungsfreund¬lichkeit wird durch das intuitive Bedienpanel für die Hand-Aus-Auto-Steuerung erhöht. Der eingebaute Energierechner zeigt an, wie viel Energie durch Verwendung des Frequenzumrichters eingespart wurde. Zahlreiche Feldbusprotokolle erleichtern die Konnektivität.
Der ACQ580 Frequenzumrichter findet optimalen Einsatz in Wasserwerken, Wasseraufbereitungsanlagen, Entsalzungsanlagen, Kläranlagen sowie in Bewässerungssystemen.
| General | |
| Mains voltage | 480 |
| Mains frequency | 50/60 Hz |
| Number of phases input | Other |
| Number of phases output | 3 |
| Max. output frequency | 598 |
| Max. output voltage | 480 |
| Nominal output current I2N | 17 |
| Max. output at quadratic load at rated output voltage | 7.5 |
| Max. output at linear load at rated output voltage | 7.5 |
| Relative symmetric net frequency tolerance | 5 |
| Relative symmetric net voltage tolerance | 10 |
| Number of analogue outputs | 2 |
| Number of analogue inputs | 2 |
| Number of digital outputs | 3 |
| Number of digital inputs | 6 |
| Number of HW-interfaces industrial Ethernet | 0 |
| Number of interfaces PROFINET | 0 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 1 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces USB | 1 |
| Number of HW-interfaces parallel | 2 |
| Number of HW-interfaces other | 2 |
| Type of converter | U converter |
| Degree of protection (IP) | IP55 |
| Degree of protection (NEMA) | 12 |
| Height | 503 |
| Width | 128 |
| Depth | 239 |
| Power consumption | 240 |
| With control unit | |
| Application in industrial area permitted | |
| Application in domestic- and commercial area permitted | |
| Supporting protocol for TCP/IP | |
| Supporting protocol for PROFIBUS | |
| Supporting protocol for CAN | |
| Supporting protocol for INTERBUS | |
| Supporting protocol for ASI | |
| Supporting protocol for KNX | |
| Supporting protocol for MODBUS | |
| Supporting protocol for Data-Highway | |
| Supporting protocol for DeviceNet | |
| Supporting protocol for SUCONET | |
| Supporting protocol for LON | |
| Supporting protocol for PROFINET IO | |
| Supporting protocol for PROFINET CBA | |
| Supporting protocol for SERCOS | |
| Supporting protocol for Foundation Fieldbus | |
| Supporting protocol for EtherNet/IP | |
| Supporting protocol for AS-Interface Safety at Work | |
| Supporting protocol for DeviceNet Safety | |
| Supporting protocol for INTERBUS-Safety | |
| Supporting protocol for PROFIsafe | |
| Supporting protocol for SafetyBUS p | |
| Supporting protocol for BACnet | |
| Supporting protocol for other bus systems | |
| With optical interface | |
| With PC connection | |
| Integrated breaking resistance | |
| 4-quadrant operation possible | |
Questions & answers
What is the delivery time of ABB 3AXD50000039044 LV AC wall-mounted drive for water and wastewater, IEC: Pn 7.5 kW, 17.0 A, 400 V (ACQ580-01-018A-4+B056)?
The article ABB 3AXD50000039044 LV AC wall-mounted drive for water and wastewater, IEC: Pn 7.5 kW, 17.0 A, 400 V (ACQ580-01-018A-4+B056) is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of ABB 3AXD50000039044 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you ABB 3AXD50000039044 LV AC wall-mounted drive for water and wastewater, IEC: Pn 7.5 kW, 17.0 A, 400 V (ACQ580-01-018A-4+B056) always at the best possible price. We can give you a discount of 2% on ABB 3AXD50000039044 LV AC wall-mounted drive for water and wastewater, IEC: Pn 7.5 kW, 17.0 A, 400 V (ACQ580-01-018A-4+B056) if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 2 pieces of ABB 3AXD50000039044 LV AC wall-mounted drive for water and wastewater, IEC: Pn 7.5 kW, 17.0 A, 400 V (ACQ580-01-018A-4+B056) we can offer you a price of 1.738,23 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.