ABB 2CDS251001R0537 S201-K32 fuse switch 32 A System compact 1-pole K-characteristic
|
49,59 EUR |
|||||||||||
|
( 59,01 EUR incl. VAT ) ≈ £41.51 | ≈ $54.50 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 5 workdaysinfo_outline | |||||||||||
| In Stock: 3 pieces | |||||||||||
| Lieske Part No.: | 206593 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | 2CDS251001R0537 | ||||||||||
| UPC/EAN: | 4016779496131 | ||||||||||
| Weight: | 0.124 kg | ||||||||||
| Type: | S201-K32 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for ABB 2CDS251001R0537:
Applications
The S201-K32 is intended for use in indoor electrical distributions, particularly in systems with Compact modular construction. It is designed for mounting in enclosures or distribution boxes, where it can be used as a single switch or in combination with other devices in row mounting. The protection rating IP20 protects against finger contact and solid foreign objects, but not against splashing water or dust, meaning it must be used exclusively indoors. The ambient temperature during operation is up to 55 °C, enabling use under normal indoor conditions.
Functions and Equipment in Detail
The switch features a patented connection terminal that enables simple and secure connection. The connection is made via a pressure plate that securely fixes the conductor. The connection opening for cables is positioned above the connection opening for the phase bar, simplifying wiring and improving visibility. The terminal is designed for conductor cross-sections up to 35 mm² single-core and up to 25 mm² multi-core. The terminal insulation corresponds to protection class IP20, enhancing safety during installation and maintenance. The mounting depth is 69 mm, and the width corresponds to one module unit, enabling compact mounting in standard distribution boxes.
Technology Explained Simply
The K-characteristic of the switch ensures that it does not immediately trip during short-term current surges, such as those occurring during motor start-up or other inductive loads. Instead, selective tripping is enabled, which only occurs during sustained overload or short circuit. Energy limitation class 3 means that the switch limits a certain amount of energy during a short circuit, reducing thermal stress in the network. Overvoltage category 3 and pollution degree 3 indicate use in indoor environments with moderate pollution risk. The rated switching capacity Icn is 6 kA at 230 V, describing the switch's ability to safely interrupt a short-circuit current.
Compatibility and Accessories
The S201-K32 is designed for use in the Compact system and can be combined with various accessories. These include row terminals such as CMS-101PS and CMS-102PS, which enable secure connections between multiple devices. Busbars such as PS3/9, PS3/6, or PS3/12 System Compact, as well as the three-phase set 710SPM 10 mm² 1056 mm long, are suitable for connecting multiple switches in a distribution board. The busbar PS3/60 with 60 modules offers a flexible solution for larger installations. These accessories enable structured and secure wiring in the distribution board.
Mounting and Installation
Mounting is carried out in a suitable distribution box or enclosure, taking into account the mounting depth of 69 mm. The switch is not intended for flush mounting and must be installed in a closed housing. The connection terminal allows direct connection to conductors, with maximum cross-sections (35 mm² single-core, 25 mm² multi-core) not to be exceeded. Wiring is done via the upper connection opening, while the phase bar is connected at the bottom. Mounting is done in row construction, with the width of one module unit enabling placement in standard distribution boxes.
Advantages in Operation
The S201-K32 provides reliable protection for electrical lines and cables. The patented connection terminal with pressure plate ensures a secure and easy connection, which can be quickly restored even after frequent maintenance or modifications. The K-characteristic ensures selective tripping, minimizing disruption in the network. Compliance with international standards such as IEC/EN 60898-1 and UL1077 enables worldwide use. The power loss is 3.6 W, limiting thermal stress during operation. High quality is ensured by triple testing before delivery, increasing the reliability of the device.
| General | |
| Release characteristic | K |
| Number of poles (total) | 1 |
| Number of protected poles | 1 |
| Rated current | 32 |
| Rated insulation voltage Ui | 440 |
| Rated impulse withstand voltage Uimp | 4 |
| Rated short-circuit breaking capacity Icn EN 60898 at 230 V | 6 |
| Voltage type | AC/DC |
| Frequency | 60 |
| Current limiting class | 3 |
| Over voltage category | 3 |
| Pollution degree | 3 |
| Width in number of modular spacings | 1 |
| Built-in depth | 69 |
| Degree of protection (IP) | IP20 |
| Ambient temperature during operating | 55 |
| Connectable conductor cross section multi-wired | 25 |
| Connectable conductor cross section solid-core | 35 |
| Power loss | 3.6 |
| Concurrently switching N-neutral | |
| Additional equipment possible | |
| Explosion-proof | |
| Flush-mounted installation | |
Questions & answers
What is the delivery time of ABB 2CDS251001R0537 S201-K32 fuse switch 32 A System compact 1-pole K-characteristic?
The article ABB 2CDS251001R0537 S201-K32 fuse switch 32 A System compact 1-pole K-characteristic is currently in stock
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of ABB 2CDS251001R0537 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you ABB 2CDS251001R0537 S201-K32 fuse switch 32 A System compact 1-pole K-characteristic always at the best possible price. We can give you a discount of 2% on ABB 2CDS251001R0537 S201-K32 fuse switch 32 A System compact 1-pole K-characteristic if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 pieces of ABB 2CDS251001R0537 S201-K32 fuse switch 32 A System compact 1-pole K-characteristic we can offer you a price of 46,99 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for ABB 2CDS251001R0537 S201-K32 fuse switch 32 A System compact 1-pole K-characteristic
|
ABB 2CDL231001R1006 busbar PS3/6 System Compact
The ABB phase bar module PS3/6 is an installation device for safe and economical cross-wiring of circuit breakers, residual current protective devices, and other modular devices in the Compact system.Lieske Part No.: 372856 Mfg Part No: 2CDL231001R1006 Type: PS3/6 |
8,43 EUR
![]() ≈ £7.06 | ≈ $9.26
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
ABB 2CDL230001R1060 busbar 3-phase for cutting to length 10 mm² 60 modules L1v L2 L3 L1... PS3/60
PS 3/60 BusbarLieske Part No.: 624420 Mfg Part No: 2CDL230001R1060 Type: PS3/60 |
66,71 EUR
![]() ≈ £55.84 | ≈ $73.31
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
ABB 2CDL231001R1009 busbar PS3/9 System Compact
Residual Current Circuit Breakers System pro M compactBusbars (Compact only used for the series per M), not shortened since closed design (10 mm ²) Type: 3 phase, 9 modules Type: PS3 / 9 ... Lieske Part No.: 632996 Mfg Part No: 2CDL231001R1009 Type: PS3/9 |
9,88 EUR
![]() ≈ £8.27 | ≈ $10.86
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
ABB 2CCA880102R0001 CMS-102PS terminal block
The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and ...Lieske Part No.: 875555 Mfg Part No: 2CCA880102R0001 Type: CMS-102PS |
62,62 EUR
![]() ≈ £52.41 | ≈ $68.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
|
|
ABB 2CCA880101R0001 CMS-101PS terminal block
The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and ...Lieske Part No.: 875562 Mfg Part No: 2CCA880101R0001 Type: CMS-101PS |
62,62 EUR
![]() ≈ £52.41 | ≈ $68.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
|
|
ABB 2CDL231001R1012 busbar PS3/12 with end cap System Compact L1 L2 L3
Residual Current Circuit Breakers System pro M compact busbars (compact only used for the series per M), not shortened because Enclosed ( mm ²) Type: 3-phase, Type 2 modules: PS3 / 2 ... Lieske Part No.: 913797 Mfg Part No: 2CDL231001R1012 Type: PS3/12 |
13,43 EUR
![]() ≈ £11.24 | ≈ $14.76
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Ftg Goehringer 710SPM three-phase set 10 mm² 1056 mm long for COMPACT-system
Lieske Part No.: 2077717 Mfg Part No: 710SPM Type: S00 0710SPM |
57,80 EUR
![]() ≈ £48.38 | ≈ $63.52
Made to order · Delivery time approx. 20 workdaysinfo_outline
|