Zander Aachen Safety Module MINOS SL2D screw terminal; PL d/SILCL 2

Your rating:
Average rating
Rating for Zander Aachen Safety Module MINOS SL2D screw terminal; PL d/SILCL 2
( 4 / 5 ) 1 ratings
on request
( on request plus delivery charges
2025-12-13Delivery time on requestinfo_outline
Lieske Part No.:1599710
Mfg Part No: Safety Module MINOS SL2D
Weight:50 kg

Product information for Zander Aachen Safety Module MINOS SL2D:

Ultra-Compact Safety Relays – Modular, Space-Saving, and Cost-Efficient

The ultra-compact MINOS series safety relays offer a modern safety solution characterized by their compact design, high functionality, and flexible use. With a width of only 6 mm, these relays allow for space-saving installation in control cabinets without compromising on safety. The main goal of these relays is to provide a modular, cost-efficient safety solution that focuses on the essentials while still meeting the highest safety standards.

### Two Versions for Different Requirements
  • MINOS SL Series: With wear-free, safe semiconductor outputs. This technology ensures a particularly long service life and is ideal for applications with frequent switching operations.
  • MINOS SD Series: With safe relay outputs that provide potential-free switching contacts. This version is ideal for applications where galvanic isolation of signals is required.

Both series offer the highest level of safety up to PL e / Cat. 4 / SIL 3, making them the ideal solution for safety-critical applications in industry.

### Excellent Diagnostic Functions
The MINOS series relays are equipped with status and error LEDs that indicate the operating status and potential faults. This simplifies maintenance, reduces downtime, and allows for fast error detection and correction.

### Space-Saving Design – Only 6 mm Wide
With a width of only 6 mm, the MINOS safety relays are among the slimmest solutions on the market. This space-saving design enables a particularly high packing density in control cabinets, saves valuable space, and reduces installation costs. This is especially useful for machines and systems where space in the control cabinet is limited.

### Versatile Applications
The MINOS series safety relays are highly versatile and suitable for a wide range of safety-critical applications, including:
  • Monitoring Emergency Stop Buttons: Ensures the safe and immediate shutdown of the machine in hazardous situations.
  • Monitoring Safety Doors: Prevents the machine from operating when the safety door is open.
  • Monitoring Light Curtains: Detects entry into hazardous areas and safely shuts down the machine.
  • Reinforcement of Safe Outputs: Amplifies safe PLC outputs to control downstream contactors or relays.

### Certified for Demanding Areas of Use
The MINOS series safety relays are certified for continuous operation in combustion systems according to EN 50156-1 and EN 746-2. They also meet the requirements of IEC 61511-1, making them suitable for use in the process industry. These certifications ensure that the relays meet the stringent requirements for safety-critical applications in the process industry as well as in machinery, systems, and combustion systems.

### Technical Data
  • Width: 6 mm (ultra-compact)
  • Series:
  • - MINOS SL (semiconductor outputs, wear-free)
    - MINOS SD (relay outputs)
  • Safety Level: Up to PL e / Cat. 4 / SIL 3
  • Diagnostics: Status and error LEDs for easy fault detection
  • Certifications:
  • - EN 50156-1 and EN 746-2 (continuous operation in combustion systems)
    - IEC 61511-1 (use in the process industry)
  • Applications:
  • - Monitoring emergency stop buttons
    - Monitoring safety doors
    - Monitoring light curtains
    - Reinforcement of safe outputs (e.g., safe PLC outputs)
  • Areas of Use: Mechanical engineering, plant engineering, process industry, combustion systems



Please note...
This article has over-weight and though needs to be transported by a forwarding agency. Please mind, that the calculation of the delivery charges in the shopping cart disregard this aspect. Though, there will be corresponding surcharges after you send us your order.

Questions & answers

What is the delivery time of Zander Aachen Safety Module MINOS SL2D screw terminal; PL d/SILCL 2?

The article Zander Aachen Safety Module MINOS SL2D screw terminal; PL d/SILCL 2 is currently not in stock und muss auftragsbezogen bestellt werden.

According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Zander Aachen Safety Module MINOS SL2D to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Zander Aachen Safety Module MINOS SL2D screw terminal; PL d/SILCL 2 always at the best possible price. We can give you a discount of 2% on Zander Aachen Safety Module MINOS SL2D screw terminal; PL d/SILCL 2 if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Zander Aachen screw terminal PL d/SILCL 2 - Safety Module MINOS SL2D
Zander Aachen Safety Module MINOS SL2D screw terminal; PL d/SILCL 2
on request Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Zander Aachen screw terminal PL d/SILCL 2 - Safety Module MINOS SL2D
Name
Homepage
Street
ZIP-Code City
Telephone
Desired quantity
Comment
Data protection: The data entered here in the fields will be processed and stored electronically, according to GDPR Art. 6 par. 1b. It will only be used to answer your inquiry. Please look at our data protection policy for more infomation.
Name and email-address are the only required fields.