VDE-Kabel G397096 NHXH-J E90 4x1.5 mm² orange halogen-free sheathed cable

Your rating:
Average rating
product review for VDE-Kabel G397096 NHXH-J E90 4x1.5 mm² orange halogen-free sheathed cable
( 4.6 / 5 ) 38 ratings
VDE-Kabel G397096
This image may differ from the desired article.
-25% 2,75 EUR 3,69 EUR
incl. 0,70 EUR copper surcharge
( 3,27 EUR incl. VAT )
≈ £2.30  |  ≈ $3.02
plus delivery charges: 55,00 €
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
In Stock: >100 meters
1x VDE-Kabel G397096 NHXH-J E90 4x1.5 mm² orange halogen-free sheathed cable
Lieske Part No.:940139
Mfg Part No: G397096
Weight:0.228 kg
Type:NHXH 4X1,5 E90

Product information for VDE-Kabel G397096:

The NHXH 4X1.5 E90 cable from VDE-Kabel is a halogen-free power cable specifically developed for applications with high safety requirements in case of fire. It serves as a sheathed cable for indoor use, for example in buildings with fire alarm systems, emergency lighting, or backup power supply systems according to VDE 108. The cable is suitable for connecting devices of protection class II and features a test for functional integrity according to DIN 4102 part 12 (E30), meaning it maintains its electrical function for up to 90 minutes during a fire. This property makes it particularly suitable for critical infrastructures such as emergency lighting or alarm systems.

Applications
This cable is intended for installation indoors, particularly in air, concrete, or in conduits, provided no water accumulation occurs in the conduit. Direct installation in soil or water is not permitted. It is designed for standard cable support systems such as cable trays, cable ladders, or ceiling installations. The installation must ensure that the cable is protected against external mechanical influences and damage. Applications include areas where human and asset safety is paramount, for example in hospitals, administrative buildings, or public facilities.

Functions and Equipment in Detail
The cable consists of bare copper conductors, either single-strand or multi-strand. The conductor insulation is made of a cross-linked, halogen-free, ceramifiable storage insulation (HXI2), which ensures stable insulation at high temperatures. Conductor identification follows VDE 0293-308, enabling clear identification of individual conductors. A common conductor sheath protects the individual conductors, and the outer sheath is made of a halogen-free polymer mixture in orange, providing both identification and protection for the cable.

Technology Explained Simply
The halogen-free composition of the cable ensures that no toxic or corrosive gases are released in case of fire. Smoke development is minimal, improving visibility during a fire and facilitating evacuation. Flame retardancy is tested according to EN 50266-2-4 and IEC 60332-3 Cat.C, guaranteeing high resistance to flames and limited flame spread. The insulation integrity test FE 180 according to VDE 0472 T. 814 confirms that the insulation maintains its function even at high temperatures. The functional integrity test E 90 according to DIN 4102-12 ensures that the cable remains electrically functional even after 90 minutes of fire exposure. During design, it must be considered that the conductor resistance at 800 °C is approximately four times higher than at 20 °C, which must be taken into account during dimensioning.

Compatibility and Accessories
The cable is designed for use in systems with functional integrity and can be used in combination with other cables and support systems that also meet the E90 requirements. It is suitable for connecting devices of protection class II, which do not require grounding. Installation is carried out in standard support systems, where mechanical protection must be ensured by routing in conduits or in concrete.

Installation and Mounting
Installation is carried out indoors, with ambient temperature during installation ranging from +5 °C to +70 °C. After installation, ambient temperature can range from -30 °C to +70 °C. The bending radius is 15 times the cable diameter for single-conductor cables and 12 times for multi-conductor cables. Installation requires compliance with mechanical protection requirements, especially when routing in conduits, where water accumulation must be avoided.

Operational Advantages
This cable type offers high safety in case of fire due to its halogen-free composition, minimal smoke development, and the ability to maintain electrical function for 90 minutes. Its use in critical systems such as emergency lighting or fire alarm systems ensures reliable power supply even under extreme conditions. The orange color of the outer sheath facilitates identification in cable plans and during operation.

Functional Integrity E90
The test according to DIN 4102-12 (E30) confirms that the cable maintains its electrical function even after 90 minutes of fire exposure. This is crucial for the reliability of safety systems that must be activated in emergencies. The test is performed for all standard support systems, including cable trays, cable ladders, and ceiling installations.

Temperature Range
During installation, ambient temperature must be between +5 °C and +70 °C. After installation, ambient temperature can range from -30 °C to +70 °C, enabling broad applicability in various climatic conditions.

Bending Radius
The bending radius is 15 times the cable diameter for single-conductor cables and 12 times for multi-conductor cables, allowing flexible installation in confined spaces without compromising the mechanical integrity of the cable.

Tests
Flame retardancy is tested according to EN 50266-2-4 and IEC 60332-3 Cat.C, insulation integrity according to VDE 0472 T. 814 (FE 180), and functional integrity according to DIN 4102-12 (E90). These tests guarantee the cable’s reliability in critical applications.

Properties
The cable is halogen-free, flame-retardant, has minimal smoke development, and does not release corrosive gases, enhancing safety in case of fire.

Rated Voltage and Test Voltage
The rated voltage is 300/500 V, and the test voltage is 2000 V, defining the cable’s electrical load capacity under normal and test conditions.

Conductor Identification
Conductor identification follows VDE 0293-308, enabling clear identification of individual conductors and preventing errors during installation or commissioning.

Outer Sheath
The outer sheath is made of a halogen-free polymer mixture in orange, providing both mechanical protection and visual identification.

Copper Conductors
The conductors are made of bare copper, either single- or multi-strand, ensuring high electrical conductivity and mechanical stability.

Insulation
The conductor insulation is made of a cross-linked, halogen-free, ceramifiable storage insulation (HXI2), which ensures stable insulation at high temperatures and supports functional integrity.

Common Conductor Sheath
The common conductor sheath protects individual conductors from external influences and ensures a structured arrangement of conductors within the cable.

Functional Integrity E90
The test according to DIN 4102-12 (E30) confirms that the cable maintains its electrical function even after 90 minutes of fire exposure. This is crucial for the reliability of safety systems that must be activated in emergencies. The test is performed for all standard support systems, including cable trays, cable ladders, and ceiling installations.

Temperature Range
During installation, ambient temperature must be between +5 °C and +70 °C. After installation, ambient temperature can range from -30 °C to +70 °C, enabling broad applicability in various climatic conditions.

Bending Radius
The bending radius is 15 times the cable diameter for single-conductor cables and 12 times for multi-conductor cables, allowing flexible installation in confined spaces without compromising the mechanical integrity of the cable.

Tests
Flame retardancy is tested according to EN 50266-2-4 and IEC 60332-3 Cat.C, insulation integrity according to VDE 0472 T. 814 (FE 180), and functional integrity according to DIN 4102-12 (E90). These tests guarantee the cable’s reliability in critical applications.

Properties
The cable is halogen-free, flame-retardant, has minimal smoke development, and does not release corrosive gases, enhancing safety in case of fire.

Rated Voltage and Test Voltage
The rated voltage is 300/500 V, and the test voltage is 2000 V, defining the cable’s electrical load capacity under normal and test conditions.

Conductor Identification
Conductor identification follows VDE 0293-308, enabling clear identification of individual conductors and preventing errors during installation or commissioning.

Outer Sheath
The outer sheath is made of a halogen-free polymer mixture in orange, providing both mechanical protection and visual identification.

Copper Conductors
The conductors are made of bare copper, either single- or multi-strand, ensuring high electrical conductivity and mechanical stability.

Insulation
The conductor insulation is made of a cross-linked, halogen-free, ceramifiable storage insulation (HXI2), which ensures stable insulation at high temperatures and supports functional integrity.

Common Conductor Sheath
The common conductor sheath protects individual conductors from external influences and ensures a structured arrangement of conductors within the cable.

General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 °C
Temperature range after installation-30 °C
Bend radius single-core15 x cable diameter
Bending radius multi-core12 x cable diameter
Flame retardancyEN 50266-2-4, IEC 60332-3 Cat.C
Insulation integrityFE 180 according to VDE 0472 T. 814
Circuit integrityE 90 according to DIN 4102-12
Conductor markingVDE 0293-308
Outer sheathhalogen-free polymer blend orange
ConductorCopper conductor, bare, solid or stranded
Wire insulationnetworked halogen-free ceramisable insulation HXI2
Featureshalogen-free, flame-retardant, minimal smoke emission, no corrosive gases
Common core sheathingYes


Please note...
For this article, we charge 14,85 EUR for measuring, cutting and re-furling the cable. If you take a whole 100m or 500m cable reel, the charge will of course be dropped.

The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.

Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
This article contains a copper surcharge of 0,70 EUR. This depends on daily copper prices and weight of included copper. You can inquire the copper price via phone under +49 7666 884990

Questions & answers

What is the delivery time of VDE-Kabel G397096 NHXH-J E90 4x1.5 mm² orange halogen-free sheathed cable?

The article VDE-Kabel G397096 NHXH-J E90 4x1.5 mm² orange halogen-free sheathed cable is currently in stock

According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of VDE-Kabel G397096 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you VDE-Kabel G397096 NHXH-J E90 4x1.5 mm² orange halogen-free sheathed cable always at the best possible price. We can give you a discount of 2% on VDE-Kabel G397096 NHXH-J E90 4x1.5 mm² orange halogen-free sheathed cable if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x VDE-Kabel G397096 NHXH 4x1,5 E90 Cable orange halogen-free
VDE-Kabel G397096 NHXH-J E90 4x1.5 mm² orange halogen-free sheathed cable
2,75 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: VDE-Kabel G397096 NHXH 4x1,5 E90 Cable orange halogen-free
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
2 + 6 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.