Product information for VDE-Kabel 248117:
Applications
This cable is designed for use in industrial environments, for power supply to machines and systems, and for power distribution in power plants and local networks. It is particularly suitable for applications requiring high mechanical and electrical safety. Installation takes place in underground trenches, outdoors, or in enclosed cable ducts, with environmental conditions such as temperature and humidity being taken into account.
Functions and Equipment in Detail
The conductor is made of bare copper according to VDE 0295, where RM stands for round multi-strand. The cores are insulated with PVC and marked according to VDE 0293-308, enabling clear identification of individual cores. A filler layer ensures even distribution of the cores within the cable cross-section. The concentric conductor is constructed from bare copper wires, helically stranded around the common core sheathing, supplemented by a counter-helix made of copper tape. This construction ensures effective protection against electrical fields and contact voltage. The outer sheath is made of black PVC, which resists mechanical stress and environmental influences.
Technology Explained Simply
The rated voltage is 0.6/1 kV, indicating the maximum voltage for which the cable is designed. The test voltage of 4 kV serves quality assurance and ensures the cable remains stable even under increased voltage. The operating temperature is limited to a maximum of +70 °C, while the cable can be installed at temperatures ranging from -5 °C to +50 °C. After installation, it can be exposed to temperatures from -30 °C to +70 °C. The bending radius is 12 times the cable diameter, which must be considered during installation to avoid damage. Flame retardancy according to VDE 0472 T. 804, test method B (equivalent to IEC 332-1), ensures fire behavior characteristics and prevents flame propagation along the cable.
Compatibility and Accessories
The cable is designed for use in existing and new installations in industrial and power supply applications. It can be connected to standard cable connectors, switchgear, and distributors designed for a rated voltage of 0.6/1 kV.
Installation and Mounting
Installation must consider the specified bending radii and temperature limits. The cable is suitable for installation in underground trenches, outdoors, or in cable ducts. Outdoor installation requires special care regarding fixation and protective measures against mechanical damage. Indoor installation is carried out in cable ducts or open routing, where flame retardancy plays an important role.
Operational Advantages
The cable provides high protection against contact voltage due to the concentric conductor, increasing operational safety. The PVC insulation and black-colored outer sheath ensure high mechanical and chemical resistance. Flame retardancy according to VDE 0472 T. 804, test method B, reduces fire risk and prevents flame propagation. The use of bare copper as conductor material ensures high electrical conductivity and reliability throughout the cable’s service life.
Core Functions
The cable is designed as a fixed installation power and control cable for use in industrial and power engineering applications. The use of PVC as insulating and protective sheath material, along with the concentric conductor made of copper wires and tape, ensures high safety and reliability. The rated voltage of 0.6/1 kV and test voltage of 4 kV define the electrical limits of the cable. Temperature ranges and bending radius are critical for correct installation and safe operation. Flame retardancy according to VDE 0472 T. 804, test method B, is an important safety feature, especially in enclosed spaces and when installed in cable ducts.
Conclusion
The NYCWY 4X25 RM/16 from VDE-Kabel is a reliable and safety-oriented cable for use in industrial and power applications. It offers high protection against contact voltage and is suitable for a wide range of applications. The technical specifications and cable construction ensure high reliability and safety in operation.
Conclusion
The NYCWY 4X25 RM/16 from VDE-Kabel is a reliable and safety-oriented cable for use in industrial and power applications. It offers high protection against contact voltage and is suitable for a wide range of applications. The technical specifications and cable construction ensure high reliability and safety in operation.
| General | |
| Nominal voltage | 0,6/1 kV |
| Test voltage | 4 kV |
| Installation temperature range | -5 to +50 °C |
| Temperature range after installation | -30 to +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 12 x cable diameter |
| Flame retardancy | according to VDE 0472 T. 804, test type B (IEC 332-1) |
| Conductor | copper, bare, according to VDE 0295, RM (round stranded) |
| Wire insulation | PVC |
| Conductor marking | according to VDE 0293-308 |
| Concentric conductor | Made from bare copper wires, helically stranded with counter-twist from copper tape |
| Outer sheath | PVC, black |
The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.
Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
Questions & answers
What is the delivery time of VDE-Kabel 248117 NYCWY 4x25 mm² RM/16 mm² drum Eca PVC-insulated earth cable, concentric conductor?
The article VDE-Kabel 248117 NYCWY 4x25 mm² RM/16 mm² drum Eca PVC-insulated earth cable, concentric conductor is currently in stock
According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of VDE-Kabel 248117 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you VDE-Kabel 248117 NYCWY 4x25 mm² RM/16 mm² drum Eca PVC-insulated earth cable, concentric conductor always at the best possible price. We can give you a discount of 2% on VDE-Kabel 248117 NYCWY 4x25 mm² RM/16 mm² drum Eca PVC-insulated earth cable, concentric conductor if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.