Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

VDE-Kabel 246373 NYY-J 4x120 mm² SM Eca PVC-insulated earth cable drum

Your rating:
Average rating
product review for VDE-Kabel 246373 NYY-J 4x120 mm² SM Eca PVC-insulated earth cable drum
( 4.5 / 5 ) 270 ratings
VDE-Kabel 246373
This image may differ from the desired article.
67,55 EUR
incl. 60,73 EUR copper surcharge
( 80,38 EUR incl. VAT )
≈ £56.47  |  ≈ $74.85
plus delivery charges: 100,00 €
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
In Stock: >500 meters
1x VDE-Kabel 246373 NYY-J 4x120 mm² SM Eca PVC-insulated earth cable drum
Lieske Part No.:907158
Mfg Part No: 246373
UPC/EAN: 4018730150342
Weight:5.439 kg
Type:NYY-J 4X120 SM

Product information for VDE-Kabel 246373:

The cable NYY-J 4X120 SM from VDE-Kabel is a fixed-installed power and control cable designed for use outdoors, in the ground, indoors, and in cable ducts. It is used for the transmission of electrical power and control signals in industrial, commercial, and municipal installations. The designation NYY-J indicates a cable with PVC insulation and sheath, where the addition J stands for the integrated green-yellow protective conductor core. The type designation SM refers to a sector-shaped, multi-strand construction of the copper conductors, which ensures optimal current flow and mechanical stability, especially for larger cross-sections such as 120 mm².

Applications
This cable is suitable for a wide range of applications in the field of electrical power supply, particularly in building and industrial technology. It can be directly buried in the ground, making it especially suitable for outdoor installations, street lighting, garden and landscape lighting, and power supply to outdoor facilities. It can also be used indoors, for example in production halls or administrative buildings, in cable ducts or open installation. Outdoor use is possible due to the black-colored PVC sheath and robust construction, provided environmental conditions remain within the specified temperature limits.

Functions and Equipment in Detail
The conductor is made of bare copper, manufactured according to VDE 0295, and is constructed in a sector-shaped, multi-strand configuration (SM). This design ensures even current distribution and reduces mechanical stresses during installation. The cores are insulated with PVC, with core identification according to VDE 0293-308. For up to five cores, identification is done by color, with the green-yellow core designated as the protective conductor (J). The filler layer ensures stable cable shape, while the outer sheath made of black PVC enhances mechanical and chemical resistance.

Technology Explained Simply
The rated voltage is 0.6/1 kV, meaning the cable is designed for operating voltages up to 1 kV with a phase voltage of 0.6 kV. The test voltage of 4 kV serves quality assurance and ensures the cable remains stable even under increased electrical stress. The maximum operating temperature is +70 °C, with cable installation permitted at temperatures from -5 °C. After installation, the cable can be operated at temperatures from -30 °C to +70 °C. The bending radius is 15 times the cable diameter for single-core conductors and 12 times for multi-core cables, enabling flexible installation without damaging the conductors. Flame retardancy according to VDE 0472 Part 804, test method B (equivalent to IEC 332-1), ensures the cable does not propagate live flame during fire exposure, which is important for safety in buildings and installations.

Compatibility and Accessories
The cable is designed for use in electrical installations executed according to current standards for power and control cables. It is compatible with standard cable lugs, cable glands, and other connection elements designed for PVC insulation and copper conductors. The use of specialized tools for cable processing, such as cable cutters or wire strippers, is required to cleanly remove the insulation and connect the conductors. There are no specific accessory items directly associated with this cable type, as it is a standard cable for general applications.

Installation and Mounting
Installation is performed by fixed laying, which can be done in the ground, in cable ducts, or indoors. Underground installation requires sufficient depth and protective measures against mechanical damage, for example, using a protective sleeve or protective layer. Bending radii must be observed to avoid damaging the conductors. Cable ends are connected using appropriate connection elements, taking into account the electrical and mechanical requirements of the respective installation. Installation should be carried out considering environmental conditions and maximum operating temperature.

Advantages in Operation
The cable offers high mechanical strength and chemical resistance, making it suitable for use in various environments. The integrated green-yellow protective conductor (J) meets electrical safety requirements and enables proper earthing. The PVC insulation and outer sheath provide good insulation and protection against external influences. Flame retardancy increases safety in buildings and installations. The sector-shaped, multi-strand construction of the conductors (SM) ensures even current distribution and reduces heat generation under high loads.

General
Nominal voltage0,6/1 kV
Test voltage4 kV
Installation temperature range-5 °C
Temperature range after installation-30 °C
Operation temperature+70 °C
Bend radius single-core15 x cable diameter
Bending radius multi-core12 x cable diameter
Flame retardancyaccording to VDE 0472 Part 804, test type B
ConductorCopper, bare, sector-shaped stranded (SM)
Wire insulationPVC
Conductor markingaccording to VDE 0293-308
Outer sheathPVC black


Please note...
For this article, we charge 14,85 EUR for measuring, cutting and re-furling the cable. If you take a whole 100m or 500m cable reel, the charge will of course be dropped.

The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.

Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
This article contains a copper surcharge of 60,73 EUR. This depends on daily copper prices and weight of included copper. You can inquire the copper price via phone under +49 7666 884990

Questions & answers

What is the delivery time of VDE-Kabel 246373 NYY-J 4x120 mm² SM Eca PVC-insulated earth cable drum?

The article VDE-Kabel 246373 NYY-J 4x120 mm² SM Eca PVC-insulated earth cable drum is currently in stock

According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of VDE-Kabel 246373 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you VDE-Kabel 246373 NYY-J 4x120 mm² SM Eca PVC-insulated earth cable drum always at the best possible price. We can give you a discount of 2% on VDE-Kabel 246373 NYY-J 4x120 mm² SM Eca PVC-insulated earth cable drum if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x VDE-Kabel 246373 NYY-J 4x120 SM Earth Cable
VDE-Kabel 246373 NYY-J 4x120 mm² SM Eca PVC-insulated earth cable drum
67,55 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: VDE-Kabel 246373 NYY-J 4x120 SM Earth Cable
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
1 + 5 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.