Tekbox TBCDNE-M2-CAL2 OSL adapter for impedance measurement
and calibration TBCDNE-M2
|
310,91 EUR 310,91 EUR |
|
|
( 369,98 EUR incl. VAT ) ≈ £260.23 | ≈ $341.69 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |
| Lieske Part No.: | 1156842 |
|---|---|
| Mfg Part No: | TBCDNE-M2-CAL2 |
| Weight: | 0.2 kg |
Product information for Tekbox TBCDNE-M2-CAL2:
Applications
The OSL adapter is used in industrial and technical environments where precise calibration of measurement devices is required for analyzing high-frequency lines. It is particularly suitable for users in the fields of electrical engineering, network technology, and EMC testing who work with the TBCDNE-M2 system. Calibration is typically performed before actual measurements to minimize systematic errors and ensure reproducible results. Applications include laboratories, maintenance work on network infrastructures, or the development of electronic devices.
Functions and Equipment in Detail
The adapter is designed to provide the three fundamental calibration references – Open, Short, and Load – for common-mode impedance measurement. These references are necessary to tune the measurement system to known values, thereby ensuring the accuracy of subsequent measurements. The OSL adapters are physical components that are directly connected to the TBCDNE-M2 device. They are not intended for operation without the main device, but serve exclusively as calibration aids.
Technology Explained Simply
OSL stands for Open, Short, Load – the three fundamental calibration references in impedance measurement. In the Open reference, the measurement path is open; in the Short reference, it is shorted; and in the Load reference, a known load (e.g. 50 Ω) is connected. These references are used to calibrate the measurement system by detecting and correcting deviations between expected and measured values. Common-mode impedance refers to the impedance that occurs simultaneously in both conductors of a differential signal and is particularly important in analyzing disturbances in data lines. The adapter enables precise calibration of this specific type of impedance.
Compatibility and Accessories
The OSL adapter is specifically designed for calibrating the TBCDNE-M2 device from Tekbox. It is not universally applicable, but requires use with this specific device. Use is exclusively in conjunction with the TBCDNE-M2, and calibration must be performed according to the manufacturer’s instructions.
Mounting and Installation
Installation is done by directly connecting the OSL adapter to the corresponding measurement terminals of the TBCDNE-M2 device. No additional tools or mounting aids are required. Calibration is initiated via the device’s user interface, with the adapter placed in the respective position (Open, Short, Load). The exact procedure is described in the TBCDNE-M2 device manual.
Advantages in Operation
Using the OSL adapter ensures high measurement accuracy and reproducibility of results. Precise calibration of common-mode impedance enables the TBCDNE-M2 system to deliver reliable data, which is crucial for diagnosing network disturbances or developing electromagnetically compatible devices. Calibration is quick and requires no additional measurement equipment, making the workflow more efficient.
| General | |
| Compatibility | TBCDNE-M2 |
| Manufacturer | Tekbox |
Questions & answers
What is the delivery time of Tekbox TBCDNE-M2-CAL2 OSL adapter for impedance measurement and calibration TBCDNE-M2?
The article Tekbox TBCDNE-M2-CAL2 OSL adapter for impedance measurement and calibration TBCDNE-M2 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Tekbox TBCDNE-M2-CAL2 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Tekbox TBCDNE-M2-CAL2 OSL adapter for impedance measurement and calibration TBCDNE-M2 always at the best possible price. We can give you a discount of 2% on Tekbox TBCDNE-M2-CAL2 OSL adapter for impedance measurement and calibration TBCDNE-M2 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

