Distribution from Telegärtner
You have been filtering for Telegärtner and therefore you see now only Distribution from Telegärtner .
You can choose other manufacturers on the left side in the menu or get the complete overview.
Distribution from Telegärtner
|
Telegärtner 100000045 Führungsstift f.Rüttelsicherung
Anmerkungen: Stift Verkaufseinheit: 1 ST.Lieske Part No.: 493273 Mfg Part No: 100000045 |
1,07 EUR
![]() ≈ £0.92 | ≈ $1.23 plus delivery charges
Delivery time on requestinfo_outline
|
|
Telegärtner 100000046 Führungsbuchse f.Rüttelsicherung
Anmerkungen: Buchse Verkaufseinheit: 1 ST.Lieske Part No.: 493274 Mfg Part No: 100000046 |
1,60 EUR
![]() ≈ £1.38 | ≈ $1.85 plus delivery charges
Delivery time on requestinfo_outline
|
|
Telegärtner 100023254 Federleiste B39 gemäß DIN 41618
Anmerkungen: Lötanschluss, 39-poligBrandschutzklasse: Nicht relevant Brennendes Abtropfen: Nicht relevant Rauchentwicklung: Nicht relevant Säureentwicklung: Nicht relevant Maße in mm: a=83, b=74, ... Lieske Part No.: 493245 Mfg Part No: 100023254 |
22,18 EUR
![]() ≈ £19.16 | ≈ $25.60 plus delivery charges
Delivery time on requestinfo_outline
|
|
Telegärtner 100023255 Federleiste B30 gemäß DIN 41622
Anmerkungen: Lötanschluss, 30-poligBrandschutzklasse: Nicht relevant Brennendes Abtropfen: Nicht relevant Rauchentwicklung: Nicht relevant Säureentwicklung: Nicht relevant Maße in mm: a=83, b=74, ... Lieske Part No.: 493247 Mfg Part No: 100023255 |
94,15 EUR
![]() ≈ £81.35 | ≈ $108.65 plus delivery charges
Delivery time on requestinfo_outline
|
|
Telegärtner 100023261 Messerleiste A12 gemäß DIN 41622
Anmerkungen: Lötanschluss, 12-poligBrandschutzklasse: Nicht relevant Brennendes Abtropfen: Nicht relevant Rauchentwicklung: Nicht relevant Säureentwicklung: Nicht relevant Maße in mm: a=59, b=50, ... Lieske Part No.: 493248 Mfg Part No: 100023261 |
5,55 EUR
![]() ≈ £4.80 | ≈ $6.40 plus delivery charges
Delivery time on requestinfo_outline
|
|
Telegärtner 100023262 Messerleiste A16 gemäß DIN 41622
Anmerkungen: Lötanschluss, 16-poligBrandschutzklasse: Nicht relevant Brennendes Abtropfen: Nicht relevant Rauchentwicklung: Nicht relevant Säureentwicklung: Nicht relevant Maße in mm: a=71, b=62, ... Lieske Part No.: 493284 Mfg Part No: 100023262 |
5,80 EUR
![]() ≈ £5.01 | ≈ $6.69 plus delivery charges
Delivery time on requestinfo_outline
|
|
Telegärtner 100023263 Messerleiste A20 gemäß DIN 41622
Anmerkungen: Lötanschluss, 20-poligBrandschutzklasse: Nicht relevant Brennendes Abtropfen: Nicht relevant Rauchentwicklung: Nicht relevant Säureentwicklung: Nicht relevant Maße in mm: a=83, b=74, ... Lieske Part No.: 493286 Mfg Part No: 100023263 |
35,24 EUR
![]() ≈ £30.45 | ≈ $40.67 plus delivery charges
Delivery time on requestinfo_outline
|
|
Telegärtner 100023265 Messerleiste A26 gemäß DIN 41618
Anmerkungen: Lötanschluss, 26-poligBrandschutzklasse: Nicht relevant Brennendes Abtropfen: Nicht relevant Rauchentwicklung: Nicht relevant Säureentwicklung: Nicht relevant Maße in mm: a=83, b=74, ... Lieske Part No.: 493287 Mfg Part No: 100023265 |
9,23 EUR
![]() ≈ £7.97 | ≈ $10.65 plus delivery charges
Delivery time on requestinfo_outline
|
|
Telegärtner 100027372 Telegaertner B00005A0009Y cover, 2-151x80x8, 7 alpine white
Notes: not suitable for J00020A0512 / J00020A0513Fire protection class: Not relevant Burning droplets: Not relevant Smoke development: Not relevant Acid development: Not relevant Design: 2-way, ... Lieske Part No.: 314550 Mfg Part No: 100027372 |
19,50 EUR
![]() ≈ £16.85 | ≈ $22.50 plus delivery charges
Delivery time on requestinfo_outline
|
TK Distribution & Cabinet Technology – Technical Background & Applications
TK distribution and network cabinet technology forms the physical backbone of every structured cabling and telephone system. It protects active and passive components (switches, patch panels, PBX, UPS) and enables organised cable management. Wall cabinets (9–22U) are suitable for small offices and branch locations with compact space requirements; free-standing floor cabinets (22–47U) accommodate large server racks, PBX systems and redundant power supplies. 19-inch cabinet technology conforms to DIN IEC 60297 and EIA-310-D standards; nominal width 482.6 mm (19 inches), rack units (U) of 44.45 mm. For fibre optic main distribution frames (building internal distribution per ISO/IEC 11801), special fibre optic distribution units with splice modules, pigtails and LC/SC couplings are used. Cooling, cable entry plates (to EN 50085) and locking systems (swing handle, 3-point) increase safety and operational reliability of cabinet technology.
Patch panels for populating the cabinet: Patch Panels. Active network components (switches) are under Surge Protection & Network. Project planning and quotes for complete TK infrastructure: sales@industry-electronics.com.
Application Areas
| ✓ Business Telephony & Call Centres | ✓ Authorities & Public Institutions |
| ✓ Industrial Environments & Production Halls | ✓ Hotels & Hospitality |
| ✓ Hospitals & Care Facilities | ✓ Data Centres & IT Infrastructure |
Frequently Asked Questions
▶ How do I calculate the space requirement in rack units (U)? Count all components to be installed and their rack height: switches (1–2U), patch panels (1U per 24 ports), PBX (1–4U), UPS (2–4U), cable management (1U per 24 patch cables), free reserve (at least 20%). Example: 24-port switch (1U) + 24-port patch panel (1U) + cable management (1U) + reserve = 9U rack sufficient for a small node. |
▶ From what cabinet size is active cooling required? As a rule of thumb: from a heat load of 500 W in the cabinet, active cooling (air conditioning unit or cold aisle concept) should be planned. Passively cooled cabinets with roof fan and perforation suffice up to approx. 500–800 W. Modern PoE switches can consume up to 30 W (PoE+) or 60 W (PoE++) per port – this adds up to 720 W for PoE alone in fully populated 24-port switches. |
▶ What is the difference between a network cabinet and a server cabinet? Network cabinets are optimised for passive and active network components: often with glass front door, narrower depth (600–800 mm), extensive cable management. Server cabinets are deeper (800–1200 mm), often have solid steel doors (security) and are designed for higher load capacity and intensive cooling. For combined installations (server + network), universal 19-inch cabinets with 800–1000 mm depth are recommended. |
Why industry-electronics.de?
▶ Professional TK Range Over 15,000 telecoms products from Agfeo, Auerswald, Snom, Yealink, Innovaphone, Gigaset and other leading manufacturers. | ▶ B2B Expert Advice Our TK team advises on SIP migration, DECT planning, emergency call systems and standards compliance – free and vendor-neutral. | ▶ Volume Pricing from 1 Unit Quantity discounts, project prices and framework agreements for system integrators, authorities and industrial companies. |
▶ Fast Delivery Most items available from stock – free shipping across Germany from minimum order value. | ▶ 20+ Years TK Experience For over 20 years, Industry-Electronics has supplied system houses, authorities and industrial customers with professional telecoms technology. | ▶ Standards-Compliant Range All products comply with applicable EN, ETSI and VDE standards and regulatory approvals for commercial use. |




