Electrical Insulation from Moxa

You have been filtering for Moxa and therefore you see now only Electrical Insulation from Moxa .
You can choose other manufacturers on the left side in the menu or get the complete overview.


Electrical Insulation from Moxa

Moxa TCC-82 , optischer Isolator für RS232 Moxa LogoMoxa TCC-82 , optischer Isolator für RS232 4-channel 4 KV RMS Isolation for 1 minuteDual self-powered or selectable external power sourceSurge protection, 15 KV ESDAuto baudrate sensingCompact size
TCC-82 is a signal isolator that provides ...

Lieske Part No.: 851508
Mfg Part No: TCC-82
78,00 EUR
Moxa TCC-82 plus VAT
≈ £67.39  |  ≈ $90.48
Delivery time on requestinfo_outline

⚡ CPE – Central Potential Equalisation in Medical Locations

Mandatory per IEC 60364-7-710 / DIN VDE 0100-710: In Group 1 and Group 2 medical locations, a Central Protective Equipotential Bonding (CPE) system is mandatory. All conductive parts – enclosures, beds, infusion stands, pipework – are connected to a common bonding conductor (max. 0.1 Ωresistance) and protective earth. Purpose: fault currents cannot flow through the patient.
 
Group 1(X-ray, physiotherapy): leakage < 500 µA · Group 2(OR, ICU, cardiac cath lab): leakage < 10 µA · Inspection intervals: STKannually by qualified electrician, MTKevery 2 years by authorised inspector.

⚡ Application Areas for Electrical Isolation Components

OR & Intensive Care

Group-2 locations: IT networks with monitoring, 2-MOPP power supplies, CPE with < 10 µA leakage.

Imaging & Diagnostics

X-ray, CT, MRI: Group-1 requirements, leakage current limitation, insulation testing per IEC 60601.

GP Practice & Outpatient

Minor procedures, ECG, ultrasound: isolation between mains and patient monitoring systems.

Laboratory & IVD

Analysers, PCR systems: galvanic isolation prevents measurement interference from earth loops.

OEM Medical Device Mfg.

Isolation components as device sub-assembly: certification evidence per EU MDR and IEC 60601-1.

Related Categories

Medical Power Supplies

IEC-60601-1 PSUs (2 MOPP/1 MOPP) – complement isolation components in the complete system.

Insulation Testers

Test equipment for STK/MTK inspections: leakage current, insulation resistance, protective earth per IEC 62353.

Medical PC Components

IEC-60601-compatible industrial hardware for clinical systems and embedded medical devices.

Medical Technology – Overview

All product areas for medical use at a glance.

MOPP Reference

< 300 µA: MOOP (operator) · < 100 µA: 1 MOPP · < 10 µA: 2 MOPP (direct patient contact). PSUs and isolation must match the required protection level.