You have been filtering for DELOCK and therefore you see now only Electrical Insulation from DELOCK displayed.
You can choose other manufacturers on the left side in the menu or get the complete overview.


Electrical Insulation from DELOCK

DELOCK USB Isolator with 5 KV Isolation DELOCK LogoDELOCK USB Isolator with 5 KV Isolation The DELOCK USB isolator with manufacturer number 62588 serves as a galvanic separator between a host PC and a connected USB device. By providing electrical isolation, it prevents noise in audio ...

Lieske Part No.: 827417
Mfg Part No: 62588
79,08 EUR
DELOCK 62588 plus VAT
≈ £65.95  |  ≈ $88.33
Delivery time from supplier's stock (ca.) 10 workdaysinfo_outline

⚡ CPE – Central Potential Equalisation in Medical Locations

Mandatory per IEC 60364-7-710 / DIN VDE 0100-710: In Group 1 and Group 2 medical locations, a Central Protective Equipotential Bonding (CPE) system is mandatory. All conductive parts – enclosures, beds, infusion stands, pipework – are connected to a common bonding conductor (max. 0.1 Ωresistance) and protective earth. Purpose: fault currents cannot flow through the patient.
 
Group 1(X-ray, physiotherapy): leakage < 500 µA · Group 2(OR, ICU, cardiac cath lab): leakage < 10 µA · Inspection intervals: STKannually by qualified electrician, MTKevery 2 years by authorised inspector.

⚡ Application Areas for Electrical Isolation Components

OR & Intensive Care

Group-2 locations: IT networks with monitoring, 2-MOPP power supplies, CPE with < 10 µA leakage.

Imaging & Diagnostics

X-ray, CT, MRI: Group-1 requirements, leakage current limitation, insulation testing per IEC 60601.

GP Practice & Outpatient

Minor procedures, ECG, ultrasound: isolation between mains and patient monitoring systems.

Laboratory & IVD

Analysers, PCR systems: galvanic isolation prevents measurement interference from earth loops.

OEM Medical Device Mfg.

Isolation components as device sub-assembly: certification evidence per EU MDR and IEC 60601-1.

Related Categories

Medical Power Supplies

IEC-60601-1 PSUs (2 MOPP/1 MOPP) – complement isolation components in the complete system.

Insulation Testers

Test equipment for STK/MTK inspections: leakage current, insulation resistance, protective earth per IEC 62353.

Medical PC Components

IEC-60601-compatible industrial hardware for clinical systems and embedded medical devices.

Medical Technology – Overview

All product areas for medical use at a glance.

MOPP Reference

< 300 µA: MOOP (operator) · < 100 µA: 1 MOPP · < 10 µA: 2 MOPP (direct patient contact). PSUs and isolation must match the required protection level.

OEM & Project Orders

Framework agreements, component reservation, and certification documentation on request for device manufacturers.