Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
Schneider Electric Logo

Schneider Electric TM262L01MESE8T PLC control Modicon M262 IIoT-capable 5 ns/instruction

Your rating:
Average rating
product review for Schneider Electric TM262L01MESE8T PLC control Modicon M262 IIoT-capable 5 ns/instruction
( 0 / 5 ) 0 ratings
831,11 EUR
( 989,02 EUR incl. VAT )
≈ £696.47  |  ≈ $912.56
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 34 workdaysinfo_outline
1x Schneider Electric TM262L01MESE8T PLC control Modicon M262 IIoT-capable 5 ns/instruction
Datasheet:file_download Download
Lieske Part No.:1017460
Mfg Part No: TM262L01MESE8T
UPC/EAN: 3606482452442
Weight:0.822 kg


More spare projector bulbs for your Panasonic Beamer


Complementary
Supply voltage limits20.4…28.8 V DC
PLC Power Consumption82 W
Inrush current40 A
Overvoltage protectionWith
Discrete input number4, discrete input fast input conforming to IEC 61131-2 Type 1
Discrete input voltage24 V
Discrete input voltage typeDC
Discrete input logicSink
Voltage state 1 guaranteed>= 15 V for DC
Discrete input current7.5 mA for fast input
Input impedance2.81 kOhm for input
Configurable filtering time0.001 ms for fast input; 0.002 ms for fast input; 0.005 ms for fast input; 0.01 ms for fast input; 0.05 ms for fast input; 0.1 ms for fast input; 0.5 ms for fast input; 1 ms for fast input; 4 ms for fast input; 12 ms for fast input
Discrete output number4 transistor fast output
Discrete output voltage24 V DC
Discrete output current0.5 A for fast output (Q0...Q3)
Discrete output typeTransistor
Discrete output logicSource
Output voltage limits30 V DC
Maximum current per output common0.5 A with Q0...Q3 for fast output
Maximum output frequency300 kHz
Accuracy+/- 0.1 % at 0.02…0.1 kHz for fast output; +/- 1 % at 0.1…1 kHz for fast output
Maximum leakage current10 µA for output
Protection typeShort-circuit and overload protection with automatic reset; Reverse polarity protection; Short-circuit protection
Reset time200 ms automatic reset fast output
Maximum number of I/O expansion module7TM3 IO module (local I/O-Architecture); 7TM3 IO module (remote I/O-Architecture); 64TM3, TM5 or TM7 IO island (distributed I/O-Architecture)
Execution time for 1 KInstruction0.005 ms
Memory capacity32 MB for program RAM; 32 MB for OS/website RAM; 192 MB for system memory RAM
Data backed up1 GB built-in flash memory for backup of user programs
Backup time1000 h at 25 °C
Application structure8 event tasks; 4 cyclic master tasks; 3 cyclic master tasks + 1 freewheeling task; 8 external event tasks
Realtime clockWith
Cycle time0.5 ms
Positioning functionsLibraries axes coordinated function
Integrated connection typeEthernet 1 with RJ45 connector and 10/100BASE-T interface ; Ethernet 2 with 2 RJ45 connector and 100/1000BASE-T interface ; Serial link with RJ45 connector and RS232/RS485 interface ; Smart communication bus (TMSCO1 only); TM3 IO bus; USB type mini B
Transmission rate115 kbit/s for bus length of 15 m for RS485; 115 kbit/s for bus length of 3 m for RS232; 480 Mbit/s for bus length of 3 m for USB; 10/100 Mbit/s for Ethernet1; 10/100/1000 Mbit/s for Ethernet2
Communication port protocolEtherNet/IP adapter; EtherNet/IP scanner; Modbus TCP client/server; Modbus TCP IO scanner; Modbus TCP NVL; Ethernet RSTP; Modbus SL client/server; Modbus SL IO scanner; Modbus SL modem management; Machine Expert; ASCII manager; ASCII modem management
Maximum number of connected devicesEtherNet/IP: 64; Modbus TCP: 64; Modbus TCP/EtherNet/IP: 96
Communication serviceMQTTs; OPC UA server (Encrypt); HTTPs Methods (API); Web server; Web visu; TLS 1.2; TLS 1.3; SNTP; NTP client/server; FTP client/server; FTPs server; SQL client (remote access); DHCP client; DHCP server; DNS client; POP3s client; SMTP client; SNMP client/server
Local signalling1 LED (green/red) for PWR; 1 LED (green/red) for RUN; 1 LED (green/red) for ERROR (fault); 1 LED (green/red) for stop forced; 1 LED (green/red) for I/O error (I/O); 1 LED (green/orange) for SD card activity; 1 LED (green/orange) for SL activity; 1 LED (green/red) for ETH1 state; 1 LED (green/red) for ETH2 state; 1 LED (green/red) for EIP MS; 1 LED (green/red) for EIP NS
Electrical connectionremovable spring terminal blockfor inputs and outputs; removable spring terminal blockfor connecting the 24 V DC power supply
Maximum cable distance between devicesShielded cable:
InsulationBetween fast input and internal logic at 550 V AC; Non-insulated between inputs; Between fast output and internal logic at 500 V AC; Non-insulated between outputs; Between input and output at 500 V AC; Between supply and internal logic at 500 V AC; Non-insulated between supply and ground
Surge withstand1 kV power lines (DC) common mode conforming to IEC 61000-4-5; 1 kV shielded cable common mode conforming to IEC 61000-4-5; 0.5 kV relay output differential mode conforming to IEC 61000-4-5; 1 kV input common mode conforming to IEC 61000-4-5; 1 kV transistor output common mode conforming to IEC 61000-4-5
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit
Height100 mm
Depth90 mm
Width125 mm
Net weight0.655 kg
Contractual warranty
Warranty (in months)18
Environment
StandardsUL 61010-1; UL 61010-2-201; CSA C22.2 No 61010-1; CSA C22.2 No 61010-2-201; CSA C22.2 No 213; ANSI/ISA 12-12-01; IEC 61131-2
Product certificationsCE; cULus; cULus HazLoc Class I Division 2 CSA 22-2 No 213; RCM; EAC; Achilles; KC
Resistance to electrostatic discharge4 kV on contact conforming to IEC 61000-4-2; 8 kV on air conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3; 1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3
Resistance to fast transients2 kV (power lines) conforming to IEC 61000-4-4; 1 kV (Ethernet line) conforming to IEC 61000-4-4; 1 kV (serial link) conforming to IEC 61000-4-4; 1 kV (input) conforming to IEC 61000-4-4; 1 kV (transistor output) conforming to IEC 61000-4-4
Resistance to conducted disturbances10 V 0.15...80 MHz conforming to IEC 61000-4-4; 3 V 0.1...80 MHz; 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)
Electromagnetic emissionConducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011; Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011; Radiated emissions - test level: 40 dBµV/m at 30…230 kHz conforming to IEC 55011; Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011; Radiated emissions at 230…1000 MHz conforming to IEC 55011
Immunity to microbreaks0.01 ms
Ambient air temperature for operation-20…60 °C (horizontal installation); -20…50 °C (vertical installation); -20…45 °C (flat mounting)
Ambient air temperature for storage-40…85 °C
Relative humidity10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)
IP degree of protectionIP20
Pollution degree2
Operating altitude0...2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 2…8.4 Hz on symmetrical rail; 1 gn at 8.4…200 Hz on symmetrical rail; 3.5 mm at 2…8.4 Hz on panel mounting; 1 gn at 8.4…200 Hz on panel mounting
Shock resistance15 gn for 11 ms
Logistical informations
Country of originID
Main
Range of productLogic/motion controller - Modicon M262
Product or component typeLogic controller
[Us] rated supply voltage24 V DC - 15...20 %
Discrete I/O number8
Upstream connectivityIIoT-ready machine to cloud; Connected machine to plant
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.100 cm
Package 1 Width14.100 cm
Package 1 Length18.900 cm
Package 1 Weight822.000 g
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.440 kg
Unit Type of Package 3P06
Number of Units in Package 364
Package 3 Height73.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight69.010 kg


Product data sheet
Datasheet for Schneider Electric TM262L01MESE8T, EAN: 3606482452442

Questions & answers

What is the delivery time of Schneider Electric TM262L01MESE8T PLC control Modicon M262 IIoT-capable 5 ns/instruction?

The article Schneider Electric TM262L01MESE8T PLC control Modicon M262 IIoT-capable 5 ns/instruction is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 34 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric TM262L01MESE8T to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Schneider Electric TM262L01MESE8T PLC control Modicon M262 IIoT-capable 5 ns/instruction always at the best possible price. We can give you a discount of 2% on Schneider Electric TM262L01MESE8T PLC control Modicon M262 IIoT-capable 5 ns/instruction if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Schneider Electric TM262L01MESE8T PLC controller IIoT-enabled
Schneider Electric TM262L01MESE8T PLC control Modicon M262 IIoT-capable 5 ns/instruction
831,11 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Schneider Electric TM262L01MESE8T PLC controller IIoT-enabled
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
4 + 9 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.