Product information for Schneider Electric R9DX01616:
Applications
The Resi9 RCBO is intended for use in distributions in residential construction and small installations where a high protection standard for people and electrical installations is required. It is suitable for earthing systems TN-S, TT, TN-C-S, and TN. The protection rating IP20 and IP20 (modular housing) along with the IK05 rating make the device suitable for indoor use, with the IP20 protection rating providing higher mechanical and touch-safe coverage when used modularly. The operating temperature ranges from -25 °C to 60 °C, enabling use in various environments. The maximum operating altitude is 2000 m above sea level, and the relative humidity can reach up to 95 % at 55 °C.
Functions and Equipment in Detail
The device features a thermomagnetic tripping mechanism with B-curve characteristics, enabling precise response to overloads and short circuits. The magnetic tripping threshold lies between 3- and 5-times the rated current. The residual current protection is voltage-independent and trips immediately at a fault current of 30 mA. The Type A protection class ensures that direct current fault currents up to 6 mA are detected, which is important for installations with electronic devices. The contact position indicator shows the state of the switch, with a separate red indicator visible when the residual current protection trips and another when the overcurrent protection trips. The test button, marked with a “T”, enables functional testing of the device.
Technology Explained Simply
The Resi9 RCBO combines two protection functions in one device: residual current protection (FI) and overcurrent protection (LS). The FI protection disconnects at a fault current of 30 mA to prevent electrical hazards to people. The LS protection safeguards against overload and short circuit, with the thermal component detecting slow overloads and the magnetic component reacting to sudden high currents. The device has a breaking capacity of 6000 A at 230 V AC, providing high safety during short circuit events. The rated insulation voltage is 440 V AC, and the impulse voltage withstand is 4 kV, ensuring high electrical strength. The rated breaking capacity complies with standard EN/IEC 61009-2-1.
Compatibility and Accessories
The device is mounted on DIN rails by clipping and features a connection pitch of 9 mm. It is compatible with comb rails and distribution blocks. The terminals consist of tunnel terminals suitable for solid cable (1–16 mm²), flexible cable (1–10 mm²), and flexible cable with wire end ferrules (1–10 mm²). The wire stripping length is 12 mm, and the tightening torque is 2 Nm. The mechanical and electrical service life is 10,000 cycles each. The device is sealable and can be secured with padlocks, enabling secure protection.
Mounting and Installation
Mounting is done on a DIN rail, with the device being 18 mm wide and occupying two 9-mm pitches. Dimensions are 91 mm height, 18 mm width, and 69 mm depth. The device is intended for use in distributions and is used as an outgoing switch. Mounting is done by clipping onto the rail, with terminals connectable at the top or bottom. Pollution degree class 2 and overvoltage category III account for typical environmental conditions in distributions.
Advantages in Operation
The Resi9 RCBO offers compact, reliable, and maintenance-friendly protection. The integrated test button enables easy functional checking. The clear indication of the tripping cause (overcurrent or residual current) simplifies fault diagnosis. The high mechanical and electrical service life of 10,000 cycles ensures long-term use. Compatibility with comb rails and distribution blocks, along with the possibility of securing with padlocks and sealing, increases flexibility and safety in operation. The device is white (RAL 9003) and visually integrates into standard distributions.
Residual current circuit breaker, overcurrent protection, Type A, thermomagnetic, DIN rail, IP20 IP20
More spare projector bulbs for your Mitsubishi Beamer
| Additional features | |
| Device position in system | Outlet |
| Network frequency | 50 Hz |
| [Ue] Operational rated voltage | 230 V AC |
| Magnetic trip threshold | 3 - 5 x In0AC |
| Earth fault trip technology | Voltage-independent |
| [Ics] Rated operational breaking capacity | 6000 A 100 % - 230 V AC |
| Rated breaking force and rated power | Icn 6000 A at 230 V AC corresponds to EN/IEC 61009-2-1 |
| Limiting class | 3 |
| [Ui] Rated insulation voltage | 440 V AC |
| [Uimp] Rated impulse voltage withstand | 4 kV |
| Inrush current | 250 A |
| Control type | Toggle switch |
| Local signalling | ON/OFF indicator |
| Mounting mode | Plug-in |
| Mounting bracket | DIN rail |
| Terminal pitch | 9 mm |
| 9-mm pitch | 2 |
| Height | 91 mm |
| Width | 18 mm |
| Depth | 69 mm |
| Product weight | 125 g |
| Colour | White (RAL 9003) |
| Mechanical life | 10000 cycles |
| Electrical lifetime | 10000 cycles |
| Description of locking options | Padlock; Sealing possible |
| Connections - terminals | Tunnel terminals (top or bottom) - 1 - 16 mm² - solid; Tunnel terminals (top or bottom) - 1 - 10 mm² - stranded; Tunnel terminals (top or bottom) - 1 - 10 mm² - stranded with ferrule |
| Wire stripping length | 12 mm for top or bottom connection |
| [M] tightening torque | 2 Nm top or bottom |
| Earth fault protection | Integrated |
| Contact position indicator | |
| Compatibility of comb rails and distribution blocks | |
| Provisions for padlocks | |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Main features | |
| Product series | Resi9 |
| Product name | Resi9 RCBO |
| Product or component type | Residual current circuit breaker with overcurrent protection (FI/LS) |
| Device short name | Resi9 RCBO |
| Device application | Distribution |
| Pole description | 1P + N |
| Neutral position | Left |
| Number of protected poles | 1 |
| [In] Rated current | 16 A at 30 °C |
| Earthing system | TN-S; TT; TN-C-S; TN |
| Type of network | AC |
| Trigger technology | Thermal-magnetic |
| Cam disc | B |
| Earth fault sensitivity | 30 mA |
| Earth fault protection time delay | Instantaneous |
| Earth fault protection class | Type A |
| Breaking capacity | 6000 A Icn at 230 V AC 50 Hz conforms to EN/IEC 61009-2-1 |
| Conformity marking | VDE; KEMA |
| Suitability for insulation | |
| Mounting | |
| Standards | EN/IEC 61009-1; EN/IEC 61009-2-1 |
| Degree of protection (IP) | IP20; IP40 (modular housing) |
| Degree of protection (IK) | IK05 |
| Pollution degree | 2 |
| Over voltage category | III |
| Electromagnetic compatibility | 8/20 µs impulse resistance, 250 A corresponds to EN/IEC 61009-2-1 |
| Drip-proof | 2 corresponds to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 2.000 m |
| Operating ambient temperature | -25…60 °C |
| Ambient temperature during storage | -40…80 °C |
| Packaging units | |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 2,300 cm |
| VPE 1 width | 8,600 cm |
| VPE 1 length | 11,300 cm |
| Packaging weight (Lbs) | 146,000 g |
| VPE 2 type | S02 |
| VPE 2 quantity | 45 |
| VPE 2 height | 15,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 6,764 kg |
| VPE 3 type | P12 |
| VPE 3 quantity | 720 |
| VPE 3 height | 45,000 cm |
| VPE 3 width | 80,000 cm |
| VPE 3 length | 120,000 cm |
| VPE 3 weight | 124,000 kg |
Questions & answers
What is the delivery time of Schneider Electric R9DX01616 Schneider FI/LS-switch Resi9 1P+N 1TE wide (18mm) 16A 30mA?
The article Schneider Electric R9DX01616 Schneider FI/LS-switch Resi9 1P+N 1TE wide (18mm) 16A 30mA is currently in stock
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric R9DX01616 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric R9DX01616 Schneider FI/LS-switch Resi9 1P+N 1TE wide (18mm) 16A 30mA always at the best possible price. We can give you a discount of 2% on Schneider Electric R9DX01616 Schneider FI/LS-switch Resi9 1P+N 1TE wide (18mm) 16A 30mA if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.