Schneider Electric LU2BB0BL power supply 32 A 24 V DC control missing connections
|
-7% 309,48 EUR 331,43 EUR |
|||||||||||
|
incl. 9,28 EUR copper surcharge ( 368,28 EUR incl. VAT ) ≈ £259.03 | ≈ $340.12 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 25 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1771730 | ||||||||||
| Mfg Part No: | LU2BB0BL | ||||||||||
| UPC/EAN: | 3389110363135 | ||||||||||
| Weight: | 1.283 kg | ||||||||||
| Type: | LU2BB0BL | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Schneider Electric LU2BB0BL:
| Complementary | |
| Typical current consumption | 120 mA at 24 V DC I maximum while closing; 120 mA at 24 V DC I rms sealed |
| Heat dissipation | 3 W for control circuit with LUCA, LUCB, LUCC, LUCD; 1.8 W for control circuit with LUCM |
| Inrush restraint duration | 15 ms DC |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Operating time | 150 ms with change of direction for power circuit; 75 ms without change of direction for power circuit; 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit; 75 ms closing with LUCM for control circuit; 70 ms closing with LUCA, LUCB, LUCC, LUCD for control circuit |
| Mechanical durability | 15 Mcycles |
| maximum operating rate | 3600 cyc/h |
| Product certifications | CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine |
| Standards | EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-6-2 (pollution degree 3); 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-6-2 |
| Safe separation of circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N |
| Fixing mode | Clipped (DIN rail); Screw-fixed (plate) |
| Connections - terminals | Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid; Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end; Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end; Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end; Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid; Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end; Control circuit: without connection |
| Tightening torque | Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm; Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm |
| Width | 45 mm |
| Height | 224 mm |
| Depth | 126 mm |
| Net weight | 1.25 kg |
| Compatibility code | LU2B |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Environment | |
| IP degree of protection | IP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone) |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD |
| Ambient air temperature for storage | -40…85 °C |
| Fire resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12 |
| Operating altitude | 2000 m |
| Shock resistance | 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27 |
| Vibration resistance | 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27 |
| Resistance to electrostatic discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2 |
| Resistance to fast transients | 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
| Resistance to radiated fields | 10 V/m 3 conforming to IEC 61000-4-3 |
| Immunity to radioelectric fields | 10 V conforming to IEC 61000-4-6 |
| Immunity to microbreaks | 3 ms for control circuit |
| Immunity to voltage dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
| Logistical informations | |
| Country of origin | FR |
| Main | |
| Range | TeSys |
| Product name | TeSys Ultra |
| Device short name | LU2B |
| Product or component type | Reversing power base |
| Device application | Motor control; Motor protection |
| Product compatibility | Control unit LUC.X6BL; Control unit LUC.1XBL; Control unit LUC.05BL; Control unit LUC.12BL; Control unit LUC.18BL; Control unit LUC.32BL |
| Poles description | 3P |
| [Ue] rated operational voltage | 690 V AC for power circuit |
| Network frequency | 40...60 Hz |
| [Ith] conventional free air thermal current | 32 A |
| [Ie] rated operational current | 28.5 A at |
| Utilisation category | AC-43; AC-44; AC-41 |
| [Ics] rated service breaking capacity | 50 kA at 230 V; 50 kA at 440 V; 10 kA at 500 V; 4 kA at 690 V |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1; type mirror contact (1 NC) conforming to IEC 60947-1 |
| [Uc] control circuit voltage | 24 V DC |
| Control circuit voltage limits | 14.5 V DC drop-out; 20...27 V DC in operation |
| Suitability for isolation | |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 15.000 cm |
| Package 1 Length | 25.500 cm |
| Package 1 Weight | 1.283 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 12.028 kg |
Questions & answers
What is the delivery time of Schneider Electric LU2BB0BL power supply 32 A 24 V DC control missing connections?
The article Schneider Electric LU2BB0BL power supply 32 A 24 V DC control missing connections is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 25 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric LU2BB0BL to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric LU2BB0BL power supply 32 A 24 V DC control missing connections always at the best possible price. We can give you a discount of 2% on Schneider Electric LU2BB0BL power supply 32 A 24 V DC control missing connections if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Schneider Electric LU2BB0BL power supply 32 A 24 V DC control missing connections we can offer you a price of 295,97 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
Schneider Electric LAD90 label holder plug-in 18x8 mm
Standard contactors 0.06 -75 kW In addition to an attractive and functional design, the TeSys D contactors offer quick and easy installation with a narrow width of 45 or 55 mm. They meet international ...Lieske Part No.: 585386 Mfg Part No: LAD90 |
49,88 EUR 51,98 EUR
![]() ≈ £41.75 | ≈ $54.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
|
Fitting accessory for Schneider Electric LU2BB0BL power supply 32 A 24 V DC control missing connections
|
Schneider Electric LAD90 label holder plug-in 18x8 mm
Standard contactors 0.06 -75 kW In addition to an attractive and functional design, the TeSys D contactors offer quick and easy installation with a narrow width of 45 or 55 mm. They meet international ...Lieske Part No.: 585386 Mfg Part No: LAD90 |
49,88 EUR 51,98 EUR
![]() ≈ £41.75 | ≈ $54.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
|