| Complementary | |
| Network frequency | 0...400 Hz |
| Mounting support | Plate, with specific accessories; Rail, with specific accessories; Under contactor |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Permissible current | 3 A at 120 V AC-15 for signalling circuit; 0.22 A at 125 V DC-13 for signalling circuit |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit; 4 A BS for signalling circuit |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Control type | Red push-button: stop; Blue push-button: reset |
| Temperature compensation | -20…60 °C |
| Connection pitch | 17.5 mm |
| Connections - terminals | Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end; Power circuit: lugs-ring terminals |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals; Power circuit: 6 N.m - on lugs-ring terminals |
| Height | 70 mm |
| Width | 55 mm |
| Depth | 123 mm |
| Net weight | 0.375 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Environment | |
| Climatic withstand | conforming to IACS E10 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Ambient air temperature for storage | -60…70 °C |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7; Vibrations: 4 gn conforming to IEC 60068-2-6 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1 |
| Product certifications | IEC; UL; CSA; CCC; EAC; DNV-GL; RMRS; EU-RO MR; LROS (Lloyds register of shipping); UKCA |
| Logistical informations | |
| Country of origin | FR |
| Main | |
| Range | TeSys; TeSys Deca |
| Product name | TeSys LRD; TeSys Deca |
| Product or component type | Differential thermal overload relay |
| Device short name | LRD |
| Relay application | Motor protection |
| Product compatibility | LC1D50A; LC1D65A |
| Network type | DC; AC |
| Thermal overload class | Class 20 conforming to IEC 60947-4-1 |
| Thermal protection adjustment range | 48…65 A |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to CSA; Power circuit: 600 V conforming to UL; Power circuit: 690 V conforming to IEC 60947-4-1 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.400 cm |
| Package 1 Width | 14.800 cm |
| Package 1 Length | 19.800 cm |
| Package 1 Weight | 379.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 13 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.216 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 208 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 91.456 kg |
Questions & answers
What is the delivery time of Schneider Electric LRD365L6 motor protection relay 48-65 A 1NO1NC class 20 ring cable lug?
The article Schneider Electric LRD365L6 motor protection relay 48-65 A 1NO1NC class 20 ring cable lug is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 15 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric LRD365L6 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric LRD365L6 motor protection relay 48-65 A 1NO1NC class 20 ring cable lug always at the best possible price. We can give you a discount of 2% on Schneider Electric LRD365L6 motor protection relay 48-65 A 1NO1NC class 20 ring cable lug if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Schneider Electric LRD365L6 motor protection relay 48-65 A 1NO1NC class 20 ring cable lug we can offer you a price of 336,65 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Schneider Electric LRD365L6 motor protection relay 48-65 A 1NO1NC class 20 ring cable lug
|
Schneider Electric LAD96570 finger protection IP20 for cable lug terminals
Standard contactors 0.06 -75 kW In addition to an attractive and functional design, the TeSys D contactors offer quick and easy installation with a narrow width of 45 or 55 mm. They meet international ...Lieske Part No.: 652751 Mfg Part No: LAD96570 |
15,48 EUR 16,14 EUR
![]() ≈ £12.96 | ≈ $17.01
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric LAD96566 terminal block ring cable lugs for LRD3136-3656
Standard contactors 0.06 -75 kW In addition to an attractive and functional design, the TeSys D contactors offer quick and easy installation with a narrow width of 45 or 55 mm. They meet international ...Lieske Part No.: 767148 Mfg Part No: LAD96566 |
14,39 EUR 15,00 EUR
![]() ≈ £12.04 | ≈ $15.81
Made to order · Delivery time approx. 15 workdaysinfo_outline
|