Schneider Electric LC1K06106FLS207 Contactors , 3-pole+1NO, 2.2kW/400V/AC3, 6A
|
61,22 EUR |
|
|
incl. 5,75 EUR copper surcharge ( 72,85 EUR incl. VAT ) ≈ £51.30 | ≈ $67.22 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 19 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1017129 |
| Mfg Part No: | LC1K06106FLS207 |
| UPC/EAN: | 3606480920608 |
| Weight: | 0.24 kg |
More spare projector bulbs for your Panasonic Beamer
| Additional features | |
| Application category | AC-3; AC-3e; AC-4 |
| Pole description | 3P |
| Pole contact composition | 3 S |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 6 A (at |
| Control circuit type | DC low power consumption |
| [Uc] control circuit voltage | 110 V DC |
| Motor power (kW) | 1.5 kW at 220 - 230 V AC 50/60 Hz AC-3; 2.2 kW at 380 - 415 V AC 50/60 Hz AC-3; 3 kW at 440/690 V AC 50/60 Hz AC-3; 1.5 kW at 220 - 230 V AC 50/60 Hz AC-3e; 2.2 kW at 380 - 415 V AC 50/60 Hz AC-3e; 3 kW at 440/690 V AC 50/60 Hz AC-3e; 1.5 kW at 220 - 230 V AC 50/60 Hz AC-4; 2.2 kW at 380 - 415 V AC 50/60 Hz AC-4; 3 kW at 440/690 V AC 50/60 Hz AC-4 |
| Configuration of auxiliary contacts | 1 S |
| [Uimp] Rated impulse voltage withstand | 8 kV |
| Over voltage category | III |
| [Ith] conventional thermal current in free air | 20 A (at 60 °C) for circuit; 10 A (at 50 °C) for signal circuit |
| [Irms] Rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signal circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220 - 230 V corresponds to IEC 60947; 110 A at 380 - 400 V corresponds to IEC 60947; 110 A at 415 V corresponds to IEC 60947; 110 A at 440 V corresponds to IEC 60947; 80 A at 500 V corresponds to IEC 60947; 70 A at 660 - 690 V corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 90 A 50 °C - 1 s for circuit; 85 A 50 °C - 5 s for circuit; 80 A 50 °C - 10 s for circuit; 60 A 50 °C - 30 s for circuit; 45 A 50 °C - 1 min for circuit; 40 A 50 °C - 3 min for circuit; 20 A 50 °C - >= 15 min. for circuit; 80 A - 1 s for signal circuit; 90 A - 500 ms for signal circuit; 110 A - 100 ms for signal circuit |
| Associated fuse | 25 A gG at |
| Average impedance | 3 MOhm - Ith 20 A 50 Hz for circuit |
| [Ui] Rated insulation voltage | Power circuit: 690 V according to IEC 60947-4-1; signal circuit: 690 V according to IEC 60947-4-1; signal circuit: 690 V according to IEC 60947-5-1; power circuit: 750 V according to VDE 0110 Group C; power circuit: 690 V according to BS 5424; power circuit: 690 V according to NF C 20-040 |
| Safety cover | With |
| Insulation resistance | > 10 MΩ for signal circuits |
| Absorption power in W | 1.8 W (at 20 °C) |
| Holding power consumption in W | 1.8 W at 20 °C |
| Heat emission | 1,8 W |
| Control circuit voltage limits | Operation: 0.7 - 1.3 Uc (at = 0.10 Uc (at |
| Connections - terminals | Power circuit: ring terminal connectors (outer diameter: 7 mm) |
| Max. operating rate | 3600 cyc/h |
| Coil technology | With integrated suppression unit |
| Type of auxiliary contacts | Type instantaneous 1 S |
| Min. switching current | 5 mA for signal circuit |
| Min. switching voltage | 17 V for signal circuit |
| Mounting bracket | Plate; rail |
| Tightening moment | Circuit: 0.8…1.3 Nm - on ring terminal lugs - with flat screwdriver 3.2 mm Ø 6; Circuit: 0.8…1.3 Nm - on ring terminal lugs - with Phillips screwdriver 3.2 mm No. 2; Circuit: 0.8…1.3 Nm - on ring terminal lugs position No. 2 |
| Operating time | 10 - 20 ms coil de-energisation and NO opening; 30 - 40 ms coil energisation and NO closing |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Non-overlapping distance | 0,5 mm |
| Mechanical life | 30 Mcycles |
| Electrical lifetime | 1.3 Mcycles 6 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Product weight | 0,235 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Main features | |
| Product series | TeSys |
| Product or component type | Contactor |
| Device short name | LC1K |
| Device application | Control |
| Application of contactor | Motor control |
| Mounting | |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No. 60947-4-1; JIS C8201-4-1 |
| Product certifications | CB certification; CCC; UL; CSA; EAC; CE; UKCA |
| Degree of protection (IP) | IP20 corresponds to VDE 0106 |
| Coating | TC corresponds to IEC 60068; TC corresponds to DIN 50016 |
| Ambient temperature during storage | -50…80 °C |
| Device ambient temperature | -40…70 °C at Uc |
| Operating altitude | 2,000 m without derating |
| Flame retardancy | V0 corresponds to UL 94 |
| Packaging units | |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 5,7 cm |
| VPE 1 width | 4,8 cm |
| VPE 1 length | 6,2 cm |
| Packaging weight (Lbs) | 240,0 g |
Questions & answers
What is the delivery time of Schneider Electric LC1K06106FLS207 Contactors , 3-pole+1NO, 2.2kW/400V/AC3, 6A?
The article Schneider Electric LC1K06106FLS207 Contactors , 3-pole+1NO, 2.2kW/400V/AC3, 6A is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 19 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric LC1K06106FLS207 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric LC1K06106FLS207 Contactors , 3-pole+1NO, 2.2kW/400V/AC3, 6A always at the best possible price. We can give you a discount of 2% on Schneider Electric LC1K06106FLS207 Contactors , 3-pole+1NO, 2.2kW/400V/AC3, 6A if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.