Schneider Electric LC1D150A6LSE Contactor TeSys Deca LC1D 3-pole +1NO+1NC 75 kW 150 A
|
1.912,01 EUR |
|
|
incl. 81,12 EUR copper surcharge ( 2.275,29 EUR incl. VAT ) ≈ £1,600.35 | ≈ $2,101.30 plus delivery charges: 148,00 € |
|
| Made to order · Delivery time approx. 65 workdaysinfo_outline | |
| Sales unit: 4 pieces | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1857963 |
| Mfg Part No: | LC1D150A6LSE |
| UPC/EAN: | 3606487155911 |
| Weight: | 10.135 kg |
The item price shown refers to 4 pieces Schneider Electric LC1D150A6LSE
| Complementary | |
| Motor power hp | 40 hp at 200/208 V 60 Hz; 50 hp at 230/240 V 60 Hz; 100 hp at 460/480 V 60 Hz; 125 hp at 575/600 V 60 Hz |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
| Irms rated making capacity | 1885 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 1440 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 350 A 40 °C - 10 min for power circuit; 600 A 40 °C - 1 min for power circuit; 1280 A 40 °C - 10 s for power circuit; 1800 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 160 A aM at |
| Average impedance | 0.45 mOhm - Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole | 8 W AC-3; 8 W AC-3e; 22 W AC-1 |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| Electrical durability | 0.85 Mcycles 150 A AC-3 at Ue |
| Control circuit type | AC at 50/60 Hz; DC |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.8 Uc Min...1.1 Uc Max (-40…60 °C):operational AC/DC; 0.1 Uc Max (-40…60 °C):drop-out AC/DC |
| Inrush power in VA | 170 VA (at 20 °C) |
| Inrush power in W | 120 W (at 20 °C) |
| Hold-in power consumption in VA | 16.5 VA (at 20 °C) |
| Hold-in power consumption in W | 5.1 W at 20 °C |
| Heat dissipation | 3 W at 20 °C |
| Operating time | 10...80 ms opening; 20...90 ms closing |
| Maximum operating rate | 2400 cyc/h at 60 °C; 3600 cyc/h at Uc at 20 ºC |
| Tightening torque | Power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 16.67...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Environment | |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; JIS C8201-4-1; JIS C8201-5-1; GB/T 14048.4; GB/T 14048.5 |
| Product certifications | CB Scheme; CCC; cULus; CE; UKCA; EU-RO-MR by DNV-GL |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | None conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C operation; 60…70 °C with derating; -60…80 °C storage |
| Operating altitude | 0...3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-11 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) conforming to IEC 60068-2-6; Vibrations contactor closed (4 Gn, 5...300 Hz) conforming to IEC 60068-2-6; Shocks contactor open (10 Gn for 11 ms) conforming to IEC 60068-2-27; Shocks contactor closed (15 Gn for 11 ms) conforming to IEC 60068-2-27 |
| Height | 152 mm |
| Width | 99 mm |
| Depth | 155 mm |
| Net weight | 2.2 kg |
| Logistical informations | |
| Country of origin | CN |
| Main | |
| Range | TeSys Deca |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4; DC-1; DC-3; DC-5 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 150 A (at |
| [Uc] control circuit voltage | 200...500 V AC 50/60 Hz; 200...500 V DC |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.700 cm |
| Package 1 Width | 18.500 cm |
| Package 1 Length | 19.400 cm |
| Package 1 Weight | 2.444 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 10.135 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 32 |
| Package 3 Height | 73.500 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 91.078 kg |
Questions & answers
What is the delivery time of Schneider Electric LC1D150A6LSE Contactor TeSys Deca LC1D 3-pole +1NO+1NC 75 kW 150 A?
The article Schneider Electric LC1D150A6LSE Contactor TeSys Deca LC1D 3-pole +1NO+1NC 75 kW 150 A is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 65 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric LC1D150A6LSE to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric LC1D150A6LSE Contactor TeSys Deca LC1D 3-pole +1NO+1NC 75 kW 150 A always at the best possible price. We can give you a discount of 2% on Schneider Electric LC1D150A6LSE Contactor TeSys Deca LC1D 3-pole +1NO+1NC 75 kW 150 A if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
How many units does the article contain?
Schneider Electric LC1D150A6LSE Contactor TeSys Deca LC1D 3-pole +1NO+1NC 75 kW 150 A is offered by us in a sales unit of 4 pieces If you need a larger quantity, you can contact us at any time. We will make a special offer for you