Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
Schneider Electric Logo

Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V

Your rating:
Average rating
product review for Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V
( 4 / 5 ) 2 ratings
Schneider Electric ATV930D15S6X
This image may differ from the desired article.
4.880,15 EUR 5.085,63 EUR
( 5.807,38 EUR incl. VAT )
≈ £4,084.69  |  ≈ $5,363.28
plus delivery charges: 100,00 €
Made to order · Delivery time approx. 35 workdaysinfo_outline
1x Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V
Datasheet:file_download Download
Lieske Part No.:1866062
Mfg Part No: ATV930D15S6X
UPC/EAN: 3606481325013
Weight:8.8 kg
Type:ATV930D15S6X
Graduated prices net
From piecesPrice per pieces
24.770,35 EUR
44.660,54 EUR
64.550,74 EUR
84.440,94 EUR

Product information for Schneider Electric ATV930D15S6X:

Frequency converter, Altivar Process ATV900, ATV930, 20 HP, 600 V, IP21.

Additional features
Electrical connectionControl: Screw terminal 0.5 - 1.5 mm²/AWG 20 - AWG 16; Motor: Screw terminal 6 - 10 mm²/AWG 10 - AWG 8; Wiring side: Screw terminal 6 mm²/AWG 10; DC bus: Screw terminal 6 mm²/AWG 10
Transmission speed10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8; 9.6; 19.2; 38.4 kBit/s for Modbus, serial
Swap modeHalf-duplex, full-duplex, auto-negotiation Ethernet IP/Modbus TCP
Data format8 bits, configurable to odd, even, or no parity for Modbus, serial
Polarisation typeNo impedance for Modbus, serial
Number of addresses1…247 for Modbus, serial
SupplyExternal power supply for digital inputs: 24 V DC (19…30 V)
Local signallingLocal diagnostics: 3 LEDs (single- or dual-colour); Presence of voltage: 1 LED (red); Status of integrated communication: 3 LEDs (dual-colour); Status of communication module: 4 LEDs (dual-colour)
Input compatibilityDI1...DI8: Discrete input Level 1 PLC according to IEC 61131-2; DI7, DI8: Pulse input Level 1 PLC according to IEC 65A-68; STOA, STOB: Discrete input Level 1 PLC according to IEC 61131-2
Discrete input logicPositive logic (source) (DI1...DI8), 5 V (position 0), 11 V (position 1); Negative logic (sink) (DI1...DI8), 16 V (position 0), 10 V (position 1); Positive logic (source) (DI7, DI8), 0.6 V (position 0), 2.5 V (position 1); Positive logic (source) (STOA, STOB), 5 V (position 0), 11 V (position 1)
Sampling duration2 ms +/- 0.5 ms (DI1...DI8) - discrete input; 5 ms +/- 1 ms (DI7, DI8) - pulse input; 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 5 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 with temperature variation of 60 °C analog input; +/-1 % AQ1, AQ2 with temperature variation of 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output
Update timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Insulationbetween power and control terminals
Number of discrete inputs10
Discrete input typeDI1...DI8 programmable, 24 V DC (= 30 V), impedance: 3.5 kOhm; DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (= 30 V); STOA, STOB Safe Torque Off (safely switched-off torque), 24 V DC (= 30 V), impedance: > 2.2 kOhm
Number of discrete outputs2
Discrete output typeDigital output DQ+ 0…1 kHz = 30 V DC 100 mA; Programmable as pulse output DQ+ 0…30 kHz = 30 V DC 20 mA; Digital output DQ- 0…1 kHz = 30 V DC 100 mA
Number of analog inputs3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0 - 10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0 - 20 mA / 4 - 20 mA, impedance: 250 Ohm, resolution 12 bits
Number of analogue outputs2
Analog output typeSoftware-configurable voltage AQ1, AQ2: 0 - 10 V DC resistance 470 Ohm, resolution 10 bit; Software-configurable current AQ1, AQ2: 0 - 20 mA resistance 500 Ohm, resolution 10 bit
Relay output number3
Relay output typeConfigurable relay logic R1: Fault relay normally open/normally closed contact, electrical life 100000 cycles; Configurable relay logic R2: Sequence relay no, electrical life 1000000 cycles; Configurable relay logic R3: Sequence relay no, electrical life 1000000 cycles
Min. switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Physical interfaceEthernet; 2-wire RS 485
Connection type2 RJ45; 1 RJ45
Access methodSlave Modbus TCP
Transmission frameRTU
4-quadrant operation possibleCorrect
Control profile for asynchronous motorsOptimized torque mode; constant standard torque; variable standard torque
Control profile for synchronous motorsPermanent magnet motor; Synchronous reluctance motor
Max. output frequency599 Hz
Acceleration and deceleration rampsLinearly separately adjustable from 0.01 - 9999 s; S, U or user-defined
Motor slip compensationDeactivatable; Adjustable; Not available in permanent magnet motor control; Automatic, independent of load
Clock frequency2 - 16 kHz adjustable; 4 - 16 kHz with power derating factor
Rated switching frequency4 kHz
Braking to standstillBy direct current injection
Integrated brake chopperCorrect
Max. input current19,6 A
Max. output voltage600,0 V
Apparent power20.4 kVA at 600 V (normal operation); 15.9 kVA at 600 V (heavy-duty operation)
Max. peak current26.4 A for 60 s (normal operation); 27 A for 60 s (heavy-duty operation)
Network frequency50 - 60 Hz
Potential line Isc70 kA
Base load current at high overload18,0 A
Base load current at low overload22,0 A
Power loss in WForced convection: 192 W at 600 V, switching frequency 4 kHz; Natural convection: 136 W at 600 V, switching frequency 4 kHz
With safety function Safely Limited Speed (SLS)Correct
With safety function Safe brake management (SBC/SBT)Correct
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)Correct
With safety function Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)Correct
with safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Quantity per set1
Width171 mm
Height409 mm
Depth236 mm
Product weight5,5 kg
Contractual warranty
Warranty (in months)18
Main features
Product seriesAltivar Prozess ATV900
Product-specific applicationProcess for industry
Product or component typeVariable speed drive
VariantStandard version; with brake chopper
Device applicationIndustrial application
Product applicationAsynchronous motors; synchronous motors
Number of power phases3 phases
Mounting modeSurface mounting
Continuous output current22 A at 4 kHz for normal operation; 18 A at 4 kHz for heavy-duty operation
Communications protocolModbus TCP; Modbus, serial; EtherNet/IP
[UH,nom] Rated operating voltage600 V -15 - +10 %
Relative symmetric net voltage tolerance10 %
Relative symmetric net frequency tolerance5 %
Rated output current22,0 A
EMC filterIntegrated; with EMC plate as option
Degree of protection (IP)IP21
Degree of protectionUL Type 1
Mounting
Insulation resistance> 1 MOhm 500 V DC for 1 minute to ground
Noise level56 dB compliant with 86/188/EEC
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) complies with IEC 60068-2-6; 1 Gn (f= 13…200 Hz) complies with IEC 60068-2-6
Shock resistance15 Gn for 11 ms corresponds to IEC 60068-2-27
Environmental propertiesChemical resistance Class 3C3 according to IEC 60721-3-3; Dust resistance Class 3S3 according to IEC 60721-3-3
Relative humidity5…95 % condensation not permitted corresponds to IEC 60068-2-3
Operating ambient temperature-15…50 °C (without derating); 50…60 °C (with derating factor)
Operating altitude= 1,000 m without power reduction; 1000 - 4800 m with current reduction 1 % per 100 m
Operating positionVertical +/- 10 degrees
Product certificationsCSA; UL; TÜV
StandardsUL 508C; IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1
Construction typeEncapsulated
Electromagnetic compatibilityElectrostatic discharge immunity test Level 3 according to IEC 61000-4-2; Immunity test against radiated high-frequency electromagnetic fields Level 3 according to IEC 61000-4-3; Electrical fast transient burst immunity test Level 4 according to IEC 61000-4-4; 1.2/50 μs - 8/20 μs surge immunity test Level 3 according to IEC 61000-4-5; Conducted radio-frequency electromagnetic field immunity test Level 3 according to IEC 61000-4-6
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock (during operation)150 m/s² at 11 ms
Max. acceleration under vibration load (during operation)10 m/s² at 13 - 200 Hz
Max. deflection under vibration load (during operation)1.5 mm at 2 - 13 Hz
Permissible relative humidity (during operation)Class 3K5 according to EN 60721-3
Cooling air volume103 m3/h
Over voltage categoryIII
Control loopAdjustable PID controller
Pollution degree2
Ambient air temperature during transport-40…70 °C
Ambient temperature during storage-40…70 °C
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height34,0 cm
VPE 1 width22,0 cm
VPE 1 length58,0 cm
Packaging weight (Lbs)8,8 kg


Product data sheet
Datasheet for Schneider Electric ATV930D15S6X, EAN: 3606481325013

Questions & answers

What is the delivery time of Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V?

The article Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 35 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric ATV930D15S6X to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V always at the best possible price. We can give you a discount of 2% on Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 2 pieces of Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V we can offer you a price of 4.770,35 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Fitting accessory for Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V

Schneider Electric VW3A7732 brake resistor, 28 Ohm, 0.3 kW, IP20 Schneider Electric LogoSchneider Electric VW3A7732 brake resistor, 28 Ohm, 0.3 kW, IP20 Braking resistor, for ATV930U30M3-U40M3, ATV930D11N4-D15N4, ATV950D11N4-D15N4, ATV950D11N4E-D15N4E drives. Reference values for a light braking cycle. Power VA 0.3 kW, protection class IP20, ...

Lieske Part No.: 173706
Mfg Part No: VW3A7732
159,13 EUR 165,83 EUR
Schneider Electric VW3A7732 plus VAT
≈ £133.19  |  ≈ $174.88
Made to order · Delivery time approx. 8 workdaysinfo_outline
Schneider Electric GV3P25 motor protection switch 3-pole 17–25 A magnetic trip Schneider Electric LogoSchneider Electric GV3P25 motor protection switch 3-pole 17–25 A magnetic trip TeSys motor protection switch GV3P. Motor protection switch, 3P, thermo-magnetic release. Rated power 11 kW, setting range 16-25 A. With thermal and magnetic releases. Sealable and lockable in the ...

Lieske Part No.: 601918
Mfg Part No: GV3P25
-5% 224,20 EUR 235,64 EUR
Schneider Electric GV3P25 plus VAT
≈ £187.66  |  ≈ $246.40
Made to order · Delivery time approx. 7 workdaysinfo_outline
Schneider Electric VW3A7742 brake resistor 28 Ω 1.1 kW IP20 Schneider Electric LogoSchneider Electric VW3A7742 brake resistor 28 Ω 1.1 kW IP20 Braking resistor, for ATV930D11N4 - D15N4, ATV950D11N4 - D15N4, ATV950D11N4E - D15N4E drives. Reference values for an average braking cycle. Power VA 1.1 kW, protection class IP20, resistance 28 O at ...

Lieske Part No.: 1588158
Mfg Part No: VW3A7742
706,80 EUR 736,56 EUR
Schneider Electric VW3A7742 plus VAT
≈ £591.59  |  ≈ $776.77
Made to order · Delivery time approx. 8 workdaysinfo_outline
Schneider Electric VW3A7752 brake resistor 28 Ohm 5 Schneider Electric LogoSchneider Electric VW3A7752 brake resistor 28 Ohm 5 Braking resistor, for ATV930U40M3, ATV930D11N4 - D15N4, ATV950D11N4 - D15N4, ATV950D11N4E - D15N4E drives. Reference values for a heavy braking cycle (lifting applications). Power VA 5.1 kW, ...

Lieske Part No.: 1770255
Mfg Part No: VW3A7752
1.004,15 EUR 1.046,43 EUR
Schneider Electric VW3A7752 plus VAT
≈ £840.47  |  ≈ $1,103.56
Made to order · Delivery time approx. 8 workdaysinfo_outline
Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Schneider Electric ATV930D15S6X frequency converter 600 V
Schneider Electric ATV930D15S6X ATV930 IP21 20 HP 600 V
4.880,15 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Schneider Electric ATV930D15S6X frequency converter 600 V
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
2 + 4 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.