2.914,60 EUR 3.037,32 EUR |
|||||||||||
|
( 3.468,37 EUR incl. VAT ) ≈ £2,430.78 | ≈ $3,255.61 plus delivery charges |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 713854 | ||||||||||
| Mfg Part No: | ATV212WD15N4 | ||||||||||
| UPC/EAN: | 3606480322242 | ||||||||||
| Weight: | 33 kg | ||||||||||
| Type: | ATV212WD15N4 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Schneider Electric ATV212WD15N4:
| Complementary | |
| Apparent power | 23.2 kVA at 380 V |
| Continuous output current | 30.5 A at 380 V; 30.5 A at 460 V |
| Maximum transient current | 33.6 A for 60 s |
| Speed drive output frequency | 0.5…200 Hz |
| Speed range | 1…10 |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| Local signalling | 1 LED (red) for DC bus energized |
| Isolation | Electrical between power and control |
| Type of cable | Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC; With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
| Electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / 14 AWG; L1/R, L2/S, L3/T: terminal 16 mm² / 4 AWG |
| Tightening torque | 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES); 3 N.m, 26.5 lb.in (L1/R, L2/S, L3/T) |
| Supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 % |
| Sampling duration | 2 ms +/- 0.5 ms F discrete; 2 ms +/- 0.5 ms R discrete; 2 ms +/- 0.5 ms RES discrete; 3.5 ms +/- 0.5 ms VIA analog; 22 ms +/- 0.5 ms VIB analog |
| Response time | FM 2 ms, tolerance +/- 0.5 ms for analog output(s); FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s); FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s); RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s) |
| Accuracy | +/- 0.6 % (VIA) for a temperature variation 60 °C; +/- 0.6 % (VIB) for a temperature variation 60 °C; +/- 1 % (FM) for a temperature variation 60 °C |
| Linearity error | VIA: +/- 0.15 % of maximum value for input; VIB: +/- 0.15 % of maximum value for input; FM: +/- 0.2 % for output |
| Analogue output type | FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits; FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits |
| Discrete output type | Configurable relay logic: (FLA, FLC) NO - 100000 cycles; Configurable relay logic: (FLB, FLC) NC - 100000 cycles; Configurable relay logic: (RY, RC) NO - 100000 cycles |
| Minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| Maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R); 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R); 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R); 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) |
| Discrete input type | F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm; R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm; RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
| Discrete input logic | Positive logic (source) (F, R, RES), = 11 V (state 1); Negative logic (sink) (F, R, RES), >= 16 V (state 0) |
| Dielectric strength | 3535 V DC between earth and power terminals; 5092 V DC between control and power terminals |
| Insulation resistance | >= 1 mOhm 500 V DC for 1 minute |
| Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.024/50 Hz |
| Communication service | Time out setting from 0.1 to 100 s; Write single register (06); Write multiple registers (16) 2 words maximum; Read device identification (43); Monitoring inhibitable; Read holding registers (03) 2 words maximum |
| Option card | Communication card for LonWorks |
| Functionality | Mid |
| Specific application | HVAC |
| Discrete output number | 2 |
| Analogue input number | 2 |
| Analogue input type | VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits; VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits; VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm; VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits |
| Analogue output number | 1 |
| Physical interface | 2-wire RS 485 |
| Connector type | 1 RJ45; 1 open style |
| Transmission rate | 9600 bps or 19200 bps |
| Transmission frame | RTU |
| Number of addresses | 1…247 |
| Data format | 8 bits, 1 stop, odd even or no configurable parity |
| Type of polarization | No impedance |
| Asynchronous motor control profile | Voltage/frequency ratio - Energy Saving, quadratic U/f; Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo); Voltage/frequency ratio, 2 points; Flux vector control without sensor, standard; Voltage/frequency ratio, 5 points |
| Torque accuracy | +/- 15 % |
| Transient overtorque | 120 % of nominal motor torque +/- 10 % for 60 s |
| Acceleration and deceleration ramps | Automatic based on the load; Linear adjustable separately from 0.01 to 3200 s |
| Motor slip compensation | Not available in voltage/frequency ratio motor control; Automatic whatever the load; Adjustable |
| Switching frequency | 6...16 kHz adjustable; 12...16 kHz with derating factor |
| Nominal switching frequency | 12 kHz |
| Braking to standstill | By DC injection |
| Network frequency | 47.5...63 Hz |
| Prospective line Isc | 22 kA |
| Protection type | Overheating protection: drive; Thermal power stage: drive; Short-circuit between motor phases: drive; Input phase breaks: drive; Overcurrent between output phases and earth: drive; Overvoltages on the DC bus: drive; Break on the control circuit: drive; Against exceeding limit speed: drive; Line supply overvoltage and undervoltage: drive; Line supply undervoltage: drive; Against input phase loss: drive; Thermal protection: motor; Motor phase break: motor; With PTC probes: motor |
| Width | 290 mm |
| Height | 560 mm |
| Depth | 315 mm |
| Net weight | 30.3 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Environment | |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Vibration resistance | 1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Environmental characteristic | Classes 3C1 conforming to IEC 60721-3-3; Classes 3S2 conforming to IEC 60721-3-3 |
| Noise level | 57.4 dB conforming to 86/188/EEC |
| Operating altitude | 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m; |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…40 °C (without derating); 40…50 °C (with derating factor) |
| Operating position | Vertical +/- 10 degree |
| Product certifications | NOM 117; C-Tick; UL; CSA |
| Marking | CE |
| Standards | IEC 61800-5-1; IEC 61800-3 environments 1 category C1; IEC 61800-3 environments 1 category C2; IEC 61800-3 environments 1 category C3; IEC 61800-3 environments 2 category C1; IEC 61800-3 environments 2 category C2; IEC 61800-3 environments 2 category C3; CE; UL; CSA; C-Tick N1831; GOST |
| Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Regulation loop | Adjustable PI regulator |
| Ambient air temperature for storage | -25…70 °C |
| Logistical informations | |
| Country of origin | CN |
| Main | |
| Device short name | ATV212 |
| Product destination | Asynchronous motors |
| Network number of phases | 3 phases |
| Motor power kW | 15 kW |
| Motor power hp | 20 hp |
| Supply voltage limits | 323…528 V |
| Supply frequency | 50...60 Hz - 5...5 % |
| Line current | 22.6 A at 480 V; 28.4 A at 380 V |
| Range of product | Altivar 212 |
| Product or component type | Variable speed drive |
| Product specific application | Pumps and fans in HVAC |
| Communication port protocol | Modbus; METASYS N2; BACnet; LonWorks; APOGEE FLN |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| EMC filter | Class C2 EMC filter integrated |
| IP degree of protection | IP55 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 52.000 cm |
| Package 1 Width | 45.000 cm |
| Package 1 Length | 80.000 cm |
| Package 1 Weight | 33.000 kg |
Questions & answers
What is the delivery time of Schneider Electric ATV212WD15N4 frequency converter IP55 15 kW 3ph 480 V EMC class C2?
The article Schneider Electric ATV212WD15N4 frequency converter IP55 15 kW 3ph 480 V EMC class C2 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric ATV212WD15N4 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric ATV212WD15N4 frequency converter IP55 15 kW 3ph 480 V EMC class C2 always at the best possible price. We can give you a discount of 2% on Schneider Electric ATV212WD15N4 frequency converter IP55 15 kW 3ph 480 V EMC class C2 if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 2 pieces of Schneider Electric ATV212WD15N4 frequency converter IP55 15 kW 3ph 480 V EMC class C2 we can offer you a price of 2.827,16 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Schneider Electric ATV212WD15N4 frequency converter IP55 15 kW 3ph 480 V EMC class C2
|
Schneider Electric GV2L32 motor protection switch 3-pole 32 A magnetic release rotary drive
Motor protection switches with thermal and magnetic release These devices are easy to use and set up, with compact and ergonomic products for starter motor and stop motor requirements.Lieske Part No.: 133495 Mfg Part No: GV2L32 |
-5% 197,60 EUR 207,68 EUR
![]() ≈ £164.80 | ≈ $220.72
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Schneider Electric LC1D18F7 contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 110 V 50/60 Hz
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V ...Lieske Part No.: 180348 Mfg Part No: LC1D18F7 |
-6% 77,22 EUR 82,34 EUR
![]() ≈ £64.40 | ≈ $86.25
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Schneider Electric LC1D18M7 Three-phase contactor 3-pole 18 A 220 V 50/60 Hz
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V 18 A, ...Lieske Part No.: 272611 Mfg Part No: LC1D18M7 |
-6% 85,66 EUR 91,35 EUR
![]() ≈ £71.44 | ≈ $95.68
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Schneider Electric LC1D18E7 contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 48 V 50/60 Hz
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V ...Lieske Part No.: 288671 Mfg Part No: LC1D18E7 |
-6% 76,53 EUR 81,60 EUR
![]() ≈ £63.83 | ≈ $85.48
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LC1D18BD contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 24 VDC
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V 18 A, ...Lieske Part No.: 315531 Mfg Part No: LC1D18BD |
-6% 134,75 EUR 143,69 EUR
![]() ≈ £112.38 | ≈ $150.52
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Schneider Electric LC1D18P7 contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 230 VAC
3-pole contactors LC1-DControl voltage 230 V 50/60 Hz - The contactors provide basically two integrated auxiliary contacts: 1 NO + 1 NC Connection type: Screw Motor rating AC-3: 7.5 kW Type: ... Lieske Part No.: 399198 Mfg Part No: LC1D18P7 |
-6% 76,53 EUR 81,60 EUR
![]() ≈ £63.83 | ≈ $85.48
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Schneider Electric LC1D18BL contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 24 VDC
3-pole contactors LC1-DControl voltage 24 V DC Low Power DC 2.4 W Rated voltage 400 V to AC-3. All contactors are essentially for 2 auxiliary switches 1 NO + 1 NC. Connection: screw terminals. Lieske Part No.: 471520 Mfg Part No: LC1D18BL |
-6% 111,15 EUR 118,51 EUR
![]() ≈ £92.70 | ≈ $124.15
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Schneider Electric TCSMCNAM3M002P cable USB/RJ45 ATS22 for connection of a PC
Type: TCSMCNAM3M002PLieske Part No.: 555719 Mfg Part No: TCSMCNAM3M002P |
89,39 EUR 90,08 EUR
![]() ≈ £74.55 | ≈ $99.85
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Schneider Electric LC1D18FE7 contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 115 V 50/60 Hz
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V ...Lieske Part No.: 582945 Mfg Part No: LC1D18FE7 |
-6% 77,60 EUR 82,75 EUR
![]() ≈ £64.72 | ≈ $86.68
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Schneider Electric LC1D18U7 contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 240 VAC
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V 18 A, ...Lieske Part No.: 582997 Mfg Part No: LC1D18U7 |
-6% 77,22 EUR 82,34 EUR
![]() ≈ £64.40 | ≈ $86.25
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Schneider Electric LC1D18ED contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 48 VDC
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V 18 A, ...Lieske Part No.: 627853 Mfg Part No: LC1D18ED |
-6% 136,72 EUR 145,78 EUR
![]() ≈ £114.02 | ≈ $152.72
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Schneider Electric VW3A21212 communication electronic board for VARIA
Kommunikationskarten für Altivar 212. Kommunikationskarten LonWorks.Lieske Part No.: 637784 Mfg Part No: VW3A21212 |
323,00 EUR 336,60 EUR
![]() ≈ £269.38 | ≈ $360.79
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Schneider Electric LC1D18V7 contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 400 V 50/60 Hz
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V ...Lieske Part No.: 779390 Mfg Part No: LC1D18V7 |
84,22 EUR
![]() ≈ £70.24 | ≈ $94.07
Delivery time from supplier's stock (ca.) 5 workdaysinfo_outline
|
|
Schneider Electric LC1D18B7 contactor 3-pole 1NO+1NC 7.5 kW 400 VAC3 18 A 24 V 50/60 Hz
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact + 1 NC contact, rated operating power at AC-3, 400 V 7.5 kW, rated operating current Ie at AC-3, 400 V ...Lieske Part No.: 928730 Mfg Part No: LC1D18B7 |
84,22 EUR
![]() ≈ £70.24 | ≈ $94.07
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|