Schneider Electric ATV12P037F1 frequency converter 0
|
314,45 EUR 327,69 EUR |
|||||||||||
|
( 374,20 EUR incl. VAT ) ≈ £263.19 | ≈ $345.58 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 10 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 830713 | ||||||||||
| Mfg Part No: | ATV12P037F1 | ||||||||||
| UPC/EAN: | 3606480071041 | ||||||||||
| Weight: | 0.907 kg | ||||||||||
| Type: | ATV12P037F1 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Schneider Electric ATV12P037F1:
| Complementary | |
| Discrete input number | 4 |
| Discrete output number | 2 |
| Analogue input number | 1 |
| Analogue output number | 1 |
| Relay output number | 1 |
| Physical interface | 2-wire RS 485 |
| Connector type | 1 RJ45 |
| Continuous output current | 2.4 A at 4 kHz |
| Method of access | Server Modbus serial |
| Speed drive output frequency | 0.5…400 Hz |
| Speed range | 1…20 |
| Sampling duration | 20 ms, tolerance +/- 1 ms for logic input; 10 ms for analogue input |
| Linearity error | +/- 0.3 % of maximum value for analogue input |
| Frequency resolution | Analog input: converter A/D, 10 bits; Display unit: 0.1 Hz |
| Time constant | 20 ms +/- 1 ms for reference change |
| Transmission rate | 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s |
| Transmission frame | RTU |
| Number of addresses | 1…247 |
| Data format | 8 bits, configurable odd, even or no parity |
| Communication service | Read holding registers (03) 29 words; Write single register (06) 29 words; Write multiple registers (16) 27 words; Read/write multiple registers (23) 4/4 words; Read device identification (43) |
| Type of polarization | No impedance |
| 4 quadrant operation possible | False |
| Asynchronous motor control profile | Quadratic voltage/frequency ratio; Voltage/frequency ratio (V/f); Sensorless flux vector control |
| Maximum output frequency | 4 kHz |
| Transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor |
| Acceleration and deceleration ramps | S; Linear from 0 to 999.9 s; U |
| Motor slip compensation | Adjustable; Preset in factory |
| Switching frequency | 2...16 kHz adjustable; 4...16 kHz with derating factor |
| Nominal switching frequency | 4 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | False |
| Line current | 11.4 A at 100 V (heavy duty); 9.3 A at 120 V (heavy duty) |
| Maximum input current | 9.3 A |
| Maximum output voltage | 240 V |
| Apparent power | 1.1 kVA at 240 V (heavy duty) |
| Maximum transient current | 3.6 A during 60 s (heavy duty); 4.0 A during 2 s (heavy duty) |
| Network frequency | 50...60 Hz |
| Relative symmetric network frequency tolerance | 5 % |
| Prospective line Isc | 1 kA |
| Base load current at high overload | 2.4 A |
| Power dissipation in W | Natural: 29.0 W |
| With safety function Safely Limited Speed (SLS) | False |
| With safety function Safe brake management (SBC/SBT) | False |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | False |
| With sft fct Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | False |
| With safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Protection type | Line supply overvoltage; Line supply undervoltage; Overcurrent between output phases and earth; Overheating protection; Short-circuit between motor phases; Against input phase loss in three-phase; Thermal motor protection via the drive by continuous calculation of I²t |
| Tightening torque | 0.8 N.m |
| Insulation | Electrical between power and control |
| Quantity per set | Set of 1 |
| Width | 72 mm |
| Height | 143 mm |
| Depth | 102.2 mm |
| Net weight | 0.7 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Environment | |
| Operating altitude | > 1000...2000 m with current derating 1 % per 100 m; |
| Operating position | Vertical +/- 10 degree |
| Product certifications | NOM; CSA; C-Tick; UL; GOST; RCM; KC |
| Marking | CE |
| Standards | UL 508C; UL 618000-5-1; IEC 61800-5-1; IEC 61800-3 |
| Assembly style | On base plate |
| Electromagnetic compatibility | Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Immunity to conducted disturbances level 3 conforming to IEC 61000-4-6; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Surge immunity test level 3 conforming to IEC 61000-4-5; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S2 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
| Overvoltage category | Class III |
| Regulation loop | Adjustable PID regulator |
| Electromagnetic emission | Radiated emissions environment 1 category C2 conforming to IEC 61800-3 2...16 kHz shielded motor cable; Conducted emissions with additional EMC filter environment 1 category C1 conforming to IEC 61800-3 4...12 kHz shielded motor cable |
| Vibration resistance | 1 gn (f = 13…200 Hz) conforming to IEC 60068-2-6; 1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn conforming to IEC 60068-2-27 for 11 ms |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3 |
| Noise level | 0 dB |
| Pollution degree | 2 |
| Ambient air transport temperature | -25…70 °C |
| Ambient air temperature for operation | -10…40 °C without derating; 40…60 °C with current derating 2.2 % per °C |
| Ambient air temperature for storage | -25…70 °C |
| Logistical informations | |
| Country of origin | ID |
| Main | |
| Range of product | Altivar 12 |
| Product or component type | Variable speed drive |
| Product specific application | Simple machine |
| Mounting mode | Cabinet mount |
| Communication port protocol | Modbus |
| Supply frequency | 50/60 Hz +/- 5 % |
| [Us] rated supply voltage | 100...120 V - 15...10 % |
| nominal output current | 2.4 A |
| Motor power kW | 0.37 kW |
| Motor power hp | 0.55 hp |
| EMC filter | Without EMC filter |
| IP degree of protection | IP20 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.500 cm |
| Package 1 Width | 18.500 cm |
| Package 1 Length | 19.500 cm |
| Package 1 Weight | 907.000 g |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 45 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 54.400 kg |
Questions & answers
What is the delivery time of Schneider Electric ATV12P037F1 frequency converter 0?
The article Schneider Electric ATV12P037F1 frequency converter 0 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 10 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric ATV12P037F1 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric ATV12P037F1 frequency converter 0 always at the best possible price. We can give you a discount of 2% on Schneider Electric ATV12P037F1 frequency converter 0 if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Schneider Electric ATV12P037F1 frequency converter 0 we can offer you a price of 307,37 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
Schneider Electric VW3A4416 EMC filter 1ph ATV12 up to 0.75 kW
This EMC input filter is an option for Altivar 12 series variable speed drives. This EMC filter allows your drive to meet electromagnetic compatibility requirements. The dimensions are 75 mm wide, 194 ...Lieske Part No.: 609773 Mfg Part No: VW3A4416 |
126,35 EUR 131,67 EUR
![]() ≈ £105.75 | ≈ $138.86
Made to order · Delivery time approx. 108 workdaysinfo_outline
|
Fitting accessory for Schneider Electric ATV12P037F1 frequency converter 0
|
Schneider Electric VW3A4551 Line reactor 10 mH 4 A VW3-A4551
This line choke is an option for variable speed drives of the Altivar range. Its nominal current is equal to 4A. It provides improved protection against overvoltages on the mains supply and helps ...Lieske Part No.: 148295 Mfg Part No: VW3A4551 |
215,65 EUR 224,73 EUR
![]() ≈ £180.50 | ≈ $237.00
Made to order · Delivery time approx. 48 workdaysinfo_outline
|
|
Schneider Electric LC1K1210B7 contactor 3-pole 1NO 5.5 kW 400 VAC3 12 A 24 V 50/60 Hz
The LC1K1210B7 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling electric drives and resistive loads. It is particularly used for motor control in industrial, ...Lieske Part No.: 293789 Mfg Part No: LC1K1210B7 |
-5% 53,28 EUR 56,17 EUR
![]() ≈ £44.60 | ≈ $58.55
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LC1K1210F7 contactor 3-pole 1NO 5.5 kW 400 VAC3 12 A 110 V 50/60 Hz
TeSys LC1K power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact, rated operating power at AC-3, 400 V 5.5 kW, rated operating current Ie at AC-3, 400 V 12 A, coil 110 V ...Lieske Part No.: 582132 Mfg Part No: LC1K1210F7 |
-5% 53,58 EUR 56,49 EUR
![]() ≈ £44.85 | ≈ $58.88
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LC1K1210E7 contactor 3-pole 1NO 5.5 kW 400 VAC3 12 A 48 V 50/60 Hz
TeSys LC1K power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact, rated operating power at AC-3, 400 V 5.5 kW, rated operating current Ie at AC-3, 400 V 12 A, coil 48 V ...Lieske Part No.: 583808 Mfg Part No: LC1K1210E7 |
-5% 55,82 EUR 58,86 EUR
![]() ≈ £46.72 | ≈ $61.35
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric VW3A9523 EMC connection plate up to 0.75 kW
This EMC compliance kit is part of the Altivar Machine ATV12 and ATV320 ranges, a range of variable speed drives for commercial equipment and simple machines. The metal plate ensures that the drive ...Lieske Part No.: 609308 Mfg Part No: VW3A9523 |
43,70 EUR 45,54 EUR
![]() ≈ £36.58 | ≈ $48.03
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LC1K1210V7 contactor 3-pole 1S 5.5 kW 400 VAC3 12 A 400 V 50/60 Hz
Leistungsschütz TeSys LC1K. 3 polig, 3 Schließer. Zusätzliche Hilfskontakte- 1 Schließer, Bemessungsbetriebsleistung bei AC-3, 400 V 5.5 kW, Bemessungsbetriebsstrom Ie bei AC-3, 400 V 12 A, Spule ...Lieske Part No.: 787897 Mfg Part No: LC1K1210V7 |
-5% 54,65 EUR 57,63 EUR
![]() ≈ £45.74 | ≈ $60.06
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LC1K1210P7 contactor 3-pole 1S 5.5kW 400VAC3 12A 230VAC
The LC1K1210P7 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor control and resistive loads. It has a rated ...Lieske Part No.: 835348 Mfg Part No: LC1K1210P7 |
-5% 53,28 EUR 56,17 EUR
![]() ≈ £44.60 | ≈ $58.55
Delivery time from supplier's stock (ca.) 5 workdaysinfo_outline
|
|
Schneider Electric GV2ME16 motor protection switch 3-pole 9-14 A push-button operation
Motor circuit breaker GV2 / GV3 A simple solution to control the motor during startup and to protect: - for motor feeders up to 4 kW / 4 V - for switching from continuous currents up to 8 A - Self ...Lieske Part No.: 878789 Mfg Part No: GV2ME16 |
-5% 105,45 EUR 110,83 EUR
![]() ≈ £88.26 | ≈ $115.89
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Schneider Electric LC1K1210FE7 power contactor 3-pole 1S 5
TeSys LC1K power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO contact, rated operating power at AC-3, 400 V 5.5 kW, rated operating current Ie at AC-3, 400 V 12 A, coil 115 V ...Lieske Part No.: 1773999 Mfg Part No: LC1K1210FE7 |
-5% 57,00 EUR 60,02 EUR
![]() ≈ £47.71 | ≈ $62.64
Made to order · Delivery time approx. 10 workdaysinfo_outline
|












