Schneider Electric APM6A0CTLN401 APM CONTROL UNIT ATV600 V2
|
-8% 2.349,45 EUR 2.541,50 EUR |
|
|
( 2.795,85 EUR incl. VAT ) ≈ £1,966.49 | ≈ $2,582.05 plus delivery charges: 100,00 € |
|
| Made to order · Delivery time approx. 8 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1866127 |
| Mfg Part No: | APM6A0CTLN401 |
| UPC/EAN: | 3606489873912 |
| Weight: | 7.745 kg |
| Type: | APM6A0CTLN401 |
Product information for Schneider Electric APM6A0CTLN401:
| Additional features | |
| [UH,nom] Rated operating voltage | 380 - 480 V |
| Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.012/50 Hz |
| Connection type | RJ45 (at decentralised graphical terminal) for Ethernet/Modbus TCP; RJ45 (at decentralised graphical terminal) for Modbus, serial |
| Physical interface | 2-wire RS 485 for Modbus, serial |
| Transmission frame | RTU for Modbus, serial |
| Transmission speed | 10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8; 9.6; 19.2; 38.4 kBit/s for Modbus, serial |
| Swap mode | Half-duplex, full-duplex, auto-negotiation Ethernet/Modbus TCP |
| Data format | 8 bits, configurable to odd, even, or no parity for Modbus, serial |
| Polarisation type | No impedance for Modbus, serial |
| Number of addresses | 1…247 for Modbus, serial |
| Access method | Slave Modbus TCP |
| Supply | External power supply for digital inputs: 24 V DC (19…30 V) |
| Local signalling | 3 LEDs for local diagnostics; 3 LEDs (two-colour) for status of integrated communication; 4 LEDs (two-colour) for status communication module |
| Width | 230 mm |
| Height | 678,3 mm |
| Depth | 108 mm |
| Product weight | 7,1 kg |
| Number of analog inputs | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0 - 10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0 - 20 mA / 4 - 20 mA, impedance: 250 Ohm, resolution 12 bits |
| Number of discrete inputs | 8 |
| Discrete input type | DI1...DI6 programmable, 24 V DC (= 30 V), impedance: 3.5 kOhm; DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (= 30 V); STOA, STOB Safe Torque Off (safely switched off torque), 24 V DC (= 30 V), impedance: > 2.2 kOhm |
| Input compatibility | DI1...DI6: Discrete input Level 1 PLC corresponds to IEC 61131-2; DI5, DI6: Discrete input Level 1 PLC corresponds to IEC 65A-68; STOA, STOB: Discrete input Level 1 PLC corresponds to IEC 61131-2 |
| Number of analogue outputs | 2 |
| Analog output type | Software-configurable voltage AO1, AO2: 0 - 10 V DC resistance 470 Ohm, resolution 10 bit; Software-configurable current AO1, AO2: 0 - 20 mA, resolution 10 bit |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI4) - digital input; 5 ms +/- 1 ms (DI5, DI6) - digital input; 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AO1) - analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 at temperature variation of 60 °C analog input; +/-1 % AO1, AO2 at temperature variation of 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AO1, AO2: +/- 0.2 % for analog output |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: Fault relay Normally open contact (NO)/Normally closed contact (NC) electrical life 100000 cycles; Configurable relay logic R2: Sequence relay no electrical life 100000 cycles; Configurable relay logic R3: Sequence relay no electrical life 100000 cycles |
| Update time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Min. switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Max. switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Insulation | between power and control terminals |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Main features | |
| Product series | Altivar Process Modular |
| Product or component type | Control module |
| Device short name | APM |
| Degree of protection (IP) | IP00 corresponds to IEC 61800-5-1; IP00 corresponds to IEC 60529 |
| Kit composition | Control unit; graphic terminal; Digi-Link cable; 24 V cable; cable for voltage measurement |
| Supply frequency | 50 - 60 Hz -5 - 5 % |
| Safety function | STO (Safe Torque Off) safely switched-off torque SIL 3 |
| Discrete input logic | 16 preset speeds |
| Communications protocol | Ethernet; Modbus, serial; Modbus TCP |
| Mounting | |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to ground |
| Noise level | 69 dB corresponds to 86/188/EEC |
| Power loss in W | Forced convection: 2390 W, switching frequency 2.5 kHz |
| Electromagnetic compatibility | Electrostatic discharge immunity test Level 3 according to IEC 61000-4-2; Immunity test against radiated high-frequency electromagnetic fields Level 3 according to IEC 61000-4-3; Electrical fast transient burst immunity test Level 4 according to IEC 61000-4-4; 1.2/50 μs - 8/20 μs surge immunity test Level 3 according to IEC 61000-4-5; Conducted radio-frequency electromagnetic field immunity test Level 3 according to IEC 61000-4-6 |
| Pollution degree | 2 corresponds to IEC 61800-5-1 |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) complies with IEC 60068-2-6; 0.5 gn (f= 13…200 Hz) complies with IEC 60068-2-6 |
| Shock resistance | 7 gn for 11 ms corresponds to IEC 60068-2-27 |
| Relative humidity | 5…95 % condensation not permitted corresponds to IEC 60068-2-3 |
| Operating ambient temperature | -10…40 °C (without power derating); 40…50 °C (with power derating factor) |
| Ambient temperature during storage | -40…70 °C |
| Operating altitude | = 1,000 m without power reduction; 1000 - 4800 m with current reduction 1 % per 100 m |
| Environmental properties | Chemical resistance Class 3C3 according to IEC 60721-3-3; Dust resistance Class 3S3 according to IEC 60721-3-3 |
| Standards | IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1 |
| Product certifications | TÜV |
| Text | CE |
| Packaging units | |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 17,8 cm |
| VPE 1 width | 28,7 cm |
| VPE 1 length | 73,5 cm |
| Packaging weight (Lbs) | 7,745 kg |
| VPE 2 type | S06 |
| VPE 2 quantity | 6 |
| VPE 2 height | 75 cm |
| VPE 2 width | 60 cm |
| VPE 2 length | 80 cm |
| VPE 2 weight | 61,9 kg |
Questions & answers
What is the delivery time of Schneider Electric APM6A0CTLN401 APM CONTROL UNIT ATV600 V2?
The article Schneider Electric APM6A0CTLN401 APM CONTROL UNIT ATV600 V2 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 8 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric APM6A0CTLN401 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric APM6A0CTLN401 APM CONTROL UNIT ATV600 V2 always at the best possible price. We can give you a discount of 2% on Schneider Electric APM6A0CTLN401 APM CONTROL UNIT ATV600 V2 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
Schneider Electric APM1A0C16N401 APM 160 kW 380–400 V V2
Standard power supply module, Altivar Process Modular, 110-160 kW, 380-480 V, IP00.Lieske Part No.: 1865826 Mfg Part No: APM1A0C16N401 |
-12% 14.559,00 EUR 16.575,81 EUR
![]() ≈ £12,185.88 | ≈ $16,000.34
Made to order · Delivery time approx. 8 workdaysinfo_outline
|
Fitting accessory for Schneider Electric APM6A0CTLN401 APM CONTROL UNIT ATV600 V2
|
Schneider Electric APM1A0C16N401 APM 160 kW 380–400 V V2
Standard power supply module, Altivar Process Modular, 110-160 kW, 380-480 V, IP00.Lieske Part No.: 1865826 Mfg Part No: APM1A0C16N401 |
-12% 14.559,00 EUR 16.575,81 EUR
![]() ≈ £12,185.88 | ≈ $16,000.34
Made to order · Delivery time approx. 8 workdaysinfo_outline
|
|
Schneider Electric APM1A0C16N4RH APM RH 160 kW 380...400 V
Standard power supply module, Altivar Process Modular, 110-160 kW, 380-480 V, IP00, reduced height.Lieske Part No.: 1866136 Mfg Part No: APM1A0C16N4RH |
-12% 10.340,80 EUR 11.773,13 EUR
![]() ≈ £8,655.25 | ≈ $11,364.54
Made to order · Delivery time approx. 8 workdaysinfo_outline
|
|
Schneider Electric VW3A97A01 APM Front Face Cover
Front cover for a standard power module - Altivar Process Modular.Lieske Part No.: 1869069 Mfg Part No: VW3A97A01 |
-15% 188,60 EUR 220,62 EUR
![]() ≈ £157.86 | ≈ $207.27
Made to order · Delivery time approx. 8 workdaysinfo_outline
|