Mitsubishi 262949 A8NPRT_2P Profinet 2-port interface card for FR-A/F800
|
238,45 EUR 248,49 EUR |
|||||||||||
|
( 283,76 EUR incl. VAT ) ≈ £199.58 | ≈ $262.06 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Lieske Part No.: | 1337040 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | 262949 | ||||||||||
| Weight: | 0.123 kg | ||||||||||
| Type: | A8NPRT_2P | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Mitsubishi 262949:
Applications
The A8NPRT_2P is designed for use in industrial automation systems, particularly in installations with frequency inverters from the FR-A and F800 series. It is used to enable communication between drive technology and higher-level control systems, for example in the manufacturing industry, packaging technology, or machine building. The support for Profinet enables fast, reliable, and deterministic data transmission, which is required for time-critical applications. The Drive Profile function simplifies the parameterization and control of the drive, as standardized data points and functions are used, which can be directly accessed by the control system.
Functions and Equipment in Detail
The interface card features two Profinet ports, enabling the frequency inverter to be integrated into a Profinet network. The card supports communication via the Profinet protocol, which is based on Ethernet and optimized for industrial applications. The Drive Profile function enables standardized communication with the drive, thereby simplifying integration into existing control systems. The card is designed for use in frequency inverters of the FR-A and F800 series and is directly installed into the device.
Technology Explained Simply
The A8NPRT_2P uses the Profinet protocol, which operates on the basis of Ethernet but is optimized for industrial requirements. It enables high data transfer rates and deterministic communication, which is necessary for real-time control of drives. The Drive Profile function is a standard that unifies communication between control and drive by providing defined data points and functions. This allows the control system to directly access drive functions without requiring special adaptations or individual programming. The card is designed for use in frequency inverters of the FR-A and F800 series and is integrated into the device.
Compatibility and Accessories
The interface card is specifically developed for Mitsubishi frequency inverters of the FR-A and F800 series. Compatibility is limited to these devices, as the card is directly installed into the frequency inverter. Use with other frequency inverters or control systems is not intended. The card supports Profinet network communication and is designed for use with Drive Profile functions.
Installation and Mounting
The A8NPRT_2P is directly installed into the frequency inverter of the FR-A or F800 series. Mounting is done by inserting the card into the designated slot in the frequency inverter. No additional mounting aids or tools are required. Installation is carried out according to the technical specifications of the frequency inverter, with electrical connections and network interfaces to be made according to the manufacturer’s instructions. The card is designed for use in industrial environments and does not require special mounting conditions.
Operational Advantages
Using the A8NPRT_2P enables simple and reliable integration of frequency inverters into Profinet-based automation systems. The Drive Profile function reduces the complexity of parameterization and control, as standardized data points are used. Communication via Profinet provides high data transfer rates and deterministic transmission, which is important for real-time drive control. The card is specifically developed for Mitsubishi frequency inverters FR-A and F800, ensuring optimal compatibility and reliability.
| General | |
| Manufacturer | Mitsubishi |
| Product type | Profinet 2port interface card |
| Compatibility | frequency inverter FR-A/F800 |
| Network protocol | Profinet |
| Number of ports | 2 |
| Function | Drive Profile |
Questions & answers
What is the delivery time of Mitsubishi 262949 A8NPRT_2P Profinet 2-port interface card for FR-A/F800 ?
The article Mitsubishi 262949 A8NPRT_2P Profinet 2-port interface card for FR-A/F800 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Mitsubishi 262949 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Mitsubishi 262949 A8NPRT_2P Profinet 2-port interface card for FR-A/F800 always at the best possible price. We can give you a discount of 2% on Mitsubishi 262949 A8NPRT_2P Profinet 2-port interface card for FR-A/F800 if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Mitsubishi 262949 A8NPRT_2P Profinet 2-port interface card for FR-A/F800 we can offer you a price of 234,87 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.



