LTC H07V-K 4.0 mm² green/yellow 100 m in foil PVC-insulated single-core cable Eca
|
122,76 EUR |
|||||||||||
|
incl. 43,82 EUR copper surcharge ( 146,08 EUR incl. VAT ) ≈ £102.63 | ≈ $135.65 plus delivery charges: 100,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| Sales unit: 100 meters | |||||||||||
| In Stock: >50 meters | |||||||||||
| Lieske Part No.: | 260681 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | |||||||||||
| Weight: | 5.616 kg | ||||||||||
| Type: | H07V-K 4,0 GNGE | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for LTC H07V-K 4,0 GNGE:
Applications
This cable is designed for use in electrical installations indoors, where a safe and durable connection is required. It is commonly used in residential and commercial buildings to connect electrical devices, lighting systems, and distributors. Installation takes place in closed systems to minimize mechanical and environmental influences. The cable is not intended for outdoor use or in damp rooms.
Functions and Features in Detail
The cable consists of a bare, fine-stranded copper conductor, ensuring high electrical conductivity and flexibility. Insulation is provided with PVC in accordance with VDE 0207, ensuring good mechanical stability and chemical resistance. The sheath color complies with VDE 0293 standards, enabling clear identification of the cable within the electrical system. The green/yellow color identifies the protective conductor function, which is required for grounding electrical devices and systems.
Technical Explanation
The rated voltage of 450/750 V defines the maximum voltage the cable can safely transmit. The test voltage of 2500 V is used for quality control and ensures that the insulation does not break down even under increased stress. The maximum operating temperature is +70 °C, and the cable can be installed at temperatures between +5 °C and +70 °C. After installation, the cable can operate at temperatures from -30 °C to +70 °C. The minimum bending radius is 15 times the cable diameter to prevent damage to the conductor. Flame retardancy according to VDE 0472 T. 804 test method B (equivalent to IEC 332-1) ensures that the cable does not ignite quickly in case of fire and limits flame spread.
Compatibility and Accessories
The cable is designed for use in standard installation systems and can be connected with common terminals, plug connectors, and other connection elements. It is suitable for use in electrical installations in accordance with applicable standards, especially in conjunction with control panels, distributors, and lighting systems. The use of green/yellow protective conductors is required by VDE 0100-510 to enable clear identification of the earthing connection.
Installation and Mounting
Installation takes place in closed systems such as conduits or channels to protect the cable from mechanical stress and environmental influences. Installation should occur at temperatures between +5 °C and +70 °C. After installation, the cable must be bent at least 15 times its diameter to avoid damaging the conductor. The cable is not intended for direct installation on open routes such as trays or gutters.
Operational Advantages
The PVC insulation provides high mechanical stability and chemical resistance, extending the cable’s service life. The fine-stranded copper structure ensures high flexibility, simplifying installation. Flame retardancy according to VDE 0472 T. 804 test method B increases safety in case of fire. The clear color coding according to VDE 0293 enables easy identification of the cable within the electrical system, particularly the protective conductor function in green/yellow.
The item price shown refers to 100 meters LTC H07V-K 4,0 GNGE
| General | |
| Nominal voltage | 450/750 V |
| Test voltage | 2500 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | according to VDE 0472 T. 804 test type B |
| Conductor | bare copper, fine-stranded |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | in accordance with VDE 0293 |
Questions & answers
What is the delivery time of LTC H07V-K 4.0 mm² green/yellow 100 m in foil PVC-insulated single-core cable Eca?
The article LTC H07V-K 4.0 mm² green/yellow 100 m in foil PVC-insulated single-core cable Eca is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of LTC H07V-K 4,0 GNGE to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you LTC H07V-K 4.0 mm² green/yellow 100 m in foil PVC-insulated single-core cable Eca always at the best possible price. We can give you a discount of 2% on LTC H07V-K 4.0 mm² green/yellow 100 m in foil PVC-insulated single-core cable Eca if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 6 meters of LTC H07V-K 4.0 mm² green/yellow 100 m in foil PVC-insulated single-core cable Eca we can offer you a price of 112,70 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
How many units does the article contain?
LTC H07V-K 4.0 mm² green/yellow 100 m in foil PVC-insulated single-core cable Eca is offered by us in a sales unit of 100 meters If you need a larger quantity, you can contact us at any time. We will make a special offer for you