LTC H05V-K 1.0 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton
|
39,38 EUR |
|||||||||||
|
incl. 11,07 EUR copper surcharge ( 46,86 EUR incl. VAT ) ≈ £32.92 | ≈ $43.51 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| Sales unit: 100 meters | |||||||||||
| In Stock: >100 meters | |||||||||||
| Lieske Part No.: | 323140 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | |||||||||||
| UPC/EAN: | 4013728030484 | ||||||||||
| Weight: | 1.431 kg | ||||||||||
| Type: | H05V-K 1,0 DBL RAL 5010 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for LTC H05V-K 1,0 DBL RAL 5010:
Applications
This cable is suitable for use in enclosed devices, in electrical installations in residential and commercial buildings, and in lighting technology. It is intended for indoor use, particularly in areas where installation takes place in conduits, pipes, or under plaster. Its use is restricted to doorbell and signaling systems, meaning it is not suitable for main power supply or high-power applications.
Functions and Features in Detail
The cable consists of a fine-stranded, bare copper conductor, ensuring high flexibility and good electrical conductivity. The PVC insulation provides reliable electrical protection and is specified according to VDE 0207. The dark blue (RAL 5010) outer sheath color allows for easy identification during installation and maintenance. The cable is rated for a nominal voltage of 300/500 V, which is sufficient for typical low-voltage applications in electrical installations.
Technical Explanation
The maximum operating temperature is +70 °C. During installation, the cable may be used at temperatures between +5 °C and +70 °C. After installation, it can be operated at temperatures from -30 °C to +70 °C. The minimum bending radius is 15 times the cable diameter, enabling flexible installation without compromising cable integrity. Flame retardancy corresponds to test method B according to VDE 0472 Part 804 (equivalent to IEC 332-1), meaning the cable does not propagate flames during a fire test and thus presents limited fire hazard.
Compatibility and Accessories
The cable is suitable for use in standard installation systems, particularly in conjunction with cable ducts, conduits, and other protective installations. It is compatible with standard terminals, plug connectors, and other connection components for low-voltage systems. The dark blue (RAL 5010) color supports color coding according to VDE 0293, which is helpful during installation and maintenance.
Installation and Mounting
The cable can be installed in protected installations, e.g., in conduits, pipes, or under plaster. Installation must take place at temperatures between +5 °C and +70 °C. After installation, the cable must be operated at temperatures between -30 °C and +70 °C. The minimum bending radius of 15 times the cable diameter must be observed to avoid cracks or breaks in the insulation material. The cable is not intended for outdoor use or in damp environments, as no specific protection rating such as IP67 is specified.
Operational Advantages
The H05V-K 1.0 DBL RAL 5010 offers high flexibility and electrical reliability. The PVC insulation ensures stable electrical protection, and flame retardancy according to VDE 0472 Part 804 test method B enhances safety in case of fire. The RAL 5010 color coding simplifies identification during installation and maintenance. The cable is optimized for use in doorbell and signaling systems, ensuring specific application safety.
The item price shown refers to 100 meters LTC H05V-K 1,0 DBL RAL 5010
| General | |
| Nominal voltage | 300/500 V |
| Test voltage | 2000 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | VDE 0472 T. 804 test type B (IEC 332-1) |
| Conductor | bare copper, fine-stranded |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | dark blue RAL 5010 |
Questions & answers
What is the delivery time of LTC H05V-K 1.0 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton?
The article LTC H05V-K 1.0 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of LTC H05V-K 1,0 DBL RAL 5010 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you LTC H05V-K 1.0 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton always at the best possible price. We can give you a discount of 2% on LTC H05V-K 1.0 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 meters of LTC H05V-K 1.0 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton we can offer you a price of 35,98 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
How many units does the article contain?
LTC H05V-K 1.0 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton is offered by us in a sales unit of 100 meters If you need a larger quantity, you can contact us at any time. We will make a special offer for you