Ifm Electronic TCC931 temperature transmitter Pt1000 PNP/NPN IO EL=100 160 bar clamp DN50 M12
|
555,80 EUR |
|
|
( 661,40 EUR incl. VAT ) ≈ £465.20 | ≈ $609.16 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 8 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 703922 |
| Mfg Part No: | TCC931 |
| UPC/EAN: | 4021179322393 |
| Weight: | 0.416 kg |
| Type: | TCC931 |
Product information for Ifm Electronic TCC931:
| Accuracy / Deviations | |
| Accuracy of analogue output | ± 0,2 K |
| IO-Link accuracy | ± 0,2 K |
| Temperature coefficient analogue output | < ± 0.02; (At deviation from reference condition 25 ± 5 °C) % of span / 10 K |
| Temperature coefficient IO-Link | < ± 0.01; (deviation from reference condition 25 ± 5 °C) % of span / 10 K |
| Approvals / tests | |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 35 g (10...2000 Hz) |
| MTTF | 329 years |
| Note on approval | Factory certificate available for download at www.factory-certificate.ifm |
| UL approval | Approval number UL / K021; File number UL / E217884 |
| Electrical connection | |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data | |
| Operating voltage | 18...32 DC; ("supply class 2" according to cULus) V |
| Electricity consumption | 10; (24 V) mA |
| Protection class | III |
| Standby delay time | 6 s |
| Reverse polarity protection | |
| Integrated watchdog | |
| Environmental conditions | |
| Ambient temperature | -25...70 °C |
| Note on ambient temperature | max. internal device temperature: 125 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 68; IP 69K |
| Field of application | |
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000 |
| Reference element | 1 x NTC |
| Media | Liquid and gaseous media |
| Compressive strength | 160 bar / 16 MPa |
| Minimum immersion depth | 15 mm |
| Interfaces | |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | BLOB / Binary Large Object transfer; Common - I&D / Identification and Diagnosis; Function / Measurement data, standard resolution |
| Required master port class | A |
| Analog process data | 1 |
| Process data binary | 1 |
| Min. process cycle time | 4,4 ms |
| IO-Link resolution temperature | 0,01 K |
| Supported DeviceIDs | Operating mode / DeviceID; default / 1129 |
| SIO mode | |
| Measurement / adjustment range | |
| Rod length L | 100 mm |
| Note on measurement range | scalable |
| Factory setting | -10...150 °C / 14...302 °F |
| Calibration check limit | 0,5...3 K |
| In steps of | 0,05 K |
| Analog output resolution | 0,05 K |
| Mechanical data | |
| Housing | Cylindrical |
| Dimensions | Ø 50 / L = 164,8 mm |
| Materials | 1.4404 (stainless steel / 316L); PEI; FKM; PFA |
| Materials in contact with the medium | 1.4404 (stainless steel / 316L); PEEK |
| Suitable for process connection standard | DIN 32676 Series A (DIN) / Clamp DN50; DIN 32676 Series B (ISO) / Clamp DN42.4, DN48.3; DIN 32676 Series C (ASME BPE) / Clamp 2"; ISO 2852 / Clamp DN40, DN51 |
| Surface roughness Ra/Rz of medium-contacting surfaces | Ra < 0,8 µm |
| Rod diameter | 6 mm |
| Outputs | |
| Total number of outputs | 2 |
| Output signal | Analog signal; IO-Link; (calibration check status) |
| Electrical version | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | Normally closed contact (NC); (Diagnostic signal) |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 100 mA |
| Diagnostic output | Calibration check status and fault diagnosis |
| Number of analogue outputs | 1 |
| Analog output current | 4...20 mA |
| Max. load | (Ub - 15 V) x 50 Ω |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features | |
| Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
| Measuring range | -25...160 °C / -13...320 °F |
| Communication interface | IO-Link |
| Process connection | Clamp DN50 (2") DIN 32676 (ISO 2852) |
| Installation length EL | 100 mm |
| Remarks | |
| Remarks | MS = set measurement range; supply voltage "supply class 2" according to cULus |
| Response times | |
| Response dynamics T05 / T09 | 1,5 / 4 s |
| Software / Programming | |
| Parameterization options | Display unit; scaling analog output; calibration check limit; switching logic diagnostic output; simulation mode |
Questions & answers
What is the delivery time of Ifm Electronic TCC931 temperature transmitter Pt1000 PNP/NPN IO EL=100 160 bar clamp DN50 M12?
The article Ifm Electronic TCC931 temperature transmitter Pt1000 PNP/NPN IO EL=100 160 bar clamp DN50 M12 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 8 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Ifm Electronic TCC931 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Ifm Electronic TCC931 temperature transmitter Pt1000 PNP/NPN IO EL=100 160 bar clamp DN50 M12 always at the best possible price. We can give you a discount of 2% on Ifm Electronic TCC931 temperature transmitter Pt1000 PNP/NPN IO EL=100 160 bar clamp DN50 M12 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.