Product information for Ifm Electronic PI1709:
| Accuracy / Deviations | |
| Switching point accuracy | < ± 0.2; (DIN EN IEC 62828-1; Turn down 1:1) % of span |
| Repeatability | < ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span |
| Characteristic deviation | < ± 0.2; (DIN IEC EN 62828-1 including zero point and span error, non-linearity, hysteresis; turn down 1:1) % of span |
| Linearity deviation | < ± 0.15; (turn down 1:1) % of span |
| Neutral point stabilisation | IO-Link, analogue output / 0.15; (See operating manual for zero point behaviour); Display, switching output / 0.2 % of range |
| Hysteresis deviation | < ± 0.15; (turn down 1:1) % of span |
| Long-term stability | < ± 0.1; (turn down 1:1; per year) % of span |
| Total deviation over temperature range | Temperature range / total deviation; -25...15 °C / characteristic deviation ± 0.05 % of span / 10 K; 15...80 °C / characteristic deviation; 80...150 °C / characteristic deviation ± 0.1 % of span / 10 K |
| Notes on accuracy / deviation | Further information see section Diagrams and curves. |
| Accuracy | ± 2.5+ (0.08 x (ambient temperature - medium temperature)) K |
| Resolution | 0,2 K |
| Approvals / tests | |
| EMC | DIN EN 61326-1 |
| Shock resistance | DIN EN 60068-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 20 g (10...2000 Hz) |
| MTTF | 214 years |
| UL approval | Approval number UL / J048; File number UL / E174189 |
| Displays / controls | |
| Indication | Display unit / LED, green; Switching state / LED, yellow; Function indicator / alphanumeric display, 4-digit; Measured values / alphanumeric display, 4-digit |
| Display unit | mbar; psi; kPa; inH2O |
| Electrical connection | |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data | |
| Minimum insulation resistance | 100; (500 V DC) MΩ |
| Protection class | III |
| Operating voltage | 20...30 DC V |
| Electricity consumption | 3,5...21,5 mA |
| Standby delay time | < 1 s |
| Reverse polarity protection | |
| Integrated watchdog | |
| Environmental conditions | |
| Ambient temperature | -25...80 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 67; IP 68; IP 69K |
| Field of application | |
| Special feature | Gold-plated contacts |
| Application | Flush-mounted for food and beverage industry |
| Media | Paste and solid-containing media; Liquid and gaseous media |
| Medium temperature | -25...150 °C |
| Min. bursting pressure | 30000 mbar / 435 psi / 3000 kPa |
| Compressive strength | 10000 mbar / 145 psi / 1000 kPa |
| Vacuum tightness | -1000 mbar / -0.1 MPa |
| Pressure type | Relative pressure; vacuum |
| MAWP for applications according to CRN | 10 bar |
| Backlash-free | |
| Interfaces | |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D / Identification and Diagnosis; Function / Measurement data, high resolution |
| Required master port class | A |
| Min. process cycle time | 5,6 ms |
| IO-Link pressure resolution | 0.1 mbar |
| IO-Link resolution temperature | 0,2 K |
| IO-Link process data (cyclic) | Function / bit length; pressure / 32; temperature / 32; device status / 4; binary switching information / 2 |
| IO-Link functions (asynchronous) | application-specific marking; internal temperature; operating hour counter; switching cycle counter; pressure peak counter; sensor cell diagnosis |
| Supported DeviceIDs | Operating mode / DeviceID; default / 1151 |
| SIO mode | |
| Measurement / adjustment range | |
| Switching point SP | -997...1000 mbar / -14.46...14.5 psi / -400...401 inH2O / -4.9...100 kPa |
| Reverse switch point rP | -1000...997 mbar / -14.5...14.46 psi / -401...400 inH2O / -100...99.7 kPa |
| Analog start point | -1000...599 mbar / -14.5...8.68 psi / -401...240 inH2O / -100...59.9 kPa |
| Analog endpoint | -599...1000 mbar / -8.68...14.5 psi / -240...401 inH2O / -59.9...100 kPa |
| Min. distance between SP and rP | 3 mbar / 0.05 psi / 2 inH2O / 0.3 kPa |
| In steps of | 1 mbar / 0.01 psi / 1 inH2O / 0.1 kPa |
| Factory setting | SP1 = -500 mbar / rP1 = -540 mbar; SP2 = 500 mbar / rP2 = 460 mbar; ASP = -1000 mbar / AEP = 1000 mbar; dAP = 2.00 s / dAA = 2.00 s |
| Mechanical data | |
| Housing | Cylindrical |
| Dimensions | Ø 50 / L = 107 mm |
| Materials | Housing: 1.4404 (stainless steel / 316L); buttons: PBT; seals: FKM; M12 connector: PEI; display: PFA; venting membrane: PTFE |
| Materials in contact with the medium | Measurement cell: ceramic (99.9 % Al2O3); Process connection: 1.4435 (stainless steel / 316L) surface finish: Ra < 0.4 µm / Rz = 4 µm; Sealing: PTFE |
| Min. pressure cycles | 100 million |
| Tightening moment | 35 Nm |
| Outputs | |
| Total number of outputs | 2 |
| Output signal | Switching signal; Analogue signal; IO-Link |
| Electrical version | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Number of analogue outputs | 1 |
| Analog output current | 4...20, reversible; (scalable) mA |
| Short-circuit protection type | timed |
| Max. load | 300 Ω |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 100 mA |
| Switching frequency DC | 125 Hz |
| Short-circuit protection | |
| Overload resistant | |
| Product features | |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range | -1...1 bar / -1000...1000 mbar / -14.5...14.5 psi / -401...401 inH2O / -100...100 kPa |
| Process connection | Threaded connection G 1 external thread with sealing contour Aseptoflex Vario |
| Note | G1 thread according to ISO 228. Alternatively, sealing via rear sealing contour with gasket in accordance with DIN EN ISO 1179-2. |
| Response times | |
| Process value damping dAP | 0...99,99 s |
| Attenuation analog output dAA | 0...99,99 s |
| Step response time analog output | 30 ms |
| Min. response time relay output dAP | 3 ms |
| Response dynamics T05 / T09 | < 45 / < 200; (DIN EN 60751 water ; > 0.9 m/s) s |
Questions & answers
What is the delivery time of Ifm Electronic PI1709 pressure sensor -1000...1000 mbar G 1 external Aseptoflex IO-Link rel. vacuum?
The article Ifm Electronic PI1709 pressure sensor -1000...1000 mbar G 1 external Aseptoflex IO-Link rel. vacuum is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 8 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Ifm Electronic PI1709 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Ifm Electronic PI1709 pressure sensor -1000...1000 mbar G 1 external Aseptoflex IO-Link rel. vacuum always at the best possible price. We can give you a discount of 2% on Ifm Electronic PI1709 pressure sensor -1000...1000 mbar G 1 external Aseptoflex IO-Link rel. vacuum if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.