Ifm Electronic PE2091 pressure sensor 0...250 bar G 1/4 internal IO-Link -25...80 °C relative pressure
|
490,10 EUR |
|
|
( 583,22 EUR incl. VAT ) ≈ £410.21 | ≈ $537.15 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 8 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 695272 |
| Mfg Part No: | PE2091 |
| UPC/EAN: | 4021179308441 |
| Weight: | 0.277 kg |
| Type: | PE2091 |
Product information for Ifm Electronic PE2091:
| Accuracy / Deviations | |
| Switching point accuracy | < ± 0.4; (turn down 1:1) % of span |
| Repeatability | < ± 0.1; (at temperature variations < 10 K; Turn down 1:1) % of span |
| Characteristic deviation | < ± 0.25 (BFSL) / < ± 0.5 (LS); (turn down 1:1; BFSL = Best Fit Straight Line (minimum setting); LS = endpoint setting) % of span |
| Hysteresis deviation | < ± 0.1; (Turn down 1:1) % of span |
| Long-term stability | < ± 0.05; (turn down 1:1; per 6 months) % of span |
| Temperature coefficient zero point | 0.2; (-25...80 °C) % of span / 10 K |
| Temperature coefficient range | 0.2; (-25...80 °C) % of span / 10 K |
| Notes on accuracy / deviation | Switching point accuracy, characteristic curve deviation under DNVGL: < ± 1% |
| Approvals / tests | |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 20 g (10...2000 Hz) |
| MTTF | 161 years |
| Printer directive | Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request |
| Displays / controls | |
| Indication | display unit / 3 x LED, green (bar, psi, MPa); switching state / 2 x LED, yellow; measured values / alphanumeric display, red / green 4-digit |
| Electrical connection | |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data | |
| Operating voltage | 18...30 DC; (according to SELV/PELV) V |
| Electricity consumption | < 35 mA |
| Minimum insulation resistance | 100; (500 V DC) MΩ |
| Protection class | III |
| Standby delay time | 0,3 s |
| Reverse polarity protection | |
| Integrated watchdog | |
| Environmental conditions | |
| Ambient temperature | -25...80 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 65; IP 67 |
| Field of application | |
| Special feature | Gold-plated contacts |
| Measuring element | Ceramic-capacitive pressure sensor cell |
| Application | for industrial use |
| Media | Liquid and gaseous media |
| Conditionally suitable for | Use in gaseous media at pressures > 25 bar only on request |
| Medium temperature | -25...80 °C |
| Min. bursting pressure | 1000 bar / 14500 psi / 100 MPa |
| Compressive strength | 500 bar / 7250 psi / 50 MPa |
| Vacuum tightness | -1000 mbar / -0.1 MPa |
| Pressure type | Gauge pressure |
| Interfaces | |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis |
| Required master port class | A |
| Analog process data | 1 |
| Process data binary | 2 |
| Min. process cycle time | 2,3 ms |
| Supported DeviceIDs | Operation mode / DeviceID; default / 460 |
| SIO mode | |
| Measurement / adjustment range | |
| Switching point SP | 1.5...250 bar / 25...3625 psi / 0.15...25 MPa |
| Reverse switch point rP | 0.5...249 bar / 10...3610 psi / 0.05...24.9 MPa |
| Analog start point | 0...200 bar / 0...2900 psi / 0...20 MPa |
| Analog endpoint | 50...250 bar / 725...3625 psi / 5...25 MPa |
| In steps of | 0.5 bar / 5 psi / 0.05 MPa |
| Mechanical data | |
| Housing | Cylindrical |
| Dimensions | Ø 34 / L = 90,7 mm |
| Materials | 1.4404 (stainless steel / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Materials in contact with the medium | 1.4404 (stainless steel / 316L); Al2O3 (ceramic); EPDM |
| Min. pressure cycles | 100 million |
| Tightening moment | 25...35; (recommended torque; dependent on lubrication, seal and pressure load) Nm |
| Choke element present | no (retrofit available) |
| Outputs | |
| Total number of outputs | 2 |
| Output signal | Switching signal; analog signal; IO-Link; (configurable) |
| Electrical version | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 250 mA |
| Switching frequency DC | < 500 Hz |
| Number of analogue outputs | 1 |
| Analog output current | 4...20; (scalable 1:5) mA |
| Max. load | 500 Ω |
| Analog output voltage | 0...10; (scalable 1:5) V |
| Minimum load resistance | 2000 Ω |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features | |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range | 0...250 bar / 0...3625 psi / 0...25 MPa |
| Process connection | threaded connection G 1/4 internal thread |
| Response times | |
| Response time | < 1,5 ms |
| Adjustable delay time dS, dr | 0...50 s |
| Process value damping dAP | 0...4 s |
| Attenuation analog output dAA | 0...4 s |
| Max. rise time analog output | 3 ms |
| Software / Programming | |
| Parameterization options | Hysteresis / window; normally open contact (NO) / normally closed contact (NC); switching / reset delay; damping; display unit; current / voltage output |
Questions & answers
What is the delivery time of Ifm Electronic PE2091 pressure sensor 0...250 bar G 1/4 internal IO-Link -25...80 °C relative pressure?
The article Ifm Electronic PE2091 pressure sensor 0...250 bar G 1/4 internal IO-Link -25...80 °C relative pressure is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 8 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Ifm Electronic PE2091 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Ifm Electronic PE2091 pressure sensor 0...250 bar G 1/4 internal IO-Link -25...80 °C relative pressure always at the best possible price. We can give you a discount of 2% on Ifm Electronic PE2091 pressure sensor 0...250 bar G 1/4 internal IO-Link -25...80 °C relative pressure if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.