Product information for Helukabel 23186:

Technical data:

Special silicone hose cable with increased heat resistance based on DIN VDE 0250 Part 1 and DIN VDE 0285-525-2-83/ DIN EN 50525-2-83
Temperature range -60°C to +180°C (briefly +220°C)
Limit temperature on the conductor during operation +180°C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Insulation resistance min. 200 MOhm x km
Current carrying capacity at ambient temperature up to +145°C according to DIN VDE 0100 for higher temperatures applies: 150°C - load capacity 100% 155°C - load capacity 91% 160°C - load capacity 82% 165°C - load capacity 71% 170°C - Load capacity 58% 175°C - Load capacity 41%
Minimum bending radius moving 10x cable Ø not moving 5x cable Ø
Coupling resistance max. 250 Ohm/km
Radiation resistance up to 20x106 cJ/kg (up to 20 Mrad)
Structure:
Tinned copper wire, according to DIN VDE 0295 cl.5, fine-stranded, BS 6360 cl.5, IEC 60228 cl.5
Core insulation made of silicone rubber
Core identification according to DIN VDE 0293-308 with white number print
Cores stranded in layers with optimal lay lengths
Inner sheath made of silicone rubber
Shielding braid made of tinned copper wires, coverage approx. 85%
Outer sheath made of silicone rubber
Sheath color: preferably red-brown with meter marking
Properties:
Resistant to high molecular oils, vegetable and animal fats, alcohols, plasticizers and clophenes, diluted acids, alkalis and salt solutions, oxidizing agents, tropical influences, sea water, oxygen, ozone.
If installed permanently, only install in open, ventilated pipe systems or ducts. Otherwise, the mechanical properties of silicone will be reduced if there is no air in connection with temperatures above 90°C.
Tests:
Halogen-free according to DIN VDE 0482 Part 267, DIN EN 50267-2-2, IEC 60754-2 (corresponds to DIN VDE 0472 Part 813)
Burning behavior no fire propagation according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1
Notes:
unshielded analogue type: SiHF
Use:
Silicone cables are used wherever cable insulation is exposed to high temperature fluctuations. Due to their excellent weather resistance, silicone cables can be used at both high and low temperatures down to -60°C. Particularly for use in power plants. Also in iron and steel works, rolling mills, foundries, aircraft construction and shipbuilding, as well as in cement, glass and ceramics factories, in headlights and high-performance lamps and heating devices of all kinds. The high shielding density ensures interference-free transmission of signals and pulses. The ideal interference-protected silicone hose cable for the above applications. EMC = Electromagnetic Compatibility To optimize the EMC properties, we recommend contacting the copper braid on both sides and over a large area all around.
Standard lengths: 500 m, 1000 m
Subject to technical changes.
Type: 23186


Please note...
For this article, we charge 14,85 EUR for measuring, cutting and re-furling the cable. If you take a whole 100m or 500m cable reel, the charge will of course be dropped.

The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.

Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
This article contains a copper surcharge of 2,93 EUR. This depends on daily copper prices and weight of included copper. You can inquire the copper price via phone under +49 7666 884990

Questions & answers

What is the delivery time of Helukabel 23186 HELU SiHF-C-Si 18G1,5qmm Red-brown Heat-resistant cable?

The article Helukabel 23186 HELU SiHF-C-Si 18G1,5qmm Red-brown Heat-resistant cable is currently not in stock und muss auftragsbezogen bestellt werden.

According to our experience the article is ready for dispatch within 8 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Helukabel 23186 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Helukabel 23186 HELU SiHF-C-Si 18G1,5qmm Red-brown Heat-resistant cable always at the best possible price. We can give you a discount of 2% on Helukabel 23186 HELU SiHF-C-Si 18G1,5qmm Red-brown Heat-resistant cable if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Helukabel 23186 - HELU SiHF Si 18G1 5qmm Red brown Heat resistant cable
Helukabel 23186 HELU SiHF-C-Si 18G1,5qmm Red-brown Heat-resistant cable
26,72 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Helukabel 23186 - HELU SiHF Si 18G1 5qmm Red brown Heat resistant cable
Name
Homepage
Street
ZIP-Code City
Telephone
Desired quantity
Comment
Data protection: The data entered here in the fields will be processed and stored electronically, according to GDPR Art. 6 par. 1b. It will only be used to answer your inquiry. Please look at our data protection policy for more infomation.
Name and email-address are the only required fields.