Product information for Hager NBN316:
Applications
The circuit breaker NBN316 is suitable for use in industrial and commercial electrical installations as well as in residential buildings where reliable protection of electrical circuits against overload and short circuit is required. It is particularly suitable for applications where high switching capacity and secure disconnection during network disturbances are necessary. The mounting width of 3 modules enables flexible installation in standard DIN rail systems, allowing easy integration into existing switchgear.
Functions and Equipment in Detail
The switch features a thermal tripping device for detecting overloads and an electromagnetic tripping device for rapid disconnection in case of short circuits. The tripping characteristic B ensures that the switch disconnects within seconds at current values between 3- and 5-times the rated current (i.e. 48 to 80 A), while higher current values trigger immediate disconnection. The labeling directly on the device allows for clear identification of the switching function, simplifying maintenance and servicing. The DIN rail quick mounting facilitates installation and reduces installation time.
Technology Explained Simply
The rated switching capacity is crucial for the reliability of the switch under load. According to EN 60898, the switching capacity Icn at 400 V is 10 kA, describing the switch's ability to safely disconnect a short-circuit current up to 10,000 A. According to IEC 60947-2, the ultimate switching capacity Icu at 400 V is 15 kA, representing the maximum switching capacity during a short circuit. The energy limitation class 3 means that the switch limits a certain amount of energy (I²t) during a short circuit, reducing the thermal stress on the installation. The pollution degree 2 indicates that the switch is suitable for environments where only minor pollution by solid dust or damp air occurs.
Compatibility and Accessories
The switch is suitable for mounting additional devices such as signaling contacts (e.g. MZ202), auxiliary contacts (e.g. MZ201), or locking devices (e.g. MZN175). These can be used to extend functions such as status indication or remote control. Compatible phase bar models such as KDN380A or KDN363A enable safe and orderly installation in switchgear. The connection terminals are designed for single-core conductors up to 35 mm² and multi-core conductors up to 25 mm², with a nominal torque of 2.80 Nm for both terminals. The mounting depth of 70 mm is suitable for installation in standard distribution boards.
Mounting and Installation
Mounting is done via a DIN rail quick mounting, enabling fast and secure attachment to standard DIN rails. The connection terminals are screw-type and allow 360° orientation, ensuring flexible cabling. The upper and lower terminals are designed for modular devices, enabling easy integration into existing switchgear. The mounting depth of 70 mm and dimensions of 83 mm height and 52.5 mm width fit standard distribution boxes.
Advantages in Operation
The switch offers high reliability in protecting electrical circuits. The combination of thermal and electromagnetic tripping devices ensures precise response to different fault conditions. The high switching capacity of 10 kA (IEC 60898) and 15 kA (IEC 60947-2) enables use in installations with high short-circuit currents. The possibility to add accessories later increases the flexibility and adaptability of the installation. RoHS compliance ensures environmentally friendly manufacturing and disposal.
| General | |
| Release characteristic | B |
| Number of poles (total) | 3 |
| Number of protected poles | 3 |
| Rated current | 16 A |
| Rated voltage | 400 V |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6 kV |
| Rated short-circuit breaking capacity Icn EN 60898 at 230 V | 10 kA |
| Rated short-circuit breaking capacity Icn EN 60898 at 400 V | 10 kA |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V | 30 kA |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V | 15 kA |
| Voltage type | AC |
| Frequency | 60 Hz |
| Current limiting class | 3 |
| Over voltage category | 3 |
| Pollution degree | 2 |
| Width in number of modular spacings | 3 |
| Built-in depth | 70 mm |
| Degree of protection (IP) | IP20 |
| Ambient temperature during operating | 70 °C |
| Connectable conductor cross section multi-wired | 25 mm² |
| Connectable conductor cross section solid-core | 35 mm² |
| Power loss | 8.27 W |
| Concurrently switching N-neutral | |
| Additional equipment possible | |
| Explosion-proof | |
| Flush-mounted installation | |
Questions & answers
What is the delivery time of Hager NBN316 LS switch 3P 10kA B-16A 3M?
The article Hager NBN316 LS switch 3P 10kA B-16A 3M is currently in stock
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Hager NBN316 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Hager NBN316 LS switch 3P 10kA B-16A 3M always at the best possible price. We can give you a discount of 2% on Hager NBN316 LS switch 3P 10kA B-16A 3M if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Hager NBN316 LS switch 3P 10kA B-16A 3M we can offer you a price of 119,36 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Hager NBN316 LS switch 3P 10kA B-16A 3M
|
Hager LZ060 spacing piece for heat dissipation
The LZ060 spacing piece from Hager is a specially developed component for heat dissipation in installation switchboxes and modular devices. It serves as a thermal spacer between electrical components ...Lieske Part No.: 178169 Mfg Part No: LZ060 |
3,37 EUR
![]() ≈ £2.82 | ≈ $3.70
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager KDN380A phase busbar 3P fork 16 mm² 80 A 12 M
The KDN380A phase bar from Hager is a 3-pole connecting element for installation in distributors and enclosures. It enables safe and structured 3-pole wiring of modular devices, particularly circuit ...Lieske Part No.: 278979 Mfg Part No: KDN380A |
20,61 EUR
![]() ≈ £17.25 | ≈ $22.65
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager MZ202 signal contact 1NO+1NC 6A 240V
Signal contact for MCB RCBO 125A 1 NO and 1 NC 6A 240VLieske Part No.: 502785 Mfg Part No: MZ202 |
46,55 EUR
![]() ≈ £38.96 | ≈ $51.16
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Hager KDN363A phase busbar 3P fork 10 mm² 63 A 12M
The Hager phase bar KDN363A is a 3-pole, modular distribution component for installation in switchgear and distribution boxes. It serves structured energy distribution and enables safe and efficient ...Lieske Part No.: 527757 Mfg Part No: KDN363A |
15,48 EUR
![]() ≈ £12.96 | ≈ $17.01
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager MZ201 auxiliary contact 1NO+1NC 6A 240V for MCB, RCBO, RCCB
Auxiliary contact for MCB RCBO 125A 1 NO and 1 NC 6A 240VLieske Part No.: 547425 Mfg Part No: MZ201 |
31,92 EUR
![]() ≈ £26.72 | ≈ $35.08
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager MZN175 locking device for LS, FI, FI-LS 1
Locking device for circuit breakers FI-switch FI-LS-switchLieske Part No.: 565350 Mfg Part No: MZN175 |
8,46 EUR
![]() ≈ £7.08 | ≈ $9.30
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager KZN023 end caps for phase busbar 2-pole and 3-pole
The KZN023 end cap from Hager is a shock protection cover end piece for phase bars, specifically designed for 2- and 3-pole systems. It serves as a protective cap for open ends of phase bars and ...Lieske Part No.: 580843 Mfg Part No: KZN023 |
10,07 EUR
![]() ≈ £8.43 | ≈ $11.07
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Hager KDN380B phase busbar 3P fork 16 mm² 80 A 57M
Compact busbars through the installation-friendly quick-connect terminal and bi-connect terminal is the terminal phase of the rail and the inflow and outflow performance problems. 3-pole miniature ...Lieske Part No.: 804339 Mfg Part No: KDN380B |
84,17 EUR
![]() ≈ £70.45 | ≈ $92.50
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager KDN363B phase busbar 3P fork 10 mm² 63 A 57M
Compact busbars through the installation-friendly quick-connect terminal and bi-connect terminal is the terminal phase of the rail and the inflow and outflow performance problems. 3-pole miniature ...Lieske Part No.: 829362 Mfg Part No: KDN363B |
67,36 EUR
![]() ≈ £56.38 | ≈ $74.03
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|