Frequency converter, soft starter from Moeller
You have been filtering for Moeller and therefore you see now only Frequency converter, soft starter from Moeller displayed.
You can choose other manufacturers on the left side in the menu or get the complete overview.
Frequency converter, soft starter from Moeller
|
Moeller 100415 EATON MSC-D-16-M15 (24VDC), DOL
Direct starter, basic device: MSC, Note: Not suitable for motors of efficiency class IE3., Motor data rated operating power AC-3 380 V 400 V 415 V: P= 7.5 kW, Setting range overload release: Ir= 10 - ...Lieske Part No.: 972197 Mfg Part No: 100415 Type: MSC-D-16-M15(24VDC) |
291,29 EUR
![]() ≈ £248.47 | ≈ $332.36
Delivery time on requestinfo_outline
|
|
Moeller 101046 EATON MSC-D-12-M17 (230V50Hz), DOL
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 5.5 kW, Setting range overload release: Ir= 8 - ...Lieske Part No.: 321296 Mfg Part No: 101046 Type: MSC-D-12-M17(230V50H |
261,74 EUR
![]() ≈ £223.26 | ≈ $298.65
Delivery time on requestinfo_outline
|
|
Moeller 101048 EATON MSC-D-12-M17 (24VDC), DOL
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 5.5 kW, Setting range overload release: Ir= 8 - ...Lieske Part No.: 793728 Mfg Part No: 101048 Type: MSC-D-12-M17(24VDC) |
341,36 EUR
![]() ≈ £291.18 | ≈ $389.49
Delivery time on requestinfo_outline
|
|
Moeller 102739 EATON MSC-D-0.63-M7(230V50Hz)/BBA direct starter to SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 0.12, 0.18 kW, Setting range overload release: ...Lieske Part No.: 340780 Mfg Part No: 102739 Type: MSC-D-0,63-M7(230V50 |
239,22 EUR
![]() ≈ £204.05 | ≈ $272.95
Delivery time on requestinfo_outline
|
|
Moeller 102950 EATON MSC-D-1-M7 (230V50Hz) / BBA, direct starter on SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 0.25 kW, Setting range overload release: Ir= 0.63 ...Lieske Part No.: 238385 Mfg Part No: 102950 Type: MSC-D-1-M7(230V50HZ) |
243,35 EUR
![]() ≈ £207.58 | ≈ $277.66
Delivery time on requestinfo_outline
|
|
Moeller 102951 EATON MSC-D-1.6-M7(230V50Hz)/BBA direct starter to SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 0.37, 0.55 kW, Overload release setting range: ...Lieske Part No.: 695226 Mfg Part No: 102951 Type: MSC-D-1,6-M7(230V50H |
247,48 EUR
![]() ≈ £211.10 | ≈ $282.37
Delivery time on requestinfo_outline
|
|
Moeller 102952 EATON MSC-D-2 ,5-M7 (230V50Hz) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 0.75 kW, Setting range overload release: Ir= 1.6 ...Lieske Part No.: 168161 Mfg Part No: 102952 Type: MSC-D-2,5-M7(230V50H |
251,33 EUR
![]() ≈ £214.38 | ≈ $286.77
Delivery time on requestinfo_outline
|
|
Moeller 102953 EATON MSC-D-4-M7 (230V50Hz) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 1.1, 1.5 kW, Setting range overload release: Ir= ...Lieske Part No.: 572735 Mfg Part No: 102953 Type: MSC-D-4-M7(230V50HZ) |
251,33 EUR
![]() ≈ £214.38 | ≈ $286.77
Delivery time on requestinfo_outline
|
|
Moeller 102954 EATON MSC-D-6.3-M7(230V50Hz)/BBA direct starter to SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 2.2 kW, Setting range overload release: Ir= 4 - 6.Lieske Part No.: 695077 Mfg Part No: 102954 Type: MSC-D-6,3-M7(230V50H |
251,95 EUR
![]() ≈ £214.91 | ≈ $287.47
Delivery time on requestinfo_outline
|
|
Moeller 102955 EATON MSC-D-10-M7 (230V50Hz) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 3 kW, Setting range overload release: Ir= 6.3 - ...Lieske Part No.: 807735 Mfg Part No: 102955 Type: MSC-D-10-M7(230V50HZ |
263,30 EUR
![]() ≈ £224.59 | ≈ $300.43
Delivery time on requestinfo_outline
|
|
Moeller 102956 EATON MSC-D-10-M9 (230V50Hz) / BBA, direct starter on SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 4 kW, Setting range overload release: Ir= 6.3 - ...Lieske Part No.: 238362 Mfg Part No: 102956 Type: MSC-D-10-M9(230V50HZ |
272,64 EUR
![]() ≈ £232.56 | ≈ $311.08
Delivery time on requestinfo_outline
|
|
Moeller 102957 EATON MSC-D-12-M12(230V50Hz)/BBA direct starter to SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 5.5 kW, Setting range overload release: Ir= 8 - ...Lieske Part No.: 407274 Mfg Part No: 102957 Type: MSC-D-12-M12(230V50H |
282,68 EUR
![]() ≈ £241.13 | ≈ $322.54
Delivery time on requestinfo_outline
|
|
Moeller 102963 EATON MSC-D-32-M32 (230V50Hz) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 15 kW, Setting range overload release: Ir= 25 - ...Lieske Part No.: 953010 Mfg Part No: 102963 Type: MSC-D-32-M32(230V50H |
500,12 EUR
![]() ≈ £426.60 | ≈ $570.64
Delivery time on requestinfo_outline
|
|
Moeller 102965 EATON MSC-D-0.4-M7(24VDC)/BBA direct starter to SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 0.09 kW, Setting range overload release: Ir= 0.25 ...Lieske Part No.: 384535 Mfg Part No: 102965 Type: MSC-D-0,4-M7(24VDC)/ |
244,38 EUR
![]() ≈ £208.46 | ≈ $278.84
Delivery time on requestinfo_outline
|
|
Moeller 102969 EATON MSC-D-2 ,5-M7 (24VDC) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 0.75 kW, Setting range overload release: Ir= 1.6 ...Lieske Part No.: 802742 Mfg Part No: 102969 Type: MSC-D-2,5-M7(24VDC)/ |
260,27 EUR
![]() ≈ £222.01 | ≈ $296.97
Delivery time on requestinfo_outline
|
|
Moeller 102970 EATON MSC-D-4-M7(24VDC)/BBA direct starter to SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 1.1, 1.5 kW, Setting range overload release: Ir= ...Lieske Part No.: 611420 Mfg Part No: 102970 Type: MSC-D-4-M7(24VDC)/BB |
260,27 EUR
![]() ≈ £222.01 | ≈ $296.97
Delivery time on requestinfo_outline
|
|
Moeller 102972 EATON MSC-D-10-M7 (24VDC) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 3 kW, Setting range overload release: Ir= 6.3 - ...Lieske Part No.: 835873 Mfg Part No: 102972 Type: MSC-D-10-M7(24VDC)/B |
276,64 EUR
![]() ≈ £235.97 | ≈ $315.65
Delivery time on requestinfo_outline
|
|
Moeller 102974 EATON MSC-D-12-M12 (24VDC) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 5.5 kW, Setting range overload release: Ir= 8 - ...Lieske Part No.: 558914 Mfg Part No: 102974 Type: MSC-D-12-M12(24VDC)/ |
295,76 EUR
![]() ≈ £252.28 | ≈ $337.46
Delivery time on requestinfo_outline
|
|
Moeller 102975 EATON MSC-D-16-M15 (24VDC) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Not suitable for motors of efficiency class IE3., Motor data rated operating power AC-3 380 V 400 V 415 V: P= 7.5 kW, setting range overload release: Ir= 10 - ...Lieske Part No.: 886630 Mfg Part No: 102975 Type: MSC-D-16-M15(24VDC)/ |
354,61 EUR
![]() ≈ £302.48 | ≈ $404.61
Delivery time on requestinfo_outline
|
|
Moeller 102976 EATON MSC-D-10-M17 (24VDC) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 3.4 kW, Setting range overload release: Ir= 6.3 - ...Lieske Part No.: 534359 Mfg Part No: 102976 Type: MSC-D-10-M17(24VDC)/ |
415,22 EUR
![]() ≈ £354.18 | ≈ $473.77
Delivery time on requestinfo_outline
|
|
Moeller 102978 EATON MSC-D-16-M17(24VDC)/BBA direct starter to SS adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 7.5 kW, Setting range overload release: Ir= 10 - ...Lieske Part No.: 652936 Mfg Part No: 102978 Type: MSC-D-16-M17(24VDC)/ |
418,32 EUR
![]() ≈ £356.83 | ≈ $477.30
Delivery time on requestinfo_outline
|
|
Moeller 102979 EATON MSC-D-25-M25 (24VDC) / BBA direct starter on SS Adapter
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 11 kW, Setting range overload release: Ir= 20 - ...Lieske Part No.: 946703 Mfg Part No: 102979 Type: MSC-D-25-M25(24VDC)/ |
484,72 EUR
![]() ≈ £413.47 | ≈ $553.07
Delivery time on requestinfo_outline
|
|
Moeller 102980 EATON MSC-D-32-M32 (24VDC) / BBA, direct starter on SS adapter 102 980
Direct starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 15 kW, Setting range overload release: Ir= 25 - ...Lieske Part No.: 318248 Mfg Part No: 102980 Type: MSC-D-32-M32(24VDC)/ |
609,87 EUR
![]() ≈ £520.22 | ≈ $695.86
Delivery time on requestinfo_outline
|
|
Moeller 102986 EATON MSC-R-2 ,5-M7 (230V50Hz) / BBA, reversing starter on SS Adapter
Reversing starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3, Motor data rated operating power AC-3 380 V 400 V 415 V: P= 0.75 kW, Setting range overload release: Ir= 1.Lieske Part No.: 501921 Mfg Part No: 102986 Type: MSC-R-2,5-M7(230V50H |
379,79 EUR
![]() ≈ £323.96 | ≈ $433.34
Delivery time on requestinfo_outline
|
Further Information: Frequenzumformer, Sanftanlasser
In the Frequenzumformer, Sanftanlasser section, Industry-Electronics offers a curated range of industrial components for professional use. Leading manufacturers such as Siemens, Schneider-Electric, Eaton ensure quality to current IEC and EN standards. This category belongs to the Automatisierungstechnik section of the Industrial Material range at Industry-Electronics.
For a complete overview of the Industrial Material range, visit Industrial Material. Our specialist team is available for volume enquiries, project advice and standards queries: +49 (0)7666 / 88499-0, sales@industry-electronics.com.
Typical Applications
| ✓ Manufacturing Automation & Robotics | ✓ Process Control & SCADA |
| ✓ Mechanical Engineering & Special-Purpose Machines | ✓ Power & Utility Technology |
| ✓ Food & Pharmaceutical Industry | ✓ Intralogistics & Conveyor Technology |
Why Industry-Electronics for Industrial Material?
▶ Leading Brands Siemens, Schneider Electric, Phoenix Contact, Weidmüller, WAGO, Eaton, ABB and Beckhoff – all from one source. | ▶ Complete B2B Range From PLC systems and switchgear to safety relays and industrial connectors. | ▶ B2B Expert Advice Our team advises on sizing, standards compliance and system integration – from component selection to project planning. |
▶ Volume Pricing & Framework Agreements Quantity tiers, project pricing and individual framework agreements for industrial customers and system integrators. | ▶ Fast Delivery Most items available from stock; express delivery available on request. | ▶ Standards-Compliant Quality All products meet applicable EN, IEC and VDE standards and Machinery Directive requirements. |