DEHN 943341 DG MD TT ACI 275 FM surge arrester Type 2
|
324,75 EUR |
|
|
( 386,45 EUR incl. VAT ) ≈ £271.82 | ≈ $356.90 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1198791 |
| Mfg Part No: | 943341 |
| UPC/EAN: | 4013364477179 |
| Weight: | 0.25 kg |
| Type: | DG MD TT ACI 275 FM |
| General | |
| SPD according to EN 61643-11 / IEC 61643-11 | Type 2 / class II |
| Energy coordination with terminal equipment (≤ 10 m) | Type 2 + type 3 |
| Nominal voltage (a.c.) (UN) | 230 / 400 V (50 / 60 Hz) |
| Max. continuous operating voltage (a.c.) [L-N] (UC) | 275 V (50 / 60 Hz) |
| Max. continuous operating voltage (a.c.) [N-PE] (UC) | 255 V (50 / 60 Hz) |
| Nominal discharge current (8/20 µs) [L-N] (In) | 20 kA |
| Nominal discharge current (8/20 µs) [N-PE] (In) | 80 kA |
| Max. discharge current (8/20 µs) [L-N] (Imax) | 40 kA |
| Max. discharge current (8/20 µs) [N-PE] (Imax) | 120 kA |
| Nominal load current for “V-connection” (IL) | 63 A |
| Voltage protection level [L-N]/[N-PE] (UP) | ≤ 1.5 / ≤ 1.5 kV |
| Voltage protection level [L-N]/[N-PE] at 5 kA (UP) | ≤ 1,5 / ≤ 1,5 kV |
| Follow current extinguishing capability [N-PE] (Ifi) | 100 Aeff |
| Response time [L-N] (tA) | ≤ 100 ns |
| Response time [N-PE] (tA) | ≤ 100 ns |
| Short-circuit withstand capability (ISCCR) | 25 kArms |
| Max. mains-side overcurrent protection with “V-connection” | 63 A gG |
| Max. mains-side overcurrent protection with stub wiring | none |
| Temporary overvoltage (TOV) [L-N] (UT) – Characteristic | 335 V / 5 sec. – withstand, 440 V / 120 min. – withstand |
| Temporary overvoltage (TOV) [N-PE] (UT) - Characteristic | 1200 V / 200 ms – withstand |
| Leakage current | no leakage current |
| Operating temperature range (TU) | -40 °C ... +80 °C |
| Operating state / fault indication | green / red |
| Number of ports | 1 |
| Cross-sectional area (min.) | 1.5 mm2 solid / flexible |
| Cross-sectional area (max.) with stub wiring | 35 mm2 stranded / 25 mm2 flexible |
| Cross-sectional area (max.) with “V-connection” | 16 mm2 Stranded / flexible |
| For mounting on | 35 mm DIN rails acc. to EN 60715 |
| Enclosure material | Thermoplastic, red, UL 94 V-0 |
| Place of installation | Indoor |
| Degree of protection | IP 20 |
| Capacity | 4 modules, DIN 43880 Standard DIN module, DIN 43880 |
| Type of remote signalling contact | changeover contact |
| Switching capacity (a.c.) | 250 V / 0.5 A |
| Switching capacity (d.c.) | 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
| Cross-sectional area for remote signalling terminals | max. 1.5 mm2 solid / flexible |
| Additional external fuse necessary | |
Questions & answers
What is the delivery time of DEHN 943341 DG MD TT ACI 275 FM surge arrester Type 2?
The article DEHN 943341 DG MD TT ACI 275 FM surge arrester Type 2 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of DEHN 943341 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you DEHN 943341 DG MD TT ACI 275 FM surge arrester Type 2 always at the best possible price. We can give you a discount of 2% on DEHN 943341 DG MD TT ACI 275 FM surge arrester Type 2 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.