DEHN 942115 DG MP TT 2P 275 FM surge protector Type 2+3
|
121,46 EUR |
|
|
( 144,54 EUR incl. VAT ) ≈ £101.66 | ≈ $133.48 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 861910 |
| Mfg Part No: | 942115 |
| UPC/EAN: | 4013364495333 |
| Weight: | 0.227 kg |
| Type: | DG MP TT 2P 275 FM |
| Technical data | |
| SPD according to EN 61643-11 / IEC 61643-11 | Type 2 + Type 3 / class II + class III |
| Energy coordination with terminal equipment (≤ 10 m) | type 2 + type 3 |
| Nominal voltage (a.c.) (UN) | 230 V (50 / 60 Hz) |
| Max. continuous operating voltage (a.c.) [L-N] (UC) | 275 V (50 / 60 Hz) |
| Max. continuous operating voltage (a.c.) [N-PE] (UC) | 255 V (50 / 60 Hz) |
| Nominal discharge current (8/20 µs) (In) | 20 kA |
| Max. discharge current (8/20 µs) (Imax) | 40 kA |
| Combination wave [L-N] (UOC) | 20 kV |
| Combination wave [N-PE] (UOC) | 6 kV |
| Nominal load current for “V-connection” (IL) | 40 A |
| Voltage protection level [L-N]/[N-PE] (UP) | ≤ 1.5 / ≤ 1.5 kV |
| Voltage protection level [L-N]/[N-PE] at 5 kA (UP) | ≤ 1 / ≤ 1.5 kV |
| Protective conductor current (IPE) | ≤ 10 µA |
| Response time [L-N] (tA) | ≤ 25 ns |
| Response time [N-PE] (tA) | ≤ 100 ns |
| Max. mains-side overcurrent protection | 125 A gG |
| Max. mains-side overcurrent protection with “V-connection” | 40 A gG |
| Max. mains-side overcurrent protection with stub wiring (double connection 2 x 10 mm²) | 125 A gG |
| Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR) | 50 kArms |
| Temporary overvoltage (TOV) [L-N] (UT) – Characteristic | 335 V / 5 sec. – Festigkeit, 440 V / 120 min. – sicherer Ausfall |
| Temporary overvoltage (TOV) [N-PE] (UT) - Characteristic | 1200 V / 200 ms – withstand |
| Operating temperature range (TU) | -40 °C ... +80 °C |
| Operating state / fault indication | green / red |
| Number of ports | 1 |
| Cross-sectional area (min.) | 1,5 mm2 eindrähtig, 6 mm2 feindrähtig |
| Cross-sectional area (max.) | 10 mm2 solid / fine stranded |
| Cross-sectional area (min.) with wire end ferrule | 1.5 mm² |
| Cross-sectional area (max.) with wire end ferrule | 6 mm² |
| Cross-sectional area (max.) with wire end ferrule without collar | 10 mm² |
| For mounting on | 35 mm DIN rails acc. to EN 60715 |
| Enclosure material | thermoplastic, red, UL 94 V-0 |
| Place of installation | indoor installation |
| Degree of protection | IP 20 |
| Capacity | 2 Standard DIN module, DIN 43880 |
| Approvals | DEKRA, VDE |
| Type of remote signalling contact | changeover contact |
| Switching capacity (a.c.) | 250 V / 0.5 A |
| Switching capacity (d.c.) | 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
| Cross-sectional area for remote signalling terminals | max. 1.5 mm2 solid / fine stranded |
Questions & answers
What is the delivery time of DEHN 942115 DG MP TT 2P 275 FM surge protector Type 2+3?
The article DEHN 942115 DG MP TT 2P 275 FM surge protector Type 2+3 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of DEHN 942115 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you DEHN 942115 DG MP TT 2P 275 FM surge protector Type 2+3 always at the best possible price. We can give you a discount of 2% on DEHN 942115 DG MP TT 2P 275 FM surge protector Type 2+3 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.