DEHN 907421
This image may differ from the desired article.
DEHN 907421DEHN 907421DEHN 907421
48,55 EUR 49,10 EUR
( 57,77 EUR incl. VAT )
≈ £40.64  |  ≈ $53.36
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 20 workdaysinfo_outline
1x Surge arrester 907421 Dehnrapid LSA protection class DRL RE 12
Datasheet:file_download Download
Lieske Part No.:517450
Mfg Part No: 907421
UPC/EAN: 4013364107618
Weight:0.0005 kg
Type:DRL RE 12
Graduated prices net
From piecesPrice per pieces
1045,64 EUR
2542,72 EUR
5039,81 EUR
7536,90 EUR

Product information for DEHN 907421:

The DEHN surge protection plug type DRL RE 12 (manufacturer's number 907421) is a single-stage end device protection, specifically designed for use in signal circuits with common reference potential. It serves as a protection plug with a let-through current of 12 kA and is energetically coordinated with DRL plug magazines. The installation is exclusively in disconnectors or DRL plug magazines, with grounding via EF 10 DRL. The protection plug is intended for installation in industrial and technical facilities where reliable protection against overvoltages is required.

Applications

The DRL RE 12 protection plug is particularly suitable for applications in industrial electrical engineering, where signal circuits with common reference potential are operated. This includes, for example, control and regulation systems, communication lines, as well as sensors and actuators in automated production environments. Use in DRL plug magazines enables modular and flexible integration into existing switchgear. The energetic coordination ensures that the protection plug reacts correctly in the event of overvoltage without damaging downstream devices.

Functions and Equipment in Detail

The protection plug features decoupling impedances that enable galvanic isolation between the connected lines and the protection device. This reduces the transmission of interference and increases the stability of signal circuits. The single-stage protection function means that the surge protection is installed directly at the end point of the signal circuit to ensure maximum protection effectiveness. Grounding is achieved via EF 10 DRL, enabling safe and reliable dissipation of overvoltages.

Technology Explained Simply

The DRL RE 12 protection plug operates on the principle of diverting overvoltages through a diverter that activates when a defined voltage threshold is exceeded. The decoupling impedances ensure that signal circuits are electrically separated from each other, minimizing interference. Energetic coordination means that the protection plug is matched in terms of energy absorption and dissipation with other protection components in the system, ensuring cascaded protection. Installation is exclusively in disconnectors or DRL plug magazines, enabling standardized and secure mounting.

Compatibility and Accessories

The protection plug is specifically designed for use in DRL plug magazines and disconnectors. It is energetically coordinated with other components of the DRL system, enabling safe integration into existing switchgear.

Mounting and Installation

Mounting is exclusively in disconnectors or DRL plug magazines. The protection plug is inserted into the designated socket and mechanically secured. No additional mounting aids or tools are required, as installation is simple and quick due to the plug-in technology. Installation is typically performed by qualified specialists as part of electrical installation.

Advantages in Operation

The DRL RE 12 protection plug provides reliable protection of signal circuits against overvoltages, particularly in environments with common reference potential. The decoupling impedances reduce interference and improve signal quality. Energetic coordination ensures safe and efficient protection function throughout the system. The modular design enables flexible expansion and maintenance of the switchgear. Installation in DRL plug magazines or disconnectors ensures standardized and secure mounting, improving the maintainability and expandability of the installation.

General
Degree of protectionIP 20 (when plugged in)
Power throughput12 kA
Groundingvia EF 10 DRL
Compatibilityfor disconnecting strips or DRL plug-in magazine
Decouplingwith decoupling impedances
Energy coordinationelectrically coordinated with DRL plug-in module
SPD classO
Nominal voltage (UN)12 V
Max. continuous operating voltage DC (UC)14 V
Max. continuous operating a.c. voltage (UC)9.5 V
Nominal current (IN)0.4 A
D1 Total lightning impulse current (10/350 µs) in combination with DRL 10 B... (Iimp)5 kA
D1 Lightning impulse current (10/350 µs) per line in combination with DRL 10 B... (Iimp)2.5 kA
C2 Total nominal discharge current (8/20 µs) in combination with DRL 10 B... (In)10 kA
C2 Nominal discharge current (8/20 µs) per line in combination with DRL 10 B... (In)5 kA
C1 Nominal discharge current (8/20 µs) per line without DRL 10 B... (In)0.5 kA
Voltage protection level line-PG for Iimp D1 in combination with DRL 10 B... (UP)≤ 45 V
Voltage protection level line-line at 1 kV/µs C3 (UP)≤ 36 V
Voltage protection level line-PG at 1 kV/µs C3 (Up)≤ 19 V
Series impedance per line4.7 ohms
Cut-off frequency line-PG (fG)2.7 MHz
Capacitance line-line (C)≤ 1 nF
Capacitance line-PG (C)≤ 2 nF
Operating temperature range (TU)-40 °C ... +80 °C
Pluggable intoLSA disconnection block 2/10 or DRL 10 B ... plug-in SPD block
Earthing viaearthing frame
Enclosure materialpolyamide PA 6.6
Colouryellow
Test standardsIEC 61643-21 / EN 61643-21


Product data sheet
Datasheet for DEHN 907421, EAN: 4013364107618

Questions & answers

What is the delivery time of Surge arrester 907421 Dehnrapid LSA protection class DRL RE 12?

The article Surge arrester 907421 Dehnrapid LSA protection class DRL RE 12 is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of DEHN 907421 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Surge arrester 907421 Dehnrapid LSA protection class DRL RE 12 always at the best possible price. We can give you a discount of 2% on Surge arrester 907421 Dehnrapid LSA protection class DRL RE 12 if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 pieces of Surge arrester 907421 Dehnrapid LSA protection class DRL RE 12 we can offer you a price of 45,64 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x DEHN 907421 surge arrester DRL RE 12
Surge arrester 907421 Dehnrapid LSA protection class DRL RE 12
48,55 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: DEHN 907421 surge arrester DRL RE 12
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
8 + 2 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.