Chauvin Arnoux P01700110 Michaelis buffer solution Redox (ORP) 146 mV (125 ml)
|
42,30 EUR |
|||||||||||
|
( 50,34 EUR incl. VAT ) ≈ £35.28 | ≈ $47.25 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Lieske Part No.: | 1142686 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | P01700110 | ||||||||||
| UPC/EAN: | 3663653007443 | ||||||||||
| Weight: | 0.123 kg | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Chauvin Arnoux P01700110:
Redox buffer solution
The Michaelis solution 146 mV is a specific buffer solution designed for the calibration of ORP sensors and devices. Redox potential (ORP) is a measure of the oxidizing and reducing capacity of a solution, and precise calibration of measuring devices is essential for reliable results in laboratory and industrial applications. The solution provides a stable reference value of 146 mV, used for setting and checking devices.
Applications
This buffer solution is primarily used in water analytics, process monitoring, and laboratory environments where accurate measurement of redox potential is required. It serves as a calibration standard for devices used in wastewater treatment, drinking water monitoring, or the chemical industry. The use of a standardized solution such as the Michaelis solution 146 mV enables reproducible and comparable measurements across different devices and locations.
Features and equipment in detail
The solution is packaged in a 125-mL bottle designed for safe transport and practical handling. The bottle is suitable for use in laboratory and industrial environments and allows precise dispensing of the required amount. The concentrated form of the solution typically requires dilution according to the device manufacturer’s instructions to achieve the correct calibration value.
Technology explained simply
The Michaelis solution 146 mV is based on a chemical buffer system that maintains a constant redox potential of 146 mV. This value is achieved through the specific composition of the solution and is independent of minor fluctuations in ambient temperature or concentration. The solution serves as a reference to detect deviations in measuring devices and correct them if necessary. Calibration is performed by immersing the ORP sensor in the solution and comparing the displayed value with the target value of 146 mV.
Compatibility and accessories
The Michaelis solution 146 mV is compatible with all ORP measuring devices requiring calibration with a defined redox standard. It can be used in combination with other calibration solutions, such as the Michaelis solution 500 mV or 800 mV, to cover a broader calibration range. Use is according to the instructions of the respective measuring device manufacturer.
Mounting and installation
The solution requires no mounting or installation. It is taken directly from the bottle and placed into a suitable container or directly into the measuring device, depending on the device manufacturer’s instructions. The bottle is designed to protect the solution during transport and storage.
Advantages in operation
The use of the Michaelis solution 146 mV ensures high measurement accuracy and reproducibility. The standardized concentration and defined redox value enable quick and reliable calibration. The 125-mL packaging provides sufficient quantity for multiple calibrations, making device maintenance more efficient. The solution is designed for use in professional environments and supports compliance with quality standards in analytics.
| General | |
| Redox potential | 146 mV |
Questions & answers
What is the delivery time of Chauvin Arnoux P01700110 Michaelis buffer solution Redox (ORP) 146 mV (125 ml)?
The article Chauvin Arnoux P01700110 Michaelis buffer solution Redox (ORP) 146 mV (125 ml) is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Chauvin Arnoux P01700110 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Chauvin Arnoux P01700110 Michaelis buffer solution Redox (ORP) 146 mV (125 ml) always at the best possible price. We can give you a discount of 2% on Chauvin Arnoux P01700110 Michaelis buffer solution Redox (ORP) 146 mV (125 ml) if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 pieces of Chauvin Arnoux P01700110 Michaelis buffer solution Redox (ORP) 146 mV (125 ml) we can offer you a price of 41,98 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
Chauvin Arnoux P01710011 CA 10101E pH meter for laboratory with analog output
The Chauvin Arnoux CA 10101E is a laboratory pH meter developed for electrochemical measurements in laboratory environments. It is used to determine the pH value, redox potential (ORP), and ...Lieske Part No.: 1142701 Mfg Part No: P01710011 |
537,30 EUR
![]() ≈ £448.11 | ≈ $600.16
On order · Delivery time approx. 20 workdaysinfo_outline
|