Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
Chauvin Arnoux Logo

Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml)

Your rating:
Average rating
product review for Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml)
( 4.5 / 5 ) 2 ratings
Chauvin Arnoux P01700108
This image may differ from the desired article.
12,84 EUR
( 15,28 EUR incl. VAT )
≈ £10.71  |  ≈ $14.34
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml)
Lieske Part No.:1927940
Mfg Part No: P01700108
UPC/EAN: 3663653006729
Weight:0.123 kg
Graduated prices net
From piecesPrice per pieces
1512,74 EUR
3012,65 EUR
7012,55 EUR
10012,45 EUR

Product information for Chauvin Arnoux P01700108:

The NIST-pH buffer solution pH 9.18 from Chauvin Arnoux is a high-precision reference material specifically developed for the calibration and fine-tuning of pH meters and measuring electrodes. The solution ensures a defined pH value of 9.18 at a temperature of 25°C, with a maximum deviation of ± 0.02. This high accuracy makes it particularly suitable for applications in laboratories and industrial environments where reliable and reproducible measurement is required. The buffer solution is traceable to international standards, highlighting its suitability for calibrated measurement processes and quality controls. The ready-to-use solution is delivered in a 125-ml bottle and is immediately usable without additional preparation or dilution.

Applications

The buffer solution pH 9.18 is primarily used for calibrating pH measuring devices, especially in applications covering the alkaline pH range. It serves as a reference point to check the accuracy and stability of measuring electrodes and pH meters. Typical use cases include laboratory environments, the food industry, chemical production, or environmental analysis, where precise pH values are critical. Traceability to international standards enables consistent measurement practices and is often a requirement for certified quality management systems.

Functions and Equipment in Detail

The solution is packaged in a convenient 125-ml bottle, ensuring safe transport and easy handling. The packaging is designed to protect the solution from contamination and evaporation. An official reference material certificate is included in the delivery scope, confirming the traceability and specific characteristics of the solution. This certificate serves as documented proof of the quality and suitability of the buffer solution in quality-controlled processes.

Technology Explained Simply

The pH value of 9.18 lies in the alkaline range of the scale and serves as a reference point for measuring devices operating in this range. The low tolerance of ± 0.02 ensures that the solution functions as a precise calibration method. Traceability means that the production and calibration of the solution are linked to international standards, ensuring comparability and reliability of measurement results across different laboratories and devices. The solution is ready-to-use, meaning it can be directly applied from the bottle into the measuring device without requiring dilution or further preparation.

Compatibility and Accessories

The buffer solution is universally compatible with pH meters and measuring electrodes designed for calibration with standard buffer solutions. It can be used in combination with other buffer solutions of different pH values (e.g. pH 4.01, pH 7.00) to create a complete calibration profile. The solution is used directly from the bottle, with the quantity varying depending on the device type and the manufacturer’s instructions. No special accessories or tools are required to use the solution.

Mounting and Installation

The buffer solution requires no mounting or installation. It is applied directly from the bottle into the measuring device, following the instructions of the respective pH meter or measuring electrode. The bottle is designed for easy opening and closing to ensure shelf life after opening.

Operational Advantages

Using the NIST-pH buffer solution pH 9.18 ensures high measurement accuracy and reproducibility. Traceability to international standards increases the acceptance of measurement results in certified environments. The long shelf life of 18 months before opening and 2 months after opening reduces consumption and the need for frequent reordering. The included certificate enables documented quality assurance, which is particularly important in industrial and laboratory settings.

Delivery Scope

The delivery scope includes 1 x NIST-pH buffer solution in a 125-ml bottle and 1 x official reference material certificate. The solution is ready-to-use and immediately applicable.

General
pH value9,18 bei 25°C
Shelf life after opening2 Monate


Questions & answers

What is the delivery time of Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml)?

The article Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml) is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Chauvin Arnoux P01700108 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml) always at the best possible price. We can give you a discount of 2% on Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml) if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 15 pieces of Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml) we can offer you a price of 12,74 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


This product is recommended as accessory for

Chauvin Arnoux P01710011 CA 10101E pH meter for laboratory with analog output Chauvin Arnoux LogoChauvin Arnoux P01710011 CA 10101E pH meter for laboratory with analog output The Chauvin Arnoux CA 10101E is a laboratory pH meter developed for electrochemical measurements in laboratory environments. It is used to determine the pH value, redox potential (ORP), and ...

Lieske Part No.: 1142701
Mfg Part No: P01710011
537,30 EUR
Chauvin Arnoux P01710011 plus VAT
≈ £448.11  |  ≈ $600.16
On order · Delivery time approx. 20 workdaysinfo_outline
Chauvin Arnoux P01710010 pH meter Chauvin Arnoux LogoChauvin Arnoux P01710010 pH meter The portable pH meter CA 10101 from Chauvin Arnoux is a measuring instrument for determining the pH value, redox potential (ORP), and temperature in aqueous solutions. It is designed for use in ...

Lieske Part No.: 1927943
Mfg Part No: P01710010
657,58 EUR 680,63 EUR
Chauvin Arnoux P01710010 plus VAT
≈ £548.42  |  ≈ $734.52
On order · Delivery time approx. 20 workdaysinfo_outline
Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Chauvin Arnoux P01700108 buffer solution pH 9.18 DIN-NIST 125 ml
Chauvin Arnoux P01700108 Buffer solution pH 9.18 DIN-NIST (125 ml)
12,84 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Chauvin Arnoux P01700108 buffer solution pH 9.18 DIN-NIST 125 ml
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
2 + 7 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.