Böhm Kabel 377005002 RD-Y(ST)Y 2x2x0.5 mm² grey cable for telecommunications
|
1,42 EUR |
|||||||||||
|
incl. 0,28 EUR copper surcharge ( 1,69 EUR incl. VAT ) ≈ £1.19 | ≈ $1.56 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Lieske Part No.: | 318290 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | 377005002 | ||||||||||
| Weight: | 0.06 kg | ||||||||||
| Type: | RD-Y(ST)Y2X2X0,5GR | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Böhm Kabel 377005002:
Applications
This cable is used in systems where reliable and interference-free signal transmission is required, for example in building automation, automation systems, exhibition construction, or industrial control systems. It is not intended for high-voltage installation purposes, as the operating peak voltage is maximum 600 V. Installation takes place indoors, where ambient conditions must not exceed temperature limits of -40 °C to +70 °C (non-moving) and -5 °C to +50 °C (moving).
Functions and Equipment in Detail
The cable consists of two pairs, each made of a bare, 7-strand copper wire. The core insulation is made of polyvinyl chloride (PVC), with cores marked in different colors according to VDE 0815 to enable clear identification. The pairs are arranged in a bundled stranding, ensuring low capacitive coupling and high crosstalk attenuation. The cable features a filler element made of aluminum-laminated foil material with an underlying drain wire, which increases mechanical stability and supports shielding effectiveness.
Technology Explained Simply
The cable shielding is achieved through an aluminum-laminated foil with a drain wire, providing electromagnetic shielding. This reduces interference from external electromagnetic fields and ensures clear signal transmission. The characteristic impedance is approximately 370 Ohm at 1 kHz and 130 Ohm at 10 kHz, ensuring stable impedance matching in data transmission systems. The cable attenuation is approximately 1.2 dB/km at 1 kHz and 3.0 dB/km at 10 kHz, helping to maintain signal quality over long distances. Crosstalk attenuation is at least 60 dB for a cable length of 500 m and 10 kHz, ensuring minimal signal interference between cores.
Compatibility and Accessories
The cable is designed for use in systems requiring interference-free data transmission. It is compatible with other telecommunications and installation cables that meet the same electrical and mechanical requirements. Use in combination with suitable connectors, cable lugs, or cable glands is possible, provided these meet the mechanical and electrical requirements of the cable.
Installation and Mounting
The cable is intended for fixed installation. The minimum bending radius is approximately 7.5 times the cable diameter to avoid mechanical damage. Installation takes place indoors, where ambient temperature must not exceed the specified limits. The cable is not suitable for use in the ground or outdoors without UV protection.
Operational Advantages
The cable construction ensures high mechanical stability and good electrical performance. The PVC insulation and PVC outer sheath provide sufficient mechanical and chemical resistance. Flame retardancy according to VDE 0482-332-1-2/IEC 60332-1 reduces fire risk in case of short circuit. Low cable attenuation and high crosstalk attenuation ensure clear signal transmission over long distances. Shielding minimizes electromagnetic interference, increasing data transmission reliability.
Protection Class and Environmental Conditions
The cable is not intended for outdoor use without UV protection, as the PVC outer sheath ages under UV exposure. Operating temperature ranges are clearly defined: -5 °C to +50 °C for moving installation and -40 °C to +70 °C for fixed installation. The cable is not suitable for use in the ground, as it is not protected against ground moisture or mechanical stress in soil.
Electrical Specifications
The maximum conductor resistance is 73.6 Ohm/km, ensuring low voltage drop during signal transmission. The test voltage is 2000 V between cores and 1000 V between core and shield. The insulation resistance is at least 100 MOhm × km, both between cores and between core and shield. The operating capacitance is maximum 120 nF/km at 800 Hz, with a 20% overrun allowed for cables with up to 4 pairs. Capacitive coupling is limited to maximum 200 pF/100 m at 800 Hz, with at least one value allowed to reach 400 pF.
Flame Retardancy
The cable meets the requirements of standard VDE 0482-332-1-2/IEC 60332-1, ensuring flame retardant properties during vertical installation. This reduces the risk of flame propagation in case of fire.
| General | |
| Conductor resistance | 73,6 Ohm/km |
| Temperature range in motion | -5 °C to +50 °C |
| Temperature range, non-operating | -40 °C to +70 °C |
| Operating peak voltage | 600 V |
| Test voltage core/core | 2000 V |
| Test voltage core/shield | 1000 V |
| Installation resistance core/core | 100 MOhm x km |
| Installation resistance core/shield | 100 MOhm x km |
| Operating capacity | 120 nF/km |
| Characteristic impedance at 1 kHz | 370 Ohm |
| Characteristic impedance at 10 kHz | 130 Ohm |
| Capacitive coupling | 200 pF/100 m |
| Cable attenuation at 1 kHz | 1,2 dB/km |
| Cable attenuation at 10 kHz | 3,0 dB/km |
| Side talk attenuation | 60 dB |
| Minimum bending radius | 7,5 x cable diameter |
| Flame retardancy | VDE 0482-332-1-2/IEC 60332-1 |
| Core identification | multicoloured, according to VDE 0815 |
| Conductor | bare Cu stranded wire, 7-strand |
| Wire insulation | PVC |
| Stranding | pairs in bundled stranding |
| Filling element | aluminium-clad foil with drain wire |
| Outer sheath | PVC |
The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.
Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
Questions & answers
What is the delivery time of Böhm Kabel 377005002 RD-Y(ST)Y 2x2x0.5 mm² grey cable for telecommunications?
The article Böhm Kabel 377005002 RD-Y(ST)Y 2x2x0.5 mm² grey cable for telecommunications is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Böhm Kabel 377005002 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Böhm Kabel 377005002 RD-Y(ST)Y 2x2x0.5 mm² grey cable for telecommunications always at the best possible price. We can give you a discount of 2% on Böhm Kabel 377005002 RD-Y(ST)Y 2x2x0.5 mm² grey cable for telecommunications if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 50 meters of Böhm Kabel 377005002 RD-Y(ST)Y 2x2x0.5 mm² grey cable for telecommunications we can offer you a price of 1,37 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

