Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

MED N 1000 VA 230V Trenntransformator

Your rating:
Average rating
product review for MED N 1000 VA 230V Trenntransformator
( 0 / 5 ) 0 ratings
10.798,92 EUR
( 12.850,71 EUR incl. VAT )
≈ £8,995.50  |  ≈ $11,846.42
plus delivery charges: 148,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x MED N 1000 VA 230V Trenntransformator
Lieske Part No.:995898
Mfg Part No: 2005741
Weight:14 kg

Product information for 2005741:

The product is a medical isolation transformer of the MED N series, designed for use in medical facilities in Europe. It provides galvanic isolation of electrical equipment in the medical field to ensure patient safety. The devices operate with a fixed primary and secondary alternating voltage of 230 V and are designed for continuous operation. Safety requirements according to DIN EN 60601-1 (Medical electrical equipment) are met, making use in clinical environments permissible.

Applications
The isolation transformer is intended for use in medical rooms where electrical equipment is connected to patients. It enables the supply of up to nine cold appliances via the output sockets. Galvanic isolation protects patients and operating personnel from dangerous touch voltages. The devices can also be used in rooms where no additional special medical equipotential bonding is installed, as the protective earth conductor of the input socket is connected to the contacts of the output sockets, ensuring basic equipotential bonding.

Functions and Equipment in Detail
The transformer features an integrated semiconductor-based inrush current limiter, preventing unwanted tripping of fuses in the device or in the building's sub-distribution due to inrush current. Short-circuit protection is ensured by a primary fine fuse. Additionally, overtemperature protection is integrated via a thermal switch in the primary winding, preventing damage from overheating. The devices are equipped with one or two equipotential bonding bolts, which can be connected to a special medical equipotential bonding in the application room according to DIN 42801.

Technology Explained Simply
Galvanic isolation is achieved through the transformer, which transfers electrical energy between primary and secondary sides via magnetic coupling without direct electrical connection. This minimizes the risk of electric shock in case of network or device faults. Leakage current values are below 100 µA at 230 V, meeting safety requirements for medical applications. The housing is made of sheet steel and is powder-coated in light grey RAL7035, providing a robust and easy-to-clean surface.

Compatibility and Accessories
The transformer is designed to supply medical cold appliances connected via sockets. The primary mains supply cable is included in the delivery scope. The devices comply with standards EN60601-1:2007 and EN60601-1-1:2007, ensuring compatibility with modern medical safety requirements. A declaration of conformity according to EU Directive 93/42/EEC and DIN EN 60601-1 is also part of the equipment.

Mounting and Installation
Installation is typically carried out at a suitable location in the medical room, with the mains supply cable connected to a wall socket. The output sockets are intended for direct connection to medical devices. Connection to equipotential bonding is made via the existing bolts, if a special medical equipotential bonding is installed in the room. The devices are designed for continuous operation and require no special mounting aids.

Advantages in Operation
Operating the isolation transformer ensures high safety for patients and operating personnel. Integrated protection functions such as inrush current limitation, short-circuit protection, and overtemperature protection increase reliability. Galvanic isolation enables use in rooms without additional equipotential bonding, increasing operational flexibility. The robust construction and durable design ensure a long service life.

General
Power1000 VA
Primary and secondary voltage230 V
Leakage current at 230V< 100 µA
Number of refrigeration units, connector9
Degree of protectionDIN EN 60601-1
Inrush current limitationThermal semiconductor
Short-circuit protectionFine fuse primary
Overtemperature protectionThermal switch
HousingSheet steel, powder-coated, light grey RAL7035
Primary power cableincluded in delivery
Conformity declarationin accordance with EC directives 93/42/EEC / DIN EN 60601-1
OperationContinuous operation


Questions & answers

What is the delivery time of MED N 1000 VA 230V Trenntransformator?

The article MED N 1000 VA 230V Trenntransformator is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of 2005741 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you MED N 1000 VA 230V Trenntransformator always at the best possible price. We can give you a discount of 2% on MED N 1000 VA 230V Trenntransformator if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x 2005741
MED N 1000 VA 230V Trenntransformator
10.798,92 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: 2005741
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
5 + 6 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.