The SD1K safety relay provides a certified safety solution for implementing emergency stop functions and other safety-critical controls. Certified up to PL e, Category 4, and SILCL 3, it meets the highest safety standards. The SD1K is type-tested for combustion plants in accordance with EN 50156-1 and EN 746-2 and supports Stop Category 0 according to EN 60204-1.
Its compact design with a width of only 6.8 mm saves valuable space in the control cabinet. At the same time, extensive diagnostics via front-facing LEDs enable quick error detection and troubleshooting.
Technical Data:
- Safety Certifications: - Certified up to PL e, Category 4, SILCL 3
- Inputs and Outputs: - 1 safe relay contact (13-14) that closes when the control voltage (A1/A2) is applied and opens immediately when the control voltage is switched off
- Housing and Design: - Housing width: 6.8 mm
- Error Monitoring: - Cyclical self-monitoring detects errors at the latest when the system is switched off and on again
- Feedback Loop (S21): - Terminal S21 allows for the integration of a feedback loop to monitor downstream contactors. This enables additional safety monitoring in accordance with regulatory standards.
- Safe Relay Contact (13-14): - The safe relay contact closes when the control voltage (A1/A2) is applied and opens immediately when the voltage is turned off. This function ensures reliable safety shutdowns.
- Signaling Output (C1): - The signaling output C1 switches inversely to the safe relay contact. This enables monitoring of the relay status. One possible use case is to detect errors, such as when the relay contact does not switch despite the control voltage being applied.
- Self-monitoring detects faults at the latest when the system is switched off and on again
- Single faults do not result in the loss of the safety function
- Type-tested for combustion plants according to EN 50156-1 / EN 746-2
- Supports Stop Category 0 according to EN 60204-1
- 1 signaling output (PNP) C1 that switches inverted to the safe relay contact
- 1 feedback loop (via terminal S21) for monitoring downstream contactors
- LED indicators for extensive diagnostics on the front of the device
- Ensures the safety function is maintained even if a single fault occurs
Functions:
Behavior in the Event of a Fault:
Scope of Delivery:
- 1x Safety Relay SD1K
- Connection instructions
- Warranty documents
Questions & answers
What is the delivery time of Zander Aachen ROTACAM P85, 2Ö/1S 1x M20 03079?
The article Zander Aachen ROTACAM P85, 2Ö/1S 1x M20 03079 is currently not in stock und muss auftragsbezogen bestellt werden.
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Zander Aachen ROTACAM P85, 2Ö/1S to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Zander Aachen ROTACAM P85, 2Ö/1S 1x M20 03079 always at the best possible price. We can give you a discount of 2% on Zander Aachen ROTACAM P85, 2Ö/1S 1x M20 03079 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.