Manufacturer no. Description Price Anzahl Bestellen
ABB 1SAM401922R1001ABB KA165 - terminal cover MS165/MO165 1SAM401922R1001 Terminal covers KA165 are used to increase the protection class to IP20 for MS/MO165Sales unit: 10 piecesLieske Part No.: 326531
60,39 EUR
ABB 1SNA115116R0700ABB M4/6 - Screw Clamp Terminal Blocks Feed Grey Feed-through terminal blocks with screw connection from the SNA series are available in widths from 5 mm to 36 mm. They can be snapped onto symmetrical and asymmetrical rails. They enable simple potential distribution with 3 or 4 independent connections. ABB's screw connection technology was developed to prevent the connections from coming loose due to vibrations, impacts or even accidental pulling on the cable. Thanks to the exclusive design, re-tightening the connections is no longer necessary in every case. They cover a connection requirement of 0.22 mm² to 240 mm². The screw connection technology allows up to two conductors to be connected per terminal, thus ensuring more flexibility in the control cabinet. Simple cable routing, as the conical opening guides the conductor precisely into the terminal cage.Sales unit: 50 piecesLieske Part No.: 760250
80,69 EURGraduated prices From pieces Price per pieces X 10 77,06 EUR 25 73,43 EUR 50 69,80 EUR 75 66,17 EUR
ABB 1SNA118368R1600ABB 1SNA118368R1600 - FEM6 Sections Grey FEM6 end plate 2.8mm, greySales unit: 100 piecesLieske Part No.: 175653
42,57 EURGraduated prices From pieces Price per pieces X 50 40,65 EUR 100 38,74 EUR 250 36,82 EUR 500 34,91 EUR
ABB 1SNA165130R2300ABB M16/12.P - Screw Clamp Terminal Blocks Ground Green Yellow M16/12.P Screw Clamp Terminal Blocks - Ground - Green-Yellow,16mm² RatedCrossSection, 12mm Spacing G32, TH 35-7.5, TH 35-15 RailLieske Part No.: 988206
3,54 EURGraduated prices From pieces Price per pieces X 50 3,38 EUR 100 3,22 EUR 250 3,06 EUR 500 2,90 EUR
ABB 1SVR405658R0000ABB CR-PM - Marker CR socket As an interface, interface relays connect the electronic control level, for example PLC, with the level of the sensors/actuators. They perform various functions: switching of direct or alternating voltage loads with different ohmic, inductive and capacitive components, switching in the voltage range from a few mV to 250 V, switching in the current range from a few mA to 16 A, amplifying weak control signals, potential isolation of control and load circuits and signal multiplication. The CR-P series has 9 different coil voltages with 1-2 changeover contacts. Two base variants are available: standard base and logical base. Pluggable function modules such as reverse polarity protection / freewheeling diode, LED module, RC elements, overvoltage protection or time modules expand the areas of application of the pluggable PCB relays.Lieske Part No.: 595393
0,11 EURGraduated prices From pieces Price per pieces X 50 0,11 EUR 100 0,10 EUR 250 0,10 EUR 500 0,09 EUR
ABB 2CCA880100R0001ABB CMS-100PS - Sensor 18mm 80A AC DC TRMS mounting pro compact & SMISSLINE The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and transmit these values to the InSite control unit via a 4-pin ribbon cable.
The sensors can be used with the protection and switching devices of the ABB System pro M compact® and enable installation in the rear terminal of the protection device. The closed solid-core sensors have a high measurement accuracy of 0.5% and are less sensitive to EMC effects from adjacent final circuits.Lieske Part No.: 875569
67,98 EURGraduated prices From pieces Price per pieces X 6 63,90 EUR 12 59,82 EUR 24 55,74 EUR 36 51,66 EUR
ABB 2CCA880101R0001ABB CMS-101PS - Sensor 18mm 40A AC DC TRMS mounting pro compact & SMISSLINE The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and transmit these values to the InSite control unit via a 4-pin ribbon cable.
The sensors can be used with the protection and switching devices of the ABB System pro M compact® and enable installation in the rear terminal of the protection device. The closed solid-core sensors have a high measurement accuracy of 0.5% and are less sensitive to EMC effects from adjacent final circuits.Lieske Part No.: 875562
67,98 EURGraduated prices From pieces Price per pieces X 6 63,90 EUR 12 59,82 EUR 24 55,74 EUR 36 51,66 EUR
ABB 2CCA880102R0001ABB CMS-102PS - Sensor 18mm 20A AC DC TRMS mounting pro compact & SMISSLINE The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and transmit these values to the InSite control unit via a 4-pin ribbon cable.
The sensors can be used with the protection and switching devices of the ABB System pro M compact® and enable installation in the rear terminal of the protection device. The closed solid-core sensors have a high measurement accuracy of 0.5% and are less sensitive to EMC effects from adjacent final circuits.Lieske Part No.: 875555
67,98 EURGraduated prices From pieces Price per pieces X 6 63,90 EUR 12 59,82 EUR 24 55,74 EUR 36 51,66 EUR
ABN 69993ABN 69993 - 69 993 terminal se 240qmm direct connection Al Cu 35 nm 185qmm Direct connection V-terminal 240mm² se, for AL + CU conductor 35-185mm² smLieske Part No.: 135268
26,33 EURGraduated prices From pieces Price per pieces X 15 25,54 EUR 30 24,75 EUR 70 23,96 EUR 100 23,17 EUR
ABN HK837CABN HK837C Cable house connection box K12,1x3xNH2/1Lieske Part No.: 483950
813,78 EURGraduated prices From pieces Price per pieces X 4 777,16 EUR 8 740,54 EUR 12 703,92 EUR 16 667,30 EUR
ABN HR044ABN HR044 - frame wall frame K3/K4 vorger Profilhalbzyl UP-frame wall frame for K3/K4, prepared for profile half cylinderLieske Part No.: 829720
533,61 EURGraduated prices From pieces Price per pieces X 5 509,60 EUR 10 485,59 EUR 15 461,57 EUR 20 437,56 EUR
ABN HS864CABN HS864C - cable service box K12 2x3xNH00 2x50 2x100A 185qmm Cable house connection box K12,2x3xNH00,2x50-185mm²,2x100ALieske Part No.: 253661
1.038,51 EURGraduated prices From pieces Price per pieces X 3 991,78 EUR 6 945,04 EUR 9 898,31 EUR 12 851,58 EUR
ABN SY450ATABN SY450AT - ZAS / STAS hood IP54 Tür 450mm ZAS/STAS accessories, hood IP54 with door for 450mm hLieske Part No.: 275031
218,79 EURGraduated prices From pieces Price per pieces X 5 212,23 EUR 10 205,66 EUR 15 199,10 EUR 20 192,54 EUR
Bachmann 317.000Bachmann 317.000 - Power Frame mounting frame 317 000 silver gray RAL 9006 short POWER FRAME installation frame 3-way, for installation in worktops, housing made of powder-coated sheet steel, color: white aluminum, RAL 9006, holder for socket insert, individually packed in a polybag. Please refer to the installation instructions at: www.bachmann.com/de/downloads for the dimensions.Lieske Part No.: 769453
42,97 EURGraduated prices From pieces Price per pieces X 15 41,04 EUR 30 39,10 EUR 70 37,17 EUR 100 35,24 EUR
Berker 1990Berker 1990 - dummy module 1 fold polar white Blind module, accessories, polar white. 1-way blind module for support plates for MINI-COM modules.Lieske Part No.: 996681
3,51 EURGraduated prices From pieces Price per pieces X 50 3,30 EUR 100 3,09 EUR 250 2,88 EUR 500 2,67 EUR
Cv KWE08GCv KWE08G Endplatte für KYA02LH3, KYA02LP, KYA02KD, Farbe: grau Verkaufseinheit: 1 ST.Lieske Part No.: 1354860
0,67 EUR
Cv KWE16BCv KWE16B Endplatte für KYA16NH2, Farbe: blau Verkaufseinheit: 1 ST.Lieske Part No.: 1354861
1,07 EUR
Cv KWE16GCv KWE16G Endplatte für KYA16LH2, Farbe: grau Verkaufseinheit: 1 ST.Lieske Part No.: 1354874
1,07 EUR
Dehn + Soehne 563019Dehn + Soehne 563019 - DEHN 563 019 terminal Fl 40mm PA Terminal block for universal combination with the terminal rail, rail brackets and covers. Version for connecting 1 conductor Fl up to 40 x 5 mm.Lieske Part No.: 686818
6,63 EURGraduated prices From pieces Price per pieces X 50 6,23 EUR 100 5,83 EUR 250 5,44 EUR 500 5,04 EUR
Doepke 09920104Doepke AS 25-Gi - power terminal spade design 09920104 Terminals for busbars for feeding into switching devices. The terminals of the AS series enable feeding into circuit breakers (single-pole+N). Properties: for 1+N-pole MCB, load capacity up to 80 A, Eurovario system.Lieske Part No.: 978842
2,57 EURGraduated prices From pieces Price per pieces X 50 2,45 EUR 100 2,34 EUR 250 2,22 EUR 500 2,11 EUR
Gustav Hensel 4012591111337Gustav Hensel FC N 10 - terminal FC 10 fixing DIN rail (top hat profile 35 mm) FIXCONNECT-N terminal 2 x 25 mm², 8 x 4 mm², Cu for mounting on a mounting rail.Lieske Part No.: 201407
9,41 EURGraduated prices From pieces Price per pieces X 25 8,99 EUR 50 8,56 EUR 100 8,14 EUR 250 7,72 EUR
Gustav Hensel 4012591111344Gustav Hensel FC PN 10 - Hensel FCPN10 plug terminal DIN rail Fixconnect f PE / conductor FIXCONNECT PE and N terminal each PE/N 2 x 25 mm², 4 x 4 mm², Cu for mounting on a mounting rail.Lieske Part No.: 589951
9,41 EURGraduated prices From pieces Price per pieces X 25 8,99 EUR 50 8,56 EUR 100 8,14 EUR 250 7,72 EUR
Gustav Hensel 4012591111368Gustav Hensel FC PE 10 - PE terminal fastening DIN rail (top hat profile 35 mm) FIXCONNECT-PE terminal 2 x 25 mm², 8 x 4 mm², Cu for mounting on a mounting rail.Lieske Part No.: 782872
9,41 EURGraduated prices From pieces Price per pieces X 25 8,99 EUR 50 8,56 EUR 100 8,14 EUR 250 7,72 EUR
Gustav Hensel 4012591122463Gustav Hensel DK KH 02 (4012591122463) Terminal holder for terminal type DK KL 02. Can be used in cable junction boxes DK 02..X, DK 02..XX, KF 02..X.Sales unit: 10 piecesLieske Part No.: 1586220
13,37 EUR
Gustav Hensel 4012591122470Gustav Hensel DK KH 04 (4012591122470) Terminal holder for terminal type DK KL 02 and DK KL 04. Can be used in cable junction boxes DK 04..X, DK 04..XX, KF 04..X.Sales unit: 10 piecesLieske Part No.: 1586206
13,37 EUR
Gustav Hensel 4012591122487Gustav Hensel DK KH 06 (4012591122487) Terminal holder for terminal type DK KL 02, DK KL 04 and DK KL 06. Can be used in cable junction boxes DK 06..X, DK 06..XX, DK 10..X, DK 10..XX, KF 06..X and KF 10..X.Lieske Part No.: 1586218
1,73 EUR
Gustav Hensel 4012591653318Gustav Hensel AS12 - Hensel 12 cover strips gray 12 modules 18 Cover strip
for sealing unused openings equipment, 12 modules each 18 mm. Type: AS12
Quantity: 1 unit.Lieske Part No.: 206726
4,31 EURGraduated prices From pieces Price per pieces X 50 4,12 EUR 100 3,92 EUR 250 3,73 EUR 500 3,53 EUR
Hager K116DHager K116D - Main branch terminal 16 ² Single box terminal 16mm², without mounting footLieske Part No.: 304094
2,62 EURGraduated prices From pieces Price per pieces X 50 2,46 EUR 100 2,31 EUR 250 2,15 EUR 500 1,99 EUR
Hager K28NHager K28N - Main branch terminal 4 pin 4 outlets 16 ² Main line branch terminal, 90SL, 4-pole, 80 A, 1.5-25 mm²Lieske Part No.: 883800
53,26 EURGraduated prices From pieces Price per pieces X 10 50,06 EUR 25 46,87 EUR 50 43,67 EUR 75 40,48 EUR
Hager K34AHager K34A - Contact protection cap, universZ, 90SL, for K37N, K46NLieske Part No.: 458841
6,44 EURGraduated prices From pieces Price per pieces X 50 6,05 EUR 100 5,67 EUR 250 5,28 EUR 500 4,89 EUR
Hager K54KHager K54K - control line terminal 7 pin 6qmm sealable Control line terminal, universal Z, 7-pole, up to 6 mm², with sealing cover. Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Rear knockout in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights 1100 and 1400 mm) and RfZ (for heights 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operationLieske Part No.: 249472
16,34 EURGraduated prices From pieces Price per pieces X 25 15,36 EUR 50 14,38 EUR 100 13,40 EUR 250 12,42 EUR
Hager K66AHager K66A - Main branch terminal 4 pin 35 ² 25 ² 12 Disposals Main line branch terminal 1x35mm²-2x25 mm²(pole 1 to 3), 1x35mm²-6x25mm² (pole 4)Lieske Part No.: 942100
67,12 EURGraduated prices From pieces Price per pieces X 10 63,09 EUR 25 59,07 EUR 50 55,04 EUR 75 51,01 EUR
Hager K96RHager K96R - CU busbar terminal UNIVERSN lowered = 1 5 70QMM Busbar terminal 6 - 70mm², for busbars 12x5mm, tier terminalLieske Part No.: 864872
22,08 EURGraduated prices From pieces Price per pieces X 15 20,76 EUR 30 19,43 EUR 70 18,11 EUR 100 16,78 EUR
Hager K96XHager K96X - busbar terminal 6 ² Busbar terminal 1.5-4mm², for PE-N rail UM29A 6x6mm, for Cu conductorsLieske Part No.: 703924
0,91 EURGraduated prices From pieces Price per pieces X 50 0,86 EUR 100 0,80 EUR 250 0,75 EUR 500 0,69 EUR
Hager KH23CHager KH23C - Main branch terminal 3 pole 25 ² 25 ² 4 outlets BGVA2 Main line terminals
Per pole with four clamping points,
solid / stranded 1.5 to 25 mm ².
stranded (with ferrule) 1.5 - 16 mm ²
Number of positions: 3-pin, finger-safe
Type: KH23C
Quantity: 1 unit.Lieske Part No.: 236791
23,17 EURGraduated prices From pieces Price per pieces X 15 21,78 EUR 30 20,39 EUR 70 19,00 EUR 100 17,61 EUR
Hager KH25CHager KH25C - Main branch terminal 5 pin 4 ² 25 378 020 Disposals BGVA2 The main line terminals with 4 pole terminal points, solid / stranded
, 5-25 mm ². stranded (with ferrule)
, 5 -
6 mm Number of pins: 5-pin, finger-safe type: KH25C item:
ST.Lieske Part No.: 942498
38,12 EURGraduated prices From pieces Price per pieces X 15 35,83 EUR 30 33,55 EUR 70 31,26 EUR 100 28,97 EUR
Hager KH35AHager KH35A - Main branch terminal 4 pin 25 ² 4 outlets 25/35 sqmm Main line branch terminal 4-pole, 2x35mm²-2x25mm² per pole, IP20, colour: greyLieske Part No.: 225262
59,90 EURGraduated prices From pieces Price per pieces X 10 56,31 EUR 25 52,71 EUR 50 49,12 EUR 75 45,52 EUR
Hager KH45AHager KH45A - Main branch terminal 5 pin 25 ² 5 outlets 25/35 sqmm Main line branch terminal 5-pole, 2x35mm²-2x25mm² per pole, IP20, 3x L, 1xPE, 1xNLieske Part No.: 830659
74,55 EURGraduated prices From pieces Price per pieces X 10 70,08 EUR 25 65,60 EUR 50 61,13 EUR 75 56,66 EUR
Hager KJ00ZHager KJ00Z - locking pin plug terminal counter Locking pin, univers Z, for meter plug terminalLieske Part No.: 304140
0,72 EURGraduated prices From pieces Price per pieces X 50 0,68 EUR 100 0,63 EUR 250 0,59 EUR 500 0,55 EUR
Hager KJ30THager KJ30T - AC terminal integrated lock leaving TRE Meter plug-in terminal, universZ, three-phase current 63 A, lockable, without TRE connection terminals. Meter plug-in terminal according to DIN VDE 0603-3, suitable for electricity meters according to DIN 43857, for the quick and safe replacement of electricity meters, nominal current: 63A, 3-pole, with 2nd connection for N conductor, terminal cross-section main line up to 25mm², color: RAL 9010, dimensions (LxWxH) = 130x40x32Lieske Part No.: 990338
108,01 EURGraduated prices From pieces Price per pieces X 6 101,53 EUR 12 95,05 EUR 24 88,57 EUR 36 82,09 EUR
Hager KJ31Z2Hager KJ31Z2 - AC plug pins 7x flexible counter = 45mm Plug pins, universZ, for meter plug terminal 100 A, 7 pieces, flexibleLieske Part No.: 892255
110,09 EURGraduated prices From pieces Price per pieces X 6 103,48 EUR 12 96,88 EUR 24 90,27 EUR 36 83,67 EUR
Hager KJ37ZHager KJ37Z - 100A sealing cover hard paper layer Sealing cap, universal Z, for all KJ31..Lieske Part No.: 300299
32,67 EURGraduated prices From pieces Price per pieces X 15 30,71 EUR 30 28,75 EUR 70 26,79 EUR 100 24,83 EUR
Hager KM05BHager KM05B PE/N terminal, universZ, 4x5 terminal points, 2x6/2x10/1x25mm², with clamp for 25 mm². Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Back knockout in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights of 1100 and 1400 mm) and RfZ (for heights of 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and make ready for operation.Lieske Part No.: 645149
24,16 EURGraduated prices From pieces Price per pieces X 15 22,71 EUR 30 21,26 EUR 70 19,81 EUR 100 18,36 EUR
Hager KM10EHager KM10E - PE terminal 2x16 8x10 sqmm Snap-on PE and N terminals
For plugging onto rail 12 x 2 mm or 35 mm DIN rail
Termination: PE
Length: 75 mm
Connections: 10
Type: KM10E
Quantity: 1 unit.Lieske Part No.: 263314
15,05 EURGraduated prices From pieces Price per pieces X 25 14,15 EUR 50 13,24 EUR 100 12,34 EUR 250 11,44 EUR
Hager KM11NHager KM11N - terminal 5x16/6x10qmm 11 terminal points Brass terminal, NZ meter panel, N, 11 terminal pointsLieske Part No.: 121215
5,74 EURGraduated prices From pieces Price per pieces X 50 5,40 EUR 100 5,05 EUR 250 4,71 EUR 500 4,36 EUR
Hager KM13EHager KM13E - PE terminal 6x16 7x10 sqmm Brass terminal, NZ meter panel, PE, 13 terminal pointsLieske Part No.: 316570
6,44 EURGraduated prices From pieces Price per pieces X 50 6,05 EUR 100 5,67 EUR 250 5,28 EUR 500 4,89 EUR
Hager KM17NHager KM17N - terminal 1x25 8x16 8x10 sqmm Brass terminal, NZ meter board, N, 17 terminal pointsLieske Part No.: 815441
10,30 EURGraduated prices From pieces Price per pieces X 50 9,68 EUR 100 9,06 EUR 250 8,45 EUR 500 7,83 EUR
Hager KM22AHager KM22A PE/N terminal, universal Z, 2x22 terminal points, 10x16/12x10 mm². Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Back knockout in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights of 1100 and 1400 mm) and RfZ (for heights of 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operation.Lieske Part No.: 618691
36,33 EURGraduated prices From pieces Price per pieces X 15 34,15 EUR 30 31,97 EUR 70 29,79 EUR 100 27,61 EUR
Hager KR15PHager KR15P - Series connection terminal 35-150mm², grey. Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimension standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with a door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Rear pre-punching in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights 1100 and 1400 mm) and RfZ (for heights 1100 mm). Door flush with the front with internal, adjustable hinges, can be hinged on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other and one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted from below or from the side into the lower connection compartment of the meter cabinet and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operation.Lieske Part No.: 341353
94,94 EURGraduated prices From pieces Price per pieces X 10 89,24 EUR 25 83,55 EUR 50 77,85 EUR 75 72,15 EUR
Hager KR95PHager KR95P - series terminal 1 pole 25 95 sqmm Series connection terminal 25-95mm², grey. Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimension standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with a door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Rear pre-punching in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights 1100 and 1400 mm) and RfZ (for heights 1100 mm). Door flush with the front with internal, adjustable hinges, can be hinged on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other and one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted from below or from the side into the lower connection compartment of the meter cabinet and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operation.Lieske Part No.: 194333
78,21 EURGraduated prices From pieces Price per pieces X 10 73,52 EUR 25 68,82 EUR 50 64,13 EUR 75 59,44 EUR