| General |
| Frequency range | 2000 MHz |
| Connection | RJ45 |
| Cable category | CAT 8.1 |
| Scope of delivery | 2 Permanent Link Adapters, reference cable, calibration adapter |
The RJ45 CAT 8.1 Permanent Link test adapter from Softing IT Networks is a specialised test accessory for inspecting copper cabling in the field of network technology. It is designed for precise measurement of Permanent Link connections, i.e. the direct connection between two endpoints of a network cable run, without additional plug connections in the measurement path. The device is designed for use with network testers that support CAT 8.1 standard requirements, and enables precise diagnostics at frequencies up to 2000 MHz. The measurement is performed via an RJ45 connector, designed for connection to standard network cables and devices.
Permanent Link test adapter enables precise analysis of cable quality by measuring the physical properties of the connection directly at the endpoints. This is particularly important for the installation and maintenance of high-speed networks, where even minor errors in cabling can lead to signal loss or data transmission disruptions. The adapter is part of a complete kit required for carrying out professional cable tests.
Functions and equipment in detail
The kit includes two Permanent Link adapters, a reference cable, and a calibration adapter. The two Permanent Link adapters are connected to the ends of the cable run to be tested, in order to measure the actual performance of the connection. The reference cable serves as a comparison standard to calibrate the measuring instruments against a known reference. The calibration adapter enables calibration of the measurement system to minimise systematic errors and ensure the accuracy of measurement results. These components are necessary to perform measurements in accordance with applicable standards.
Technology explained simply
The measurement is performed in the frequency range up to 2000 MHz, which corresponds to the requirements of the CAT 8.1 standard category. This frequency range is necessary to check the performance of modern network cables at high data rates. The use of RJ45 connectors ensures compatibility with common network devices and cables. The measurement is performed via the cable itself, with the adapters capturing signals directly at the endpoints, without additional plug connections in the measurement path. This avoids error sources that could arise from additional connections.
Compatibility and accessories
The test adapter is specifically designed for use with network testers that support CAT 8.1 standard requirements. It is not intended for other categories such as CAT 6A or CAT 7A, as the frequency and impedance requirements differ. Compatibility is oriented towards devices that perform Permanent Link measurements according to applicable standards. The kit is to be used as a unit, with all components working together to enable correct measurement.
Installation and mounting
Installation is carried out by simply connecting the Permanent Link adapters to the ends of the cable run to be tested. The adapters are connected directly to the RJ45 plug connections, with the connection needing to be mechanically stable to avoid measurement errors. The reference cable and calibration adapter are used according to the instructions of the measuring device to perform calibration and referencing. The exact procedure depends on the software of the measuring device used.
The use of individual components without the complete kit is not intended and may lead to inaccurate measurement results.
Advantages in operation
The use of the Permanent Link test adapter enables precise and reliable evaluation of cable quality. The measurement is performed directly at the endpoints, capturing the actual performance of the connection. Calibration and referencing ensure consistent results that are comparable with other measurements. This is particularly important for the installation and maintenance of high-speed networks, where high reliability of cabling is required. The measurement is performed without additional plug connections, which increases accuracy and minimises error sources.