Product Description in English:
The MZM 100 ST2-1P2PWREM-A safety sensor is a highly reliable safety interlock with an inductive operating principle and universal coding, designed for securing protective devices in machines and systems. Compliant with EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-3, and EN IEC 61508, this sensor meets the highest functional safety requirements.
The sensor features integrated latching, locking monitoring, short-circuit and cross-circuit detection, and the ability to connect up to 31 devices in series. With two safe digital outputs and a diagnostic output, the sensor offers easy integration into existing safety systems. The LED status indicator provides users with immediate insights into the operational and fault status.
Technical Data:
Product Type:
Order Number:
EAN:
eCl@ss Numbers:
- Version 12.0: 27-27-26-03
- Version 11.0: 27-27-26-03
- Version 9.0: 27-27-26-03
ETIM Numbers:
- Version 7.0: EC002593
- Version 6.0: EC002593
Approvals:
Standards:
- EN ISO 13849-1
- EN ISO 14119
- EN IEC 60947-5-3
- EN IEC 61508
Coding:
Housing Material:
- Plastic, glass-fiber reinforced thermoplastic, self-extinguishing
Reaction Time:
Risk Time:
Gross Weight:
Features:
- Operating Current Principle: Yes
- Lock Monitoring: Yes
- Latching: Yes
- Short-Circuit Detection: Yes
- Cross-Circuit Detection: Yes
- Series Connection: Yes
Mechanical Data:
- Mechanical Life: at least 1,000,000 switching cycles
- Holding Force: typical 750 N, guaranteed 500 N
- Latching Force: 45 N to 115 N
Electrical Data:
- Operating Voltage: 24 VDC -15 % / +10 %
- No-Load Current: typically 100 mA
- Magnet Activation Current: 350 mA (average)
Indicator Lights:
Operating Status: Yellow LEDFault Condition: Red LEDPower Supply: Green LEDPin Assignment:
PIN 1: A1 Power Supply UbPIN 2: X1 Safety Input 1PIN 3: A2 GNDPIN 4: Y1 Safety Output 1PIN 5: OUT Diagnostic OutputPIN 6: X2 Safety Input 2PIN 7: Y2 Safety Output 2PIN 8: IN Magnet ControlScope of Delivery:
The actuator is not included.Accessories:
Recommended Actuator: MZM 100-B1.1Note:
The unlocked guard can be locked again as long as the actuator is in contact with the interlock. The safety outputs will be reactivated.