Product Description in English:
The MZM 100 ST2-1P2PWM-A safety sensor is a dependable safety interlock with an inductive operating principle and universal coding, making it ideal for use in safety-critical industrial applications. The sensor complies with EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-3, and EN IEC 61508, ensuring maximum protection for personnel and machinery.
With its locking monitoring, latching function, and short-circuit and cross-circuit detection, the sensor provides an effective solution for safeguarding protective devices. The sensor supports series connection of up to 31 devices and features LED status indicators for quick identification of operating and fault conditions. It has two safe digital outputs and one diagnostic output.
Technical Data:
Product Type:
Order Number:
EAN:
eCl@ss Numbers:
- Version 12.0: 27-27-26-03
- Version 11.0: 27-27-26-03
- Version 9.0: 27-27-26-03
ETIM Numbers:
- Version 7.0: EC002593
- Version 6.0: EC002593
Approvals:
Standards:
- EN ISO 13849-1
- EN ISO 14119
- EN IEC 60947-5-3
- EN IEC 61508
Coding:
Housing Material:
- Plastic, glass-fiber reinforced thermoplastic, self-extinguishing
Reaction Time:
Risk Time:
Gross Weight:
Features:
- Operating Current Principle: Yes
- Lock Monitoring: Yes
- Latching: Yes
- Short-Circuit Detection: Yes
- Cross-Circuit Detection: Yes
- Series Connection: Yes
Mechanical Data:
- Mechanical Life: at least 1,000,000 switching cycles
- Holding Force: typical 750 N, guaranteed 500 N
- Latching Force: 15 N
Electrical Data:
- Operating Voltage: 24 VDC -15 % / +10 %
- No-Load Current: typically 100 mA
- Magnet Activation Current: 350 mA (average)
Indicator Lights:
Operating Status: Yellow LEDFault Condition: Red LEDPower Supply: Green LEDPin Assignment:
PIN 1: A1 Power Supply UbPIN 2: X1 Safety Input 1PIN 3: A2 GNDPIN 4: Y1 Safety Output 1PIN 5: OUT Diagnostic OutputPIN 6: X2 Safety Input 2PIN 7: Y2 Safety Output 2PIN 8: IN Magnet ControlScope of Delivery:
The actuator is not included.Accessories:
Recommended Actuator: MZM 100-B1.1Note:
The unlocked guard can be locked again as long as the actuator is in contact with the interlock. The safety outputs will be reactivated.