Product Description in English:
The AZM 170-02ZRK 230VAC is an electromechanical safety switch designed to ensure the safety of personnel operating machinery. With a maximum holding force of 1,300 N and a robust, glass-fiber reinforced thermoplastic housing, it meets high safety standards. The device operates on the closed-circuit principle, supports up to two approach directions, and features two galvanically separated safety contacts. The cutting clamp connection technology allows for flexible wiring without additional ferrules.
Technical Data:
Product Type Designation:
Order Number:
EAN:
Approvals and Standards:
- Certifications: IFA, cULus, CCC
- Standards:
- EN ISO 13849-1
- EN ISO 14119
- EN IEC 60947-5-1
General Data:
- Coding Level per EN ISO 14119: Low
- Operating Principle: Electromechanical
- Housing Material: Plastic, glass-fiber reinforced thermoplastic
- Gross Weight: 272 g
- Closed-Circuit Principle: Yes
- Number of Approach Directions: 2
- Number of Safety Contacts: 2
Safety Considerations:
- Performance Level: Up to category c (single-channel) or d (two-channel with appropriate logic unit)
- Service Life: 20 years
- B10D NC Contacts: 2,000,000 operations
Mechanical Data:
- Mechanical Lifespan: At least 1,000,000 operations
- Holding Force (EN ISO 14119): 1,000 N
- Maximum Holding Force: 1,300 N
- Latching Force: 30 N
- Forced Opening Distance: 11 mm
- Maximum Actuation Speed: 2 m/s
- Mounting: Screws (2x M5, tightening torque 0.7–1 Nm, Torx T10)
Connection Technology:
- Cable Entry: 1 x M20 x 1.5
- Connection Type: Cutting clamp technology
- Conductor Cross-Section: 0.75–1 mm² (flexible)
Dimensions:
- Length: 30 mm
- Width: 90 mm
- Height: 84 mm
Environmental Conditions:
- Protection Class: IP67
- Operating Temperature: -25 ... +60 °C
- Relative Humidity: Non-condensing, non-freezing
- Safety Class: II
- Permissible Installation Height: Up to 2,000 m above sea level
Electrical Data:
- Rated Control Supply Voltage: 230 VAC
- Maximum Electrical Power Consumption: 12 W
- Switching Element: 2 NC, galvanically separated contact bridges
- Maximum Switching Frequency: 1,000/h
- Voltage Operating Category AC-15: 230 VAC / 4 A
- Voltage Operating Category DC-13: 24 VDC / 4 A
Additional Information:
- Application Areas:
- Sliding guards
- Removable guards
- Rotating guards
Scope of Delivery:
- Actuator not included
- Cover plate
Notes:
- Cutting clamp technology enables easy connection without ferrules.
- Manual release with triangular key M5 (available as an accessory).