Product description in English:
The magnetic safety sensor BNS 180-02Z is an ideal solution for monitoring protective devices in safety-critical applications. Made of fiberglass-reinforced thermoplastic, the robust housing provides high mechanical stability and is protected against dust and water ingress with an IP67 rating.
The sensor operates on a magnetic principle and features two normally closed (NC) contacts. With a lifespan of up to 25,000,000 switching cycles (B10D) and a service life of 20 years, it meets high safety standards according to EN ISO 13849-1. The BNS 180-02Z can be installed flush with the surface, simplifying installation.
The connection cable is 1 meter long and has a PVC sheath. The secured switching distances are up to 20 mm for ON" (Sao) and up to 32 mm for "OFF (Sar), depending on the actuator used.
Technical specifications:
Ordering information:
- Product designation: BNS 180-02Z
- Article number: 101133009
- EAN: 4030661279640
- eCl@ss number: 27-27-44-01
- ETIM number: EC002544
Approvals and standards:
- Certifications: cULus
- Standards: BG-GS-ET-14, EN IEC 60947-5-3
Mechanical specifications:
- Operating principle: Magnetic
- Dimensions: ISO thread M18, Length 36 mm
- Protection class: IP67
- Movement direction: Frontal to the active surface
- Switching distances:
- Sao: 10 mm / 20 mm
- Sar: 22 mm / 32 mm
- Lifespan: 25,000,000 switching cycles (B10D)
- Connection: Cable, 1 m length, PVC sheath, cross-section 0.25 mm² (23 AWG)
Electrical specifications:
- Switching voltage: max. 100 VAC / 100 VDC
- Switching current: max. 0.25 A
- Switching power: max. 3 W
- Switching elements: 2 normally closed (NC)
- Switching frequency: max. 5 Hz
Environmental conditions:
- Operating temperature: -25 °C to +70 °C
- Vibration resistance: 10–55 Hz, amplitude 1 mm
- Shock resistance: 30 g / 11 ms
Delivery:
- The actuator is not included in the scope of delivery.
Accessories:
- Recommended actuators: BP 6, BP 8, BP 10, BP 15 SS
- Recommended safety control units: SRB-E-301ST, SRB-E-201LC
Notes:
- The sensor must be installed concealed according to EN ISO 14119, preventing actuation with a magnet.
- Contact symbols are shown with the protective device in a closed state.